Siemens 3RW5217-1AC15 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Siemens 3RW5217-1AC15 (11 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 183 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/11
Data sheet
Data sheet
Data sheet
Data sheetData sheet 3RW5217-1AC15
3RW5217-1AC15
3RW5217-1AC15
3RW5217-1AC153RW5217-1AC15
SIRIUS soft starter 200-600 V 38 A, 110-250 V AC Screw terminals
Analog output
Product brand name
Product brand name
Product brand name
Product brand nameProduct brand name SIRIUS
Product category
Product category
Product category
Product categoryProduct category Hybrid switching devices
Product designation
Product designation
Product designation
Product designationProduct designation Soft starter
Product type designation
Product type designation
Product type designation
Product type designationProduct type designation 3RW52
Manufacturer's article number
Manufacturer's article number
Manufacturer's article number
Manufacturer's article numberManufacturer's article number
● of HMI module usable 3RW5980-0HS00
● of HMI-Modul high-feature usable 3RW5980-0HF00
● of communication module PROFINET standard
usable
3RW5980-0CS00
● of communication module PROFIBUS usable 3RW5980-0CP00
● of communication module Modbus TCP usable 3RW5980-0CT00
● of communication module Modbus RTU usable 3RW5980-0CR00
● of communication module Ethernet/IP 3RW5980-0CE00
● of circuit breaker usable at 400 V 3RV2032-4WA10; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V 3RV2032-4WA10; Type of coordination 1, Iq = 10 kA, CLASS 10
● of circuit breaker usable at 400 V at inside-delta
circuit
3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V at inside-delta
circuit
3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10
3RW5217-1AC15 Subject to change without notice
Page 1/
11
09/19/2019 Β© Copyright Siemens
● of the gG fuse usable up to 690 V 3NA3824-6; Type of coordination 1, Iq = 65 kA
● of the gG fuse usable at inside-delta circuit up
to 500 V
3NA3824-6; Type of coordination 1, Iq = 65 kA
● of full range R fuse link for semiconductor
protection usable up to 690 V
3NE1820-0; Type of coordination 2, Iq = 65 kA
● of back-up R fuse link for semiconductor
protection usable up to 690 V
3NE8024-1; Type of coordination 2, Iq = 65 kA
General technical data
Starting voltage [%]
Starting voltage [%]
Starting voltage [%]
Starting voltage [%]Starting voltage [%] 30ξ™’...ξ™’100ξ™’%
Stopping voltage [%]
Stopping voltage [%]
Stopping voltage [%]
Stopping voltage [%]Stopping voltage [%] 50ξ™’...ξ™’50ξ™’%
Start-up ramp time of soft starter
Start-up ramp time of soft starter
Start-up ramp time of soft starter
Start-up ramp time of soft starterStart-up ramp time of soft starter 0ξ™’...ξ™’20ξ™’s
Current limiting value [%] adjustable
Current limiting value [%] adjustable
Current limiting value [%] adjustable
Current limiting value [%] adjustableCurrent limiting value [%] adjustable 130ξ™’...ξ™’700ξ™’%
Certificate of suitability
Certificate of suitability
Certificate of suitability
Certificate of suitabilityCertificate of suitability
● CE marking Yes
● UL approval Yes
● CSA-approval Yes
Product component
Product component
Product component
Product componentProduct component
● is supported HMI-Standard Yes
● is supported HMI-High Feature Yes
Product feature integrated bypass contact system
Product feature integrated bypass contact system
Product feature integrated bypass contact system
Product feature integrated bypass contact systemProduct feature integrated bypass contact system Yes
Number of controlled phases
Number of controlled phases
Number of controlled phases
Number of controlled phasesNumber of controlled phases 3
Trip class
Trip class
Trip class
Trip classTrip class CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Insulation voltage
Insulation voltage
Insulation voltage
Insulation voltageInsulation voltage
● rated value 600ξ™’V
Degree of pollution
Degree of pollution
Degree of pollution
Degree of pollutionDegree of pollution 3, acc. to IEC 60947-4-2
Impulse voltage rated value
Impulse voltage rated value
Impulse voltage rated value
Impulse voltage rated valueImpulse voltage rated value 6ξ™’kV
Blocking voltage of the thyristor maximum
Blocking voltage of the thyristor maximum
Blocking voltage of the thyristor maximum
Blocking voltage of the thyristor maximumBlocking voltage of the thyristor maximum 1ξ™’600ξ™’V
Service factor
Service factor
Service factor
Service factorService factor 1
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated valueSurge voltage resistance rated value 6ξ™’kV
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolation
maximum permissible voltage for safe isolationmaximum permissible voltage for safe isolation
● between main and auxiliary circuit 600ξ™’V
Protection class IP
Protection class IP
Protection class IP
Protection class IPProtection class IP IP00
Usage category acc. to IEC 60947-4-2
Usage category acc. to IEC 60947-4-2
Usage category acc. to IEC 60947-4-2
Usage category acc. to IEC 60947-4-2Usage category acc. to IEC 60947-4-2 AC 53a
Shock resistance
Shock resistance
Shock resistance
Shock resistanceShock resistance 15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
Vibration resistance
Vibration resistance
Vibration resistance
Vibration resistanceVibration resistance 15 mm to 6 Hz; 2g to 500 Hz
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2
Reference code acc. to DIN EN 81346-2Reference code acc. to DIN EN 81346-2 Q
Product function
Product function
Product function
Product functionProduct function
● ramp-up (soft starting) Yes
● ramp-down (soft stop) Yes
● Soft Torque Yes
● Adjustable current limitation Yes
● pump ramp down Yes
3RW5217-1AC15 Subject to change without notice
Page 2/
11
09/19/2019 Β© Copyright Siemens
● Intrinsic device protection Yes
● motor overload protection Yes; Electronic motor overload protection
● Evaluation of thermistor motor protection No
● Inside-delta circuit Yes
● Auto-reset Yes
● Manual RESET Yes
● remote reset Yes; By turning off the control supply voltage
● communication function Yes
● Operating measured value display Yes
● error logbook Yes
● via software parameterizable No
● via software configurable Yes
● PROFIenergy Yes; in connection with the PROFINET Standard communication
module
● firmware update Yes
● removable terminal for control circuit Yes
● torque control No
● analog output Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High
Feature HMI)
Power Electronics
Operating current
Operating current
Operating current
Operating currentOperating current
● at 40 Β°C rated value 38ξ™’A
● at 50 Β°C rated value 33.5ξ™’A
● at 60 Β°C rated value 30.5ξ™’A
Operating current at inside-delta circuit
Operating current at inside-delta circuit
Operating current at inside-delta circuit
Operating current at inside-delta circuitOperating current at inside-delta circuit
● at 40 Β°C rated value 65.8ξ™’A
● at 50 Β°C rated value 58ξ™’A
● at 60 Β°C rated value 52.8ξ™’A
Operating voltage
Operating voltage
Operating voltage
Operating voltageOperating voltage
● rated value 200ξ™’...ξ™’600ξ™’V
● at inside-delta circuit rated value 200ξ™’...ξ™’600ξ™’V
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltageRelative negative tolerance of the operating voltage -15ξ™’%
Relative positive tolerance of the operating voltage
Relative positive tolerance of the operating voltage
Relative positive tolerance of the operating voltage
Relative positive tolerance of the operating voltageRelative positive tolerance of the operating voltage 10ξ™’%
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltage
Relative negative tolerance of the operating voltageRelative negative tolerance of the operating voltage
at inside-delta circuit
at inside-delta circuit
at inside-delta circuit
at inside-delta circuitat inside-delta circuit
-15ξ™’%
Relative positive tolerance of the operating voltage at
Relative positive tolerance of the operating voltage at
Relative positive tolerance of the operating voltage at
Relative positive tolerance of the operating voltage atRelative positive tolerance of the operating voltage at
inside-delta circuit
inside-delta circuit
inside-delta circuit
inside-delta circuitinside-delta circuit
10ξ™’%
Operating power for three-phase motors
Operating power for three-phase motors
Operating power for three-phase motors
Operating power for three-phase motorsOperating power for three-phase motors
● at 230 V at 40 Β°C rated value 11ξ™’kW
● at 230 V at inside-delta circuit at 40 Β°C rated
value
18.5ξ™’kW
● at 400 V at 40 Β°C rated value 18.5ξ™’kW
3RW5217-1AC15 Subject to change without notice
Page 3/
11
09/19/2019 Β© Copyright Siemens


Product specificaties

Merk: Siemens
Categorie: Niet gecategoriseerd
Model: 3RW5217-1AC15

Heb je hulp nodig?

Als je hulp nodig hebt met Siemens 3RW5217-1AC15 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Siemens

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd