Angelcare ACAM2 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Angelcare ACAM2 (49 pagina's) in de categorie Babyfoon. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/49
Keep user’s guide for future reference. Please read the warnings and
safety instructions carefully before assembling & using the product.
Failure to follow the warnings and the instructions could result in serious
injury or death or damage to the product.
Model ACAM1
Additional Nursery Unit
Compatible with models
AC527, AC337, AC327 & AC320
WARNING
Model ACAM2
Additional Nursery Unit
& Movement Sensor Pad
Compatible with models
AC527, AC337, AC327 & AC320
OWNER’S MANUAL
IMPORTANT - INTENDED USE
is product is NOT intended and should NOT be used to prevent Sudden Infant Death Syndrome (SIDS).
is product is NOT intended to diagnose, treat, mitigate, cure or prevent any disease or condition.
is is a product to monitor the movement of healthy babies and is not a substitute for parental care.
3. DO NOT use a cot mobile and other cot accessories
that may produce movements or vibrations
4. Fans (including ceiling), washing machines, floor
boards, central heating or loud music are all forms
of movement and vibration and may interfere and be
detected by the Sensor Pad
5. e additional Nursery Unit and Sensor Pad must
be positioned 2 metres (6.5 feet) minimum from any
existing Nursery Unit and Sensor Pad as they could
interfere with performance.
6. DO NOT use with bedside cot touching parent’s/
carer’s bed as the Sensor Pad will detect your
movements
7. DO NOT place the cot against a wall or skirting
board as vibrations may be detected
8. Following removal of baby from the cot, some
mattresses may still detect mattress movement
due to it forming back into shape and alarm may not
sound
9. Ensure cot is stable to eliminate any movement
10. Cot should not be placed in reaching distance of
another cot or bed
11. DO NOT use other wireless devices in the same
room as the monitor (including mobile phones,
microwaves...). ey may interfere with signal and
performance
12. e Sensor Pad is made of plastic and does
not permit air to circulate. erefore, mildew build
up could develop underneath the mattress in the
Sensor Pad area
We suggest rotating & airing /drying the mattress
regularly to prevent any mildew. AVOID CONTACT
WITH MOISTURE. Clean - wipe with a dry, lint-free
cloth
13. e Sensor Pad is not suitable for use above
age 24 months
14. is product cannot replace responsible
adult supervision
β€’ is product is designed to aid in the monitoring of
your child. When using the monitor, you must still
WARNING
- MOVEMENT SENSOR PAD - NO ALARM
β€’ Sources of vibration & movement, other than your baby’s, can be detected by
the Sensor Pad and interfere with the performance of your Angelcare monitor
β€’ e alarm will not sound if it detects movement other than your baby’s
β€’ High sensitivity settings can pick up other sources of vibration & movement -
please read instructions on sensitivity setting to adjust accordingly
β€’ Other active and older babies (toddlers) in the same room can be detected and
the alarm will not sound
β€’ Ensure the baby’s environment is FREE from any movements or vibrations when
using the Sensor Pad - see below warnings 3 to 11
2
is baby monitor is compliant with all relevant standards regarding electromagnetic fields and is, when
handled as described in the User’s Guide, safe to use
WARNINGS
1. Because of the serious strangulation risk to infant & toddlers, parents & caregivers should note
the following Warnings
2.
WARNING
- Strangulation Hazard –
Children have STRANGLED in cords
β€’ KEEP OUT the Nursery Unit and adaptor cords of the
reach of children more than 3 feet or 1 metre away
β€’ NEVER ONLY use extension cords with adaptors. use
adaptors provided
β€’ is product is NOT a Toy. NEVER allow children to
play with it
E
N
provide the supervision necessary for the continued
safety of your child
β€’ Use this appliance ONLY for its intended use as
described in this manual
15. e Sensor Pad is not intended to be used
to determine if a child is out of the cot
16. ALWAYS be sure to immediately check on
baby whenever an alarm sounds
17. Keep cords out of the reach of ANY children
18. ONLY use the chargers and power adaptors
provided. Do not use other types as this
may damage the device and battery pack (if
included in your model)
19. Adult assembly required. Keep small parts
away from children when assembling
20. Follow instructions and test this monitor
and its functions so you are familiar with it
prior to actual use. ALWAYS be sure that both the
transmitter and receiver are working properly and
are within range of each other – check periodically
and when changing location of the Nursery Unit
21. DO NOT touch the plug contacts especially
with sharp or metal objects
22. DO NOT use the baby monitor near water.
Care should be taken so that objects DO NOT fall
onto units and that liquids are not spilled into either
unit or Sensor Pad through its openings
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
23. Keep monitor AWAY from heat sources
(such as stoves, radiators, etc.). Heat can
damage the case or electrical parts
24. ALWAYS place both the Nursery Unit and the
Parent Unit on a flat solid surface in an upright
position that allows for proper VENTILATION. DO
NOT place on sofas, cushions, beds, etc. which may
block ventilation or anywhere that would muffle the
sound or interfere with the normal flow of air
25. e baby monitor can only be used between
10Β°C and 40Β°C (50Β°F and 104Β°F)
WARNINGS AND SAFETY
INSTRUCTIONS  BATTERY SPECIFIC
26. ALWAYS keep all batteries away from children
27. e Parent Unit battery is a replaceable
Li-Ion battery. e Wireless Sensor Pad uses a
replaceable Button Cell Lithium Battery. Only
use the Angelcare recommended replacement
battery (see Technical Specification)
β€’ Danger of explosion if the wrong battery is used
or if replaced incorrectly. Refer to User’s Guide for
correct battery installation
β€’ DO NOT short circuit supply terminals
28. DO NOT mix old and new batteries and only
use Angelcare recommended replacement
batteries (see Technical Specification)
29. is product contains a Button Cell Battery
and if swallowed can cause internal chemical
burns in as little as two hours and lead to
death. Dispose of used batteries immediately.
Keep new and used batteries away from
children. If you think batteries might have
been swallowed or placed inside any of the
body, seek medical attention.
30. e Button Cell Battery represents a small
part and a choking hazard – KEEP away from
children!
31. Exercise care in handling batteries in order
not to short out the batteries with conducting
materials such as rings, bracelets and keys
32. Overcharging, short circuiting, reverse
charging, mutilation, or incineration of
batteries must be avoided to prevent one or
more of the following occurrences: release of toxic
materials, release of hydrogen and/or oxygen, gas
and rise in surface temperature
33. DO NOT attempt to recharge batteries
provided with or identified for use with this
product that are not intended to be charged
e batteries may leak corrosive electrolyte or
explode
34. Incorrect polarity installation of the
batteries in the end product must be avoided
Reverse insertion of batteries can cause charging,
and that may result in leakage or explosion
35. Remove batteries from units if you store
the product over 30 days because the batteries
could leak and damage the product
36. Discard β€˜dead’ batteries as soon as possible
since β€˜dead’ batteries are more likely to leak in a
product. If a battery has leaked or vented, discard
product responsibly
37. DO NOT store this product, or the batteries
provided with or identified for use with this
product, in high-temperature & high humidity
environments and avoid direct sunlight
IMPORTANT SAFETY INSTRUCTIONS
38. Sensor Pad –
β€’ If your cot does not have a solid, stationary,
completely flat, firm surface including a spring or
slat base, place a hard board between the cot base
and the Sensor Pad, to ensure correct operation
(see specification on STEP 2)
β€’ e Sensor Pad functions with standard cot sprung
and foam mattresses and not memory foam (partial
or full), hollow frame construction mattresses and
water beds. Please consult Angelcare if unsure of
mattress compatibility
39. is monitor uses public airwaves to transmit
signals. e Parent Unit may pick up signals or
interference from other nursery monitors in your
area. Your monitor may even be picked up by other
households. To protect your privacy, make sure both
units are turned OFF when not in use
40. Power cord protection - Protect the
Adaptor’s power cord from being walked on
or pinched by furniture or other items – Power
3


Product specificaties

Merk: Angelcare
Categorie: Babyfoon
Model: ACAM2

Heb je hulp nodig?

Als je hulp nodig hebt met Angelcare ACAM2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Babyfoon Angelcare

Handleiding Babyfoon

Nieuwste handleidingen voor Babyfoon

Alecto

Alecto DVM- 360 Handleiding

14 November 2024
Alecto

Alecto DVM-700 Handleiding

14 November 2024
Alecto

Alecto DVM-200 Handleiding

14 November 2024
VTech

VTech RM9751 Handleiding

13 December 2024
VTech

VTech RM5754-2HD Handleiding

13 December 2024
VTech

VTech RM5764-2HD Handleiding

13 December 2024
VTech

VTech VC2105 Handleiding

13 December 2024
VTech

VTech RM2751 Handleiding

13 December 2024
VTech

VTech RM5754HD Handleiding

13 December 2024