POWERNAIL 50P FLEX Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor POWERNAIL 50P FLEX (16 pagina's) in de categorie Compressor. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
OPERATION AND MAINTENANCE MANUAL
MANUAL DE OPERACION Y DE MANTENIMIENTO
MANUEL D’INSTRUCTIONS ET D’ENTRETIEN
Read this manual before you use this Powernailer®. Follow all safety warnings and
instructions. If you are uncertain about the operation of the nailer, call us directly
at 1-800-323-1653 for assistance or contact the closest Powernail Dealer for help.
Please retain this information for future reference.
WARNING
rev. 2020.03.03
REV 3 (TL)
The Powernail FLEX Power Roller Pneumatic Nailer is
designed to bring Powernail quality to a pneumatic nailer.
For those looking for the ease of use of a pneumatic
tool, the Powernail FLEX Power Roller is designed for
use with only 1" , 1-1/4", 1-1/2" and 1-3/4" (18 gauge)
Powercleats® nails.
The Powernail FLEX Power Roller is recommended for
use on thinner 3/8", 1/2", 5/8" and 3/4" solid tongue and
groove hardwood as well as some other hard exotics,
bamboo, and engineered woods.
For a superior pneumatic Nailer, look to the
company that has been the industry’s quality leader,
POWERNAIL® COMPANY, INC.
INTRODUCTION
INDEX
LIMITED WARRANTY
POWERNAIL® Company, Inc. warrants to its customer, and to the rst end-use purchaser of POWERNAIL
ooring nailers purchased from an authorized POWERNAIL distributor, that each serialized manufactured nailer
by POWERNAIL®, for a period of 12 months from the date of purchase, and with respect to the nailer body
(speci cally Models 200, 445, and 50P), for a period of 10 years from date of purchase, (“warranty period”); shall
be free of defects in materials and workmanship and will meet POWERNAILs speci cations in effect at the time of
Product shipment. POWERNAIL will repair or replace, at its option, any Powernailer® that does not conform to this
warranty. Claims must be made no later than fteen (15) days after the end of the warranty period. POWERNAIL
will perform all repair or replacements itself or through its authorized contractors. POWERNAIL is not responsible
for shipping, labor or other direct or indirect costs. Damage caused by abuse, misuse, unusual or excessive wear is
excluded. Repair or modi cation of the Products by unauthorized parties will void this warranty. The customer is
responsible for returning Products to POWERNAIL for veri cation of nonconformance. Warranties for Products
not manufactured by POWERNAIL are limited to warranties provided to POWERNAIL by the manufacturer of
such product that are assignable to customer.
THESE WARRANTIES AND REMEDIES ARE EXCLUSIVE OF ALL OTHERS, EXPRESS OR IMPLIED. THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE ARE EXPRESSLY EXCLUDED.
IN NO EVENT SHALL POWERNAILS LIABILITY FOR A WARRANTY CLAIM EXCEED THE PRICE PAID
TO POWERNAIL FOR THE NONCONFORMING PRODUCT, REGARDLESS OF THE FORM OR BASIS OF
THE CLAIM OR CAUSE OF ACTION.
Index..................................... 2
Warranty............................... 2
Safety Instructions................ 3
Powernail Company Info...... 3
Operating Instructions.......... 4-8
Parts & Service.................... 5-8
Drive Blade........................... 6
Seal Replacement................. 6-7
Safety Labels........................ 8
Parts List.............................. 9-11
Seal Locations Diagram....... 12
Schematic ........................... 13
Depth Chart.......................... 14
Troubleshooting Chart......... 15
POWERNAIL COMPANY, INC.
1300 Rose Road, Lake Zurich, IL 60047 US
Phone: 1-800-323-1653 OR 847-847-3000
www.powernail.com
SAFETY INSTRUCTIONS
Always use approved and when operating this Nailer. The SAFETY GLASSES EAR PROTECTION
operator and others in the work area should always wear approved and eye protection FRONT SIDE
when operating this Nailer. Eye protection will help guard against ying nails and debris, which could
cause severe eye injury.
EYE AND EAR PROTECTION should be used to prevent hearing damage when there are high noise
levels in the work area.
ALWAYS use ear plugs with a noise reduction rated at 29 db or highter at a construction site.
Nailer noise ratings are at LPA-1sd=90.6,
LWA-1sd=99.3 and LPA-1s,1m=86.3.
Nailer vibration rating: m/s2=3.05.
Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or when the
Nailer is not in use. Do not use on scaffolding or ladders and disconnect nailer from air supply when transporting
between installation areas.
Never attach the female end of a quick disconnect to the Nailer. This will trap air inside the Nailer and permit it to
be discharged. Only the unrestricted male connection should be attached to the Nailer.
Nailer requires an air source that can continuously deliver 80 to 110 psi at 3-1/2 cubic feet of air per minute for
operation.
Normal air pressure should not exceed 120 psi or damage to the Nailer and seals may occur. Excess air pressure
can cause the Nailer to explode.
To prevent re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no oxygen
or combustible gasses) to power this Nailer.
Nailer is intended for use installing wood ooring and is not to be used for purposes not speci ed in the operations
manual.
Do not use any nails other than Powernail Powercleats Nails which are speci cally designed for use in any
Powernailer. Powercleats Nails are available in various lengths. Contact your Powernail Dealer for Powercleats
Nails.
Use only Powernail replacement parts in the repair or maintenance of this nailer. Parts or repair services are
available from the manufacturer or from agents authorised by the manufacturer. Repairs should be carried out
only by trained service personel in the eld of fastener driving tools who will observe proper safety controls while
performing maintenace. Service personel should be quali ed to to asses the safe working condition of fastener
driving tools.
Never place any part of the body in the discharge path of the Nailer when air is connected to the Nailer. Always
make sure Nailer is empty of cleats before connecting air hose so as to prevent any accidental discharge from
occurring.
Never leave the Nailer unattended while it is connected to an air supply.
Whenever air is connected to the Nailer, keep body parts away from the nail discharge path. Disconnect
the air line before making adjustments or repairs on the Nailer. Only connect air to an unloaded Nailer
so as to prevent accidental discharge.
Nailer is activated by striking the plunger. Do not work on scaffolding,
ladders, elevated or uneven surfaces where the nailer could fall and self-
activate. Do not leave air attached to the Nailer when moving from one
install location to another.


Product specificaties

Merk: POWERNAIL
Categorie: Compressor
Model: 50P FLEX

Heb je hulp nodig?

Als je hulp nodig hebt met POWERNAIL 50P FLEX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Compressor POWERNAIL

Handleiding Compressor

Nieuwste handleidingen voor Compressor