GIRA
Info Smoke detector plus / VdS
Instructions for Installation
Smoke detector plus / VdS 02/02 Seite: 1 von 6
Smoke detector plus / VdS with relay module
pure white Art. Nr.: 0496 06
alu 0496 07
Smoke detector plus / VdS with radio transmitter module
pure white Art. Nr.: 0496 08
alu 0496 09
Product features
• Battery-operated stand-alone Home Smoke Detector working on photoelectric principle.
• Automatic self-test for smoke-sensing electronics, therefore extremely reliable and immune to
interference.
• Option of operating as a wireless network with radio transmitter modules and a wireless alarm unit
(available as extras).
• Loud pulsating warning tone if smoke detected, approx. 85 dB (A).
• Battery low-power monitor (LED and short beeps at intervals) warns that battery voltage is
growing weaker, for up to about 30 days.
• Contamination/fault warning function with LED and short beep.
• Option of operating as a wired network with relay modules (available as extras). Up to 40 smoke
detectors can be linked together. If one smoke detector identifies a fire, the alarm is relayed all the
other smoke detectors in the network.
• Integrated test button: if the smoke detector emits its warning tone when the test button is
pressed, it is in good working order.
• Simple mechanical safeguard prevents smoke detector clicking into place in its base if no battery
is fitted.
• Damage to the detector is not possible if the battery is installed with the wrong polarity.
Operating principle
The smoke detector is an early warning device for smouldering fires as well as flaming fires that
develop smoke. It operates on the proven light scatter principle. lnside the sensing chamber a light
source and a light sensor are arranged so that light normally does not fall on the sensor. It is only
when airborne particles enter the chamber that light is scattered onto the sensor (Tyndall effect) to
produce an electrical signal. This design means that no radioactive source is required. Smouldering
fires in particular are quickly identified by the smoke detector and the alarm given.
If smoke enters the sensing chamber, the built-in sounder is triggered. A logic circuit to eliminate false
alarms delays the alarm signal and resetting by up to 30 seconds.
This product has been approved by the Schadenverhütung GmbH in Cologne (VdS). Only security
products meeting the high quality demands of the prEN 12239 receive this approval.
Important test criteria are:
• reliable smoke detection characteristics
• good smoke entry
• immunity to electrostatically discharge
• functional check and battery presence control
• Test button
GIRA
Info
Smoke detector plus / VdS
Instructions for Installation
Smoke detector plus / VdS 02/02 Seite: 2 von 6
Choice of location
The minimum protection is one smoke detector on every
floor (hall or landing area) and in every child’s bedroom.
It is better, however, to have a smoke detector in every
room, apart from the kitchen and bathroom, where steam
can cause false alarms.
Fig.1
Fig.2
The smoke detector must be fixed to the ceiling as near to the
centre of the room as possible. One detector can monitor a room
with a maximum floor area of 60 m² with a ceiling height of up to
6 m. In hallways and narrow corridors (up to 3 m wide) the
detector monitors a distance of up to 7.5 m in each direction. A
gap of at least 0.5 m must be maintained from walls and fixtures.
You should therefore install:
• as an absolute necessity one smoke detector in the hallway
(to monitor the escape route) between living and sleeping
areas
• for optimum protection one detector in every living room and
every bedroom
• in multistorey buildings at least one detector on each landing
• in converted lofts one detector above the staircase
Installation on the ceilings of boat cabins or caravans is also
possible. When travelling, simply take the smoke detector with
you into your hotel room.
Unsuitable locations
Never install the smoke detector
• near to ventilation ducting or strong draughts
• directly in the apex of pitched roofs (a minimum distance of 30 cm from the apex must be
maintained)
• in rooms where there is a lot of steam, dust or smoke under normal conditions (workshops,
bathrooms, laundry rooms, for example)
• in rooms where the temperature rises above +40 °C or falls below +5 °C
• in the vicinity of fluorescent luminaires.
Installation and putting into service
Fig.3
The home smoke detector is installed as follows:
• Remove the smoke detector from its base by turning it
anticlockwise.
• Screw the base to the ceiling using the fixing materials
provided (see Fig. 3 for dimensions).
•
A
ttach the 9 V rectangular battery to the connector and insert
it into the battery holder (1).
• Insert the smoke detector into the base, without using force,
and turn it gently clockwise until it clicks into place.
Note: If no battery is fitted, the smoke detector will not click
into place!
• Finally verify the good working order of the smoke detector
by pressing ist test button.
GIRA
Info
Smoke detector plus / VdS
Instructions for Installation
Smoke detector plus / VdS 02/02 Seite: 3 von 6
Networking home smoke detectors
Fig.4
A relay module, available as an optional extra, is required for
networking home smoke detectors. Up to 40 smoke alarms
(relay type) can be networked using a twisted pair of wires
(e.g.telephone cable). For installation see figure 5. A
maximum of 500 metres of a 0.6 mm diameter copper cable
can be used. In addition, external signalling devices such as
sounders or alarm beacons can also be connected.
Note: If a device with an inductive load is connected, a free-
wheeling diode (type 1N4007) must be included in the circuit.
In doubtful cases please consult your local specialist dealer.
Fig.5


Product specificaties

Merk: Gira
Categorie: Rookmelder
Model: 0496 08

Heb je hulp nodig?

Als je hulp nodig hebt met Gira 0496 08 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder Gira

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Kidde

Kidde CO120X Handleiding

2 December 2024
EQ-3

EQ-3 HM-Sec-SD-2 Handleiding

30 November 2024
EQ-3

EQ-3 HM-Sec-SD Handleiding

30 November 2024
EQ-3

EQ-3 HMIP-SWSD Handleiding

30 November 2024
Pentatech

Pentatech RA170Q Handleiding

24 November 2024
Cordes

Cordes CC-4100 Handleiding

18 November 2024
Cordes

Cordes CC-3000 Handleiding

18 November 2024
Cordes

Cordes CC-500 Handleiding

18 November 2024
Nexa

Nexa KD-134A Handleiding

18 November 2024
Gloria

Gloria R-5 Handleiding

16 November 2024