Swann SW351-KCG Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Swann SW351-KCG (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
Operating Instructions
Magnetic Keypad
Door Alarm
SW351-KCG
Advanced security made easy
2222
IMPORTANT - Read Before Installing
Do not• install the alarm unit near devices which generate magnetic elds (such as
microwaves).
Do not• install any the alarm unit in direct sunlight.
Use only alkaline batteries.•
All components are for indoor use only.• Do not install outdoors.
Replace the batteries in the unit every six months.•
Test the alarm periodically• (every 1 - 2 months and each time you change the
batteries) to ensure it is working properly.
This alarm system is designed to be, and acts as, a theft deterrent. This system, •
like any other, cannot offer complete protection for your home or business - it
is simply an alarm system. Like all practical systems, it has limitations and it could be
disabled by a skilled intruder. We suggest that you avoid relying solely on this magnetic
switch alarm to protect your property, but use it as part of a comprehensive security
solution. You can increase your level of protection through the use of high-quality
locks, stronger doors, guards for your windows and a CCTV system and recording
devices.
About the Alarm Unit
Congratulations on your purchase of this
keypad controlled magnetic alarm from
Swann! This simple but powerful stand-
alone alarm unit can be used to secure
almost any door or window you want.
Selecting Modes
The is located within the battery compartment.Mode Select Switch
Alarm Mode: When the alarm is tripped, a thirty second countdown will begin - the
indicator LED on the front of the alarm unit will flash during this countdown. During this
time, the alarm can be disarmed by entering your passcode. If the passcode is not entered,
the alarm will sound at full volume.
Chime Mode: Each time the alarm is tripped, the alarm unit will chime, much like a doorbell.
The alarm does not need to be armed.
Arming Delay
When you use your passcode to arm the system, it will enter an arming delay of forty-five
seconds. The indicator LED will flash during this time, and the alarm cannot be tripped. This
is intended to give you time to arm the alarm unit and leave the area.
Operating Instructions
Siren
Magnetic Detector
Indicator LED
Keypad
Magnetic
Detector
33
Installation
The alarm unit should be mounted on a door or window frame, and the magnetic trigger
should be mounted on the door or window itself. When the door/window is closed, two
black arrows (the one on the trigger and either one on the alarm unit) should be as close to
touching as practicable.
To mount the alarm unit:
Attach the alarm unit using one of the provided screws - the mounting hole is in the •
upper centre on the rear of the alarm unit.
Using the two smaller screws, attach the magnetic trigger to the door/window. Ensure •
that when the door or window is shut that the two black arrows are as close to
touching as they can be. The alarm will be triggered if the arrows are moved more than
approximately 1/3” (about 8-10mm) apart.
Setting your Passcode
Your passcode must be four digits long, and should be something that you will remember.
Try to avoid obvious combinations (such as 1234 or similar).
To set your passcode:
Open the battery compartment and press the button labeled •
LEARN.
Enter your four digit passcode. When entering the passcode, •
press buttons slowly and deliberately, waiting for the alarm
unit to beep quickly to confirm each button press.
A louder, longer beep will confirm that a new passcode has •
been set.
Replacing Batteries
The batteries in the alarm unit should be replaced every six months. If you’re using the
sensor in chime mode and get a lot of visitors, you may need to change them more often.
Open the battery compartment and remove any batteries already installed.•
Replace with three fresh alkaline AAA batteries. Do not mix battery types. Do not use •
rechargeable batteries.
Low Battery Indicator
When the batteries in the alarm unit are running out, the LED on the front of the alarm unit
will flash slowly (more slowly than during the arming delay). If the LED starts flashing in this
way, change the batteries as soon as possible.
Technical Specifications
General
Power Requirements 3 x Alkaline AAA
Batteries (4.5V DC)
Modes 2 (Alarm and Chime)
Chime Mode
Chime Volume > 90dB
Chime Duration Approx. 2s
Re-Trigger Delay 5s
Alarm Mode
Passcode Protected Yes (4-digit numerical code)
Passcode Learning Duration 15s
Siren Volume > 110dB
Siren Duration 30s
Entry Delay 30s
Exit Delay 45s
Re-Trigger Delay 5s
Inside the Battery Compartment
showing the Mode Switch and
LEARN button.


Product specificaties

Merk: Swann
Categorie: Niet gecategoriseerd
Model: SW351-KCG
Kleur van het product: Wit
Soort: Draadloze sirene
Ondersteund aantal accu's/batterijen: 3
Batterijtechnologie: Alkaline
Type batterij: AAA
Alarm decibels: 110 dB
Alarm duur: 30 s

Heb je hulp nodig?

Als je hulp nodig hebt met Swann SW351-KCG stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Swann

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd