Pagina 1/12
REV 15.08.07
WARNING
OPERATION AND MAINTENANCE MANUAL
MANUAL DE OPERACION Y DE MANTENIMIENTO
MANUEL D’INSTRUCTIONS ET D’ENTRETIEN
Read this manual before you use this Powernailer®. Follow all safety warnings and
instructions. If you are uncertain about the operation of the nailer, call us directly
at 1-800-323-1653 for assistance or contact the closest Powernail Dealer for help.
Please retain this information for future reference.
2
The BR50 Brad Nailer is a trigger-pull nailer designed to bring Powernail quality
and fl ooring expertise to a pneumatic brad nailer.
The BR50 is designed for use with brad fi nish nails in lengths of 5/8” to 2”.
The Model BR50 nails from 1/2” to 1-3/4” board and trim.
INTRODUCTION
INDEX
LIMITED WARRANTY
POWERNAIL® Company, Inc. warrants to its customer, and to the fi rst end-use purchaser
of POWERNAIL BR50 Brad Nailer purchased from an authorized POWERNAIL
distributor, that each serialized manufactured BR50 Brad Nailer by POWERNAIL®, for
a period of 12 months from the date of purchase; shall be free of defects in materials and
workmanship and will meet POWERNAIL’S specifi cations in effect at the time of product
shipment. POWERNAIL will repair or replace, at its option, any BR50 Brad Nailer that
does not conform to this warranty. Claims must be made no later than fi fteen (15) days after
the end of the warranty period. POWERNAIL will perform all repair or replacements itself
or through its authorized contractors. POWERNAIL is not responsible for shipping, labor
or other direct or indirect costs. Damage caused by abuse, misuse, unusual or excessive
wear is excluded. Repair or modifi cation of the Products by unauthorized parties will
void this warranty. The customer is responsible for returning Products to POWERNAIL
for verifi cation of nonconformance. Warranties for Products not manufactured by
POWERNAIL are limited to warranties provided to POWERNAIL by the manufacturer of
such product that are assignable to customer.
THESE WARRANTIES AND REMEDIES ARE EXCLUSIVE OF ALL OTHERS,
EXPRESS OR IMPLIED. THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR PURPOSE ARE EXPRESSLY EXCLUDED. IN NO EVENT SHALL
POWERNAIL’S LIABILITY FOR A WARRANTY CLAIM EXCEED THE PRICE PAID
TO POWERNAIL FOR THE NONCONFORMING PRODUCT, REGARDLESS OF THE
FORM OR BASIS OF THE CLAIM OR CAUSE OF ACTION.
Index..................................... 2
Warranty............................... 2
Safety Instructions................ 3
Operating the tool................. 4-6
Air Supply............................. 5
Loading fasteners................. 6
Clearing a jam...................... 7
Safety Labels........................ 7
Troubleshooting Chart.......... 9
Parts List........................ 10
Schematic........................ 11
Phone Support..................... 12
Web Site.............................. 12
Powernail Company Info..... 12
SAFETY INSTRUCTIONS
3
When operating this Nailer, the operator and others in the work area should ALWAYS wear approved
SAFETY GLASSES, with front and side eye protection. Eye protection will help guard against fl ying
nails and debris, which could cause severe eye injury.
EAR PROTECTION should be used to prevent hearing damage when there are high noise levels
in the work area. ALWAYS use ear plugs with a noise reduction rated at 29 db or higher at a
construction site.
Noise characteristic values in accordance with ENxx1:
A-weighted single-event sound pressure level at operator’s position: LPA, ls94dBA
A-weighted single sound pressure level:LpA,ls,lm89dBA
Vibration characteristic values in accordance with ISO 8662, PART II
Weighted root mean square acceleration 3.2m/s²
Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or when
the Nailer is not in use. Do not use on scaffolding or ladders and disconnect nailer from air supply when
transporting
between installation areas.
Never attach the female end of a quick disconnect to the Nailer. This will trap air inside the Nailer and permit it
to be discharged. Only the unrestricted male connection should be attached to the Nailer.
Nailer requires an air source that can continuously deliver 70 to 100 psi at 3-1/2 cubic feet of air per minute
for operation.
Normal air pressure should not exceed 100 psi or damage to the Nailer and seals may occur. Excess air
pressure can cause the Nailer to explode.
To prevent fi re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no
oxygen or combustible gasses) to power this Nailer.
Nailer is intended for use installing wood fl ooring and is not to be used for purposes not specifi ed in the
operations manual.
Do not use any nails other than 18 gauge straight brad fi nish nails which are designed specifi cally for your
nailer.
Use only Powernail replacement parts in the repair or maintenance of this nailer. Parts or repair services are
available from the manufacturer or from agents authorized by the manufacturer. Repairs should be carried out
only by trained service personel in the fi eld of fastener driving tools who will observe proper safety controls
while performing maintenance. Service personel should be qualifi ed to assess the safe working condition of
fastener driving tools.
Always make sure nailer is empty of nails before connecting an air hose, so as to prevent any accidental
discharge from occurring. ONLY CONNECT AIR TO AN UNLOADED NAILER.
Do not depress the trigger when loading. If the fasteners are jammed, disconnect the tool from the air supply
before you remove the jammed nails.
Never place any part of the body in the discharge path of the Nailer when air is connected to the
Nailer. Never point the tool at yourself or others, even if the tool is not loaded. For safety, keep out
of reach of children. Never leave the Nailer unattended while it is connected to an air supply.
Do not fi re into hard materials or attempt to use on hard or brittle material such as concrete, steel
or tile. Before using this tool, carefully check that all parts are working correctly. Do not use the tool if it is not
operating correctly, check for causes and adjust as necessary for proper operation. When not in use, the tool
should be cleaned, fully assembled and then stored in a dry location. This will extend the life of the tool and
reduce any oxidation.
Product specificaties
Merk: | POWERNAIL |
Categorie: | Compressor |
Model: | BR50 |
Heb je hulp nodig?
Als je hulp nodig hebt met POWERNAIL BR50 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Compressor POWERNAIL
10 Juni 2023
5 Juni 2023
28 Mei 2023
26 Mei 2023
26 Mei 2023
21 Mei 2023
12 Mei 2023
Handleiding Compressor
- Compressor Bosch
- Compressor Xiaomi
- Compressor AEG
- Compressor DeWalt
- Compressor Airpress
- Compressor Bavaria
- Compressor Boss
- Compressor Danfoss
- Compressor Duro
- Compressor Duro Pro
- Compressor Einhell
- Compressor Emax
- Compressor Eufab
- Compressor Ferm
- Compressor Festool
- Compressor Global
- Compressor Gude
- Compressor Hikoki
- Compressor Hitachi
- Compressor Holzmann
- Compressor Hyundai
- Compressor Kibani
- Compressor Laica
- Compressor Livoo
- Compressor Makita
- Compressor Merlin
- Compressor Metabo
- Compressor Milwaukee
- Compressor Nilfisk
- Compressor Parkside
- Compressor Powerplus
- Compressor Robust
- Compressor Samson
- Compressor Scheppach
- Compressor Silvercrest
- Compressor Silverline
- Compressor Stanley
- Compressor Technaxx
- Compressor Toolcraft
- Compressor Topcraft
- Compressor Trotec
- Compressor Ultimate Speed
- Compressor Vonroc
- Compressor Westfalia
- Compressor WilTec
- Compressor Workzone
- Compressor Zipper
- Compressor OKAY
- Compressor Omnitronic
- Compressor Osram
- Compressor Ozito
- Compressor Black And Decker
- Compressor Steren
- Compressor Cocraft
- Compressor Draper
- Compressor Meec Tools
- Compressor Senco
- Compressor Hamron
- Compressor Aerotec
- Compressor Contimac
- Compressor HBM
- Compressor Power Craft
- Compressor Tacklife
- Compressor Truper
- Compressor Fieldmann
- Compressor Biltema
- Compressor Porter-Cable
- Compressor Sun Joe
- Compressor Dedra
- Compressor CMI
- Compressor Herkules
- Compressor Bimar
- Compressor MSW
- Compressor Sthor
- Compressor Craftsman
- Compressor Alphacool
- Compressor Freeman
- Compressor Pretul
- Compressor Hazet
- Compressor Full Boar
- Compressor Yato
- Compressor Avantco
- Compressor Auto Joe
- Compressor Unimac
- Compressor PreSonus
- Compressor Carel
- Compressor Outbac
- Compressor Golden Age Project
- Compressor Eventide
- Compressor Abac
- Compressor DBX
- Compressor SPL
- Compressor Lindell Audio
- Compressor Arebos
- Compressor Anova
- Compressor Pansam
- Compressor Narvon
- Compressor Airman
- Compressor Pro-Lift
- Compressor Aomni
- Compressor Numax
- Compressor TOOLMATE
- Compressor California Air Tools
- Compressor Ilsco
- Compressor Hulk Power
- Compressor Cartrend
- Compressor Prowork
- Compressor Proviel
- Compressor Creemers
- Compressor ExelAir
- Compressor TJM
- Compressor TAURUS Titanium
Nieuwste handleidingen voor Compressor
14 November 2024
20 Oktober 2024
15 Oktober 2024
15 Oktober 2024
6 September 2024
6 September 2024
5 September 2024
5 September 2024
29 Augustus 2024
27 Augustus 2024