General technical data
Size of overload relay
Size of overload relay
Size of overload relay
Size of overload relaySize of overload relay S00
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specific
Size of contactor can be combined company-specificSize of contactor can be combined company-specific S00
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typical
Power loss [W] total typicalPower loss [W] total typical 6.6W
Insulation voltage with degree of pollution 3 rated
Insulation voltage with degree of pollution 3 rated
Insulation voltage with degree of pollution 3 rated
Insulation voltage with degree of pollution 3 ratedInsulation voltage with degree of pollution 3 rated
value
value
value
valuevalue
690V
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated value
Surge voltage resistance rated valueSurge voltage resistance rated value 6kV
Protection class IP
Protection class IP
Protection class IP
Protection class IPProtection class IP
● on the front IP20
Shock resistance
Shock resistance
Shock resistance
Shock resistanceShock resistance 8g / 10 ms
Type of protection
Type of protection
Type of protection
Type of protectionType of protection DMT 98 ATEX G 001
Protection against electrical shock
Protection against electrical shock
Protection against electrical shock
Protection against electrical shockProtection against electrical shock finger-safe
Equipment marking acc. to DIN EN 81346-2 F
Ambient conditions
3RU1116-1AB0 Subject to change without notice
Page 1/
5
12/22/2016 © Copyright Siemens AG
Show actual product details
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea level
Installation altitude at height above sea levelInstallation altitude at height above sea level
maximum
maximum
maximum
maximummaximum
2000m
Ambient temperature
Ambient temperature
Ambient temperature
Ambient temperatureAmbient temperature
● during operation -20...+70°C
● during storage -55...+80°C
● during transport -55...+80°C
Relative humidity during operation
Relative humidity during operation
Relative humidity during operation
Relative humidity during operationRelative humidity during operation 100%
Main circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuit
Number of poles for main current circuitNumber of poles for main current circuit 3
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-
Adjustable pick-up value current of the current-Adjustable pick-up value current of the current-
dependent overload release
dependent overload release
dependent overload release
dependent overload releasedependent overload release
1.1...1.6A
Operating voltage
Operating voltage
Operating voltage
Operating voltageOperating voltage
● at AC-3 rated value maximum 690V
Auxiliary circuit
Number of NC contacts
Number of NC contacts
Number of NC contacts
Number of NC contactsNumber of NC contacts
● for auxiliary contacts 1
Number of NO contacts
Number of NO contacts
Number of NO contacts
Number of NO contactsNumber of NO contacts
● for auxiliary contacts 1
Number of CO contacts
Number of CO contacts
Number of CO contacts
Number of CO contactsNumber of CO contacts
● for auxiliary contacts 0
Operating current of auxiliary contacts at AC-15
Operating current of auxiliary contacts at AC-15
Operating current of auxiliary contacts at AC-15
Operating current of auxiliary contacts at AC-15Operating current of auxiliary contacts at AC-15
● at 24 V 3A
● at 110 V 3A
● at 120 V 3A
● at 125 V 3A
● at 230 V 2A
● at 400 V 1A
Operating current of auxiliary contacts at DC-13
Operating current of auxiliary contacts at DC-13
Operating current of auxiliary contacts at DC-13
Operating current of auxiliary contacts at DC-13Operating current of auxiliary contacts at DC-13
● at 24 V 1A
● at 110 V 0.22A
● at 125 V 0.22A
● at 220 V 0.11A
Protective and monitoring functions
Trip class
Trip class
Trip class
Trip classTrip class CLASS 10
Short-circuit protection
Design of the fuse link
Design of the fuse link
Design of the fuse link
Design of the fuse linkDesign of the fuse link
● for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
Installation/ mounting/ dimensions
Mounting position
Mounting position
Mounting position
Mounting positionMounting position with vertical mounting surface +/-135° rotatable, with vertical
mounting surface +/- 45° tiltable to the front and back
3RU1116-1AB0 Subject to change without notice
Page 2/
5
12/22/2016 © Copyright Siemens AG
Mounting type
Mounting type
Mounting type
Mounting typeMounting type direct mounting
Height
Height
Height
HeightHeight 87mm
Width
Width
Width
WidthWidth 45mm
Depth
Depth
Depth
DepthDepth 78mm
Required spacing
Required spacing
Required spacing
Required spacingRequired spacing
● with side-by-side mounting
— forwards 0mm
— Backwards 0mm
— upwards 0mm
— downwards 0mm
— at the side 0mm
● for grounded parts
— forwards 0mm
— Backwards 0mm
— upwards 0mm
— at the side 6mm
— downwards 0mm
● for live parts
— forwards 0mm
— Backwards 0mm
— upwards 0mm
— downwards 0mm
— at the side 6mm
Connections/Terminals
Product function
Product function
Product function
Product functionProduct function
● removable terminal for auxiliary and control
circuit
No
Type of electrical connection
Type of electrical connection
Type of electrical connection
Type of electrical connectionType of electrical connection
● for main current circuit screw-type terminals
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
Type of connectable conductor cross-sections
Type of connectable conductor cross-sections
Type of connectable conductor cross-sectionsType of connectable conductor cross-sections
● for main contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² max.
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for main contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
Type of connectable conductor cross-sections
Type of connectable conductor cross-sections
Type of connectable conductor cross-sections
Type of connectable conductor cross-sectionsType of connectable conductor cross-sections
● for auxiliary contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14)
Certificates/approvals
3RU1116-1AB0 Subject to change without notice
Page 3/
5
12/22/2016 © Copyright Siemens AG


Product specificaties

Merk: Siemens
Categorie: Niet gecategoriseerd
Model: 3RU1116-1AB0

Heb je hulp nodig?

Als je hulp nodig hebt met Siemens 3RU1116-1AB0 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Siemens

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd