POWERNAIL 50F Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor POWERNAIL 50F (12 pagina's) in de categorie Compressor. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
REV 20.04.02
WARNING
OPERATION AND MAINTENANCE MANUAL
MANUAL DE OPERACION Y DE MANTENIMIENTO
MANUEL D’INSTRUCTIONS ET D’ENTRETIEN
Read this manual before you use this Powernailer®. Follow all safety warnings and
instructions. If you are uncertain about the operation of the nailer, call us directly
at 1-800-323-1653 for assistance or contact the closest Powernail Dealer for help.
Please retain this information for future reference.
2
The Model 50F trigger-pull nailer is designed to bring Powernail quality and ooring expertise
to a pneumatic nailer. The Model 50F is designed for use with 1-1/4” to 1-3/4”, 18 gauge
L-Cleat Powernails®. The Model 50F nails from 3/8” to 3/4 ooring through the use of a
FLEX adjustable foot assembly that can be adjusted to t di erent ooring pro les.
INTRODUCTION
INDEX
LIMITED WARRANTY
POWERNAIL® Company, Inc. warrants to its customer, and to the rst end-
use purchaser of POWERNAIL Model 50F POWERNAILER purchased from
an authorized POWERNAIL distributor, that each serialized manufactured
Model 50F POWERNAILER by POWERNAIL®, for a period of 12 months
from the date of purchase; shall be free of defects in materials and workmanship
and will meet POWERNAIL’S speci cations in e ect at the time of product
shipment. POWERNAIL will repair or replace, at its option, any Model 50F
POWERNAILER that does not conform to this warranty. Claims must be made
no later than fteen (15) days after the end of the warranty period. POWERNAIL
will perform all repair or replacements itself or through its authorized distributors.
POWERNAIL is not responsible for shipping, labor or other direct or indirect
costs. Damage caused by abuse, misuse, unusual or excessive wear is excluded.
Repair or modi cation of the Products by unauthorized parties will void this
warranty. The customer is responsible for returning Products to POWERNAIL
for veri cation of nonconformance. Warranties for Products not manufactured
by POWERNAIL are limited to warranties provided to POWERNAIL by the
manufacturer of such product that are assignable to customer.
THESE WARRANTIES AND REMEDIES ARE EXCLUSIVE OF ALL OTHERS,
EXPRESS OR IMPLIED. THE WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR PURPOSE ARE EXPRESSLY EXCLUDED. IN NO
EVENT SHALL POWERNAIL’S LIABILITY FOR A WARRANTY CLAIM
EXCEED THE PRICE PAID TO POWERNAIL FOR THE NONCONFORMING
PRODUCT, REGARDLESS OF THE FORM OR BASIS OF THE CLAIM OR
CAUSE OF ACTION.
Index............................ 2
Warranty........................ 2
Operating the tool.......... 4-6
FLEX Foot Adjustment...5
Air Supply...................... 6
Maintenance.................. 7
Safety Labels................. 7
Loading Fasteners.........6
Clearing a jam............... 8
Troubleshooting Chart... 9
Schematic / Parts List.. 10-11
Nail Depth Chart............ 12
Phone Support............. 12
Web Site........................ 12
Powernail Company Info 12
Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or
when the Nailer is not in use. Do not use on sca olding or ladders and disconnect nailer from air supply
when transporting between installation areas.
Never attach the female end of a quick disconnect to the Nailer. This will trap air inside the Nailer and
permit it to be discharged. Only the unrestricted male connection should be attached to the Nailer.
Nailer requires an air source that can continuously deliver 70 to 120 psi at 3-1/2 cubic feet of air per
minute for operation. Normal air pressure should not exceed 120 psi or damage to the Nailer and seals
may occur. Excess air pressure can cause the Nailer to explode. Do not continue to use a tool that leaks
air or does not function properly. Notify your nearest Powernail representative if your tool continues to
experience functional problems.
To prevent re or explosion, use only regulated compressed air—do not use bottled gases of any
kind (no oxygen or combustible gasses) to power this Nailer. Nailer is intended for use installing wood
ooring and is not to be used for purposes not speci ed in the operations manual.
Do not use any nails other than Powernail® Powercleats which are 18 gauge L-cleat nails speci cally
designed for use in any 18 gauge Powernailer. Powercleat nails are available in lengths of 1-1/4”, 1-1/2
and 1-3/4”. Contact your Powernail Dealer for the correct Powercleats for the Model 50F.
Use only Powernail replacement parts in the repair or maintenance of this nailer. Parts or repair services
are available from the manufacturer or from agents authorized by the manufacturer. Repairs should be
carried out only by trained service personel in the eld of fastener driving tools who will observe proper
safety controls while performing maintenance. Service personel should be quali ed to assess the safe
working condition of fastener driving tools.
Always make sure Nailer is empty of nails before connecting air hose, so as to prevent any accidental
discharge from occurring. ONLY CONNECT AIR TO AN UNLOADED NAILER.
Do not depress the trigger when loading. If the fasteners are jammed, disconnect the tool from the air
supply before you remove the jammed nails.
Never place any part of the body in the discharge path of the Nailer when air is connected to
the Nailer. Never point the tool at yourself or others, even if the tool is not loaded. For safety,
keep out of reach of children. Never leave the Nailer unattended while it is connected to an
air supply. Never disable, clamp or tape the safety trigger in an activated position.
Do not re into hard materials or attempt to use on hard or brittle material such as concrete, steel or tile.
Before using this tool, carefully check that all parts are working correctly. Do not use the tool if it is not
operating correctly, check for causes and adjust as necessary for proper operation. When not in use, the
tool should be cleaned, fully assembled and then stored in a dry location. This will extend the life of the
tool and reduce any oxidation.
When operating this Nailer, the operator and others in the work area should ALWAYS
wear approved SAFETY GLASSES, with front and side eye protection. Eye protection
will help guard against ying nails and debris, which could cause severe eye injury.
EAR PROTECTION should be used to prevent hearing damage when there are high
noise levels in the work area. ALWAYS use ear plugs with a noise reduction rated at 29
db or higher at a construction site.
Do not operate this tool if it does not contain a legible WARNING LABEL.
SAFETY INSTRUCTIONS
3
Noise characteristic values in accordance with ENxx1:
A-weighted single-event sound pressure level at operator’s position: LPA, ls94dBA
A-weighted single sound pressure level:LpA,ls,lm89dBA
Vibration characteristic values in accordance with ISO 8662, PART II
Weighted root mean square acceleration 3.2m/s²


Product specificaties

Merk: POWERNAIL
Categorie: Compressor
Model: 50F

Heb je hulp nodig?

Als je hulp nodig hebt met POWERNAIL 50F stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Compressor POWERNAIL

Handleiding Compressor

Nieuwste handleidingen voor Compressor