Siemens 6EP1334-7CA00 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Siemens 6EP1334-7CA00 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
© 3 Siemens, All rights reserved Ⓟ
PSU100P 01 .201- -6419, 06 4
SITOP PSU100
SITOP PSU100
SITOP PSU100
SITOP PSU100SITOP PSU100P
P
P
P P
6EP1333-
6EP1333-
6EP1333-
6EP1333-6EP1333-
7CA00 24 V / 5 A
7CA00 24 V / 5 A
7CA00 24 V / 5 A
7CA00 24 V / 5 A7CA00 24 V / 5 A
6EP1334-
6EP1334-
6EP1334-
6EP1334-6EP1334-7CA00 24 V / 8 A
7CA00 24 V / 8 A
7CA00 24 V / 8 A
7CA00 24 V / 8 A 7CA00 24 V / 8 A
Betriebs
Betriebs
Betriebs
BetriebsBetriebsanleitung (kompakt)
anleitung (kompakt)
anleitung (kompakt)
anleitung (kompakt)anleitung (kompakt)
Operating Inst
Operating Inst
Operating Inst
Operating InstOperating Instructions (compact)
ructions (compact)
ructions (compact)
ructions (compact)ructions (compact)
Notice de servic
Notice de servic
Notice de servic
Notice de servicNotice de service (compacte)
e (compacte)
e (compacte)
e (compacte)e (compacte)
Istruzi
Istruzi
Istruzi
IstruziIstruzioni operative (descrizione sintet
oni operative (descrizione sintet
oni operative (descrizione sintet
oni operative (descrizione sintetoni operative (descrizione sintetica)
ica)
ica)
ica)ica)
Instrucc
Instrucc
Instrucc
InstruccInstrucciones de servicio (resumidas)
iones de servicio (resumidas)
iones de servicio (resumidas)
iones de servicio (resumidas)iones de servicio (resumidas)
Bild 1: Ansicht Geräte
Figure 1: View of units
Figure 1: Vue des appareils
Figura 1: Vista degli apparecchi
Figura 1: Vista de aparatos
B ild 2: Maßbild
Figure 2: Dimensions
Figure 2: Dimensions
Figura 2: Dimensione
Figura 2: plano acotado
ENGLISH
ENGLISH
ENGLISH
ENGLISH ENGLISH
Descri
Descri
Descri
DescriDescription
ption
ption
ptionption
The PSU100P SITOP power supplies
are provided for Indoor and Outdoor
application, degree of protection IP67,
protection class I.
Primary switched-mode power supplies
for connection to 1-phase AC system
(TN, TT system in accordance with
VDE -0100 T 300 / IEC 364 3) with rated
voltages of 120/230 V, 50/60 Hz;
+24 V DC output voltage, isolated,
short-circuit-proof and idling-proof.
See also Figure 1
Safety not
Safety not
Safety not
Safety notSafety notes
es
es
eses
NOTIC
NOTIC
NOTIC
NOTICNOTICE
E
E
EE
Appropriate transport, proper storage,
mounting, and installation, as well as
careful operation and service, are
essential for the error-free, safe and
reliable operation of the device/system.
Setup and operation of this
device/system are permitted only if the
instructions and warnings of the
corresponding documentation are
observed.
Only qualified personnel are allowed to
install the device/system and set it into
operation.
Assembli
Assembli
Assembli
AssembliAssembling
ng
ng
ngng
Wall mounting.
The device must be mounted in such a
way that the input and output terminals
are at the bottom.
A clearance of at least 50 mm must be
maintained above and 20mm in front of
the device .
See Figurealso 2
See Figure also 4
Bild 3: Input â‘  â‘¡ Output , Meldekontakt â‘¢
Figure 3: Input â‘  â‘¡ Output , signaling contact â‘¢
Figure 3: Input â‘  â‘¡Output , contact de signalisation â‘¢
Figura 3: Input â‘  â‘¡ Output , contatto di segnalazione â‘¢
Figura 3: Entradas â‘ Salidas â‘¡, contacto de
señalización ③
Bild 4: ⑤ Freiraum für Kühlung
Figure 4: ⑤ Required clearance for cooling
Figure 4: ⑤ Espace libre pour refroidissement
Figura 4: ⑤ Spazio libero per raffreddamento
Figura 4: ⑤ Espacio libre para refrigeración
Connecti
Connecti
Connecti
ConnectiConnecting
ng
ng
ngng
WARNING
WARNING
WARNING
WARNINGWARNING
Before installation or maintenance work
can begin, the system's main switch
must be switched off and measures
taken to prevent it being switched on
again. If this instruction is not observed,
touching live parts can result in death or
serious injury. It is only permissible to
use an insulated screwdriver when
actuating the potentiometer. For
installation of the devices, the relevant
country-specific regulations must be
observed.
The supply voltage (1 AC 120/230 V)
must be connected in accordance with
IEC 60364 and EN 50178.
Instructio
Instructio
Instructio
InstructioInstructions for UL c
ns for UL c
ns for UL c
ns for UL cns for UL compliant
ompliant
ompliant
ompliantompliant use:
use:
use:
use: use:
The input/output connection is to be
made using UL-Listed (CYJV)
connector/cable combination with
minimum ratings of 300 V, 8 A, 60°C
operating temperature.
The signal connection is to be made
using UL-Listed (CYJV) connector/cable
combination with minimum ratings of
240 V, 4 A, 60°C operating
temperature.
Plug connector
Plug connector
Plug connector
Plug connectorPlug connectors
s
s
s s
are not
are not
are not
are not are not inc
inc
inc
incincluded
luded
luded
ludedluded
Input â‘ :
cable connector 7/8"-16UN 3 Pol.
E. Binder - - - g. 99 2440 12 03
Output â‘¡:
cable connector 7/8"- -Pol UN 4
E. Binder - - - g. 99 2443 12 04
Signaling Contact â‘¢:
cable connector M12, 4- Pol
E. Binder - - - g. 99 0429 14 04
See also Figure 3
Struct
Struct
Struct
StructStructure
ure
ure
ureure
â‘  AC input
â‘¡ DC output
â‘¢ Signaling contact
â‘£ Indicator light (24 V OK)
⑤ Clearance for cooling
â‘£
â‘  â‘¢ â‘¡
⑤
20
Bild 5: Derating
Figure 5: Derating
Figure 5: Déclassement
Figura 5: Derating
Figura 5 Reducción de potencia:
Input â‘ 
1
PE
2
L1
3
N
Output â‘¡
1
- (- 1)
2
- (- 2)
3
+ (+1)
4
+ (+2)
Meldekontakt, signaling contact â‘¢
Bild 6: Anschlussbelegung
Figure 6: Contact arrangement
Figure 6: Brochage
Figura 6: Schema dei contatti
Figura 6: Asignación de conectores
Operat
Operat
Operat
OperatOperating mod
ing mod
ing mod
ing moding mode
e
e
ee
Signaling
Signaling
Signaling
SignalingSignaling
⑤LED is green: Output voltage OK
Alarm signals
Alarm signals
Alarm signals
Alarm signalsAlarm signals
â‘¢Signaling contact: Output OK
Contact rating 30 V A, AC/0.5
30 V A DC/1
See also Figure 4
Techni
Techni
Techni
TechniTechnical da
cal da
cal da
cal dacal data
ta
ta
tata
6EP1333-7 CA00
24 V/5 A
6EP1334-7 CA00
24 V/8 A
â‘ Input var
Input var
Input var
Input varInput variables
iables
iables
iablesiables
Rated input voltage Uin rated:
1 AC 120/230 V 50/60 Hz
Voltage range:
1 AC - - V 85 132/170 264
Rated input current I
in rated :
At nominal load
2,3/1,3 A 3,6A/1,6 A
Input fuse: Internal
Recommended miniature circuit
breaker: Characteristic C or B min.: 6 A
Power consumption (active power) full
load (typical)
133 20 W 6 W
â‘¡Output variable
Output variable
Output variable
Output variableOutput variables
s
s
ss
Rated output voltage Uout rated :
24 24 V V
Rated output current Iout rated:
5 A 8 A
Ambient condit
Ambient condit
Ambient condit
Ambient conditAmbient conditions
ions
ions
ionsions
Temperature for operation:
- 25...+60 °C;
Natural convection.
No direct sunlight.
Derating
In Voltage Uin < 100 V output power
reduction depending on the ambient
temperature.
See Figure 5
Protective f
Protective f
Protective f
Protective fProtective function
unction
unction
unctionunction
Current limitation at permanent
overload <1,3 × IOUT rated
Characteristic of current limitation
constantly decreasing to 20V. Hiccup
mode below 20 V.
0
20
40
60
80
100
120
0 100 200 300
Power Rating [%]
Input Voltage [Vac]
Power Rating [%] 60°C
1 2
4 3
Dimensions
Dimensions
Dimensions
DimensionsDimensions
width × height × depth in mm:
120x155x61
mounting lug and
plugs not included
120x155x61
mounting lug and
plugs not included
SITOP I
SITOP I
SITOP I
SITOP ISITOP IP65/
P65/
P65/
P65/P65/67 Por
67 Por
67 Por
67 Por67 Portfol
tfol
tfol
tfoltfolio
io
io
ioio
- Function expansion possible
using DC (UPS500P) UPS
- Power supply PSU300P for
3ph connection
(3 AC 400 – 500V)
www.siemens.com/sitop
Disposal
Disposal
Disposal
DisposalDisposal guideli
guideli
guideli
guideli guidelines
nes
nes
nesnes
Packaging and packaging aids can and
must always be recycled. The product
itself may not be disposed of by means
of domestic refuse.
Servic
Servic
Servic
ServicService and Su
e and Su
e and Su
e and Sue and Support
pport
pport
pportpport
http://support.automation.siemens.com
Telephone: + 49 (0) 911 895 7222


Product specificaties

Merk: Siemens
Categorie: Niet gecategoriseerd
Model: 6EP1334-7CA00
Kleur van het product: Meerkleurig
Gewicht: 1100 g
Breedte verpakking: 185 mm
Diepte verpakking: 75 mm
Hoogte verpakking: 215 mm
Land van herkomst: Hongarije