First Alert SMICO110 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor First Alert SMICO110 (2 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
USER’S MANUAL
SMOKE & CARBON MONOXIDE ALARM
10-YEAR SEALED BATTERY
Model SMICO110
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
The warnings/limitations card and manual contains important
information about your Smoke Alarm’s operation. If you are
installing this Alarm for use by others, you must leave this
manual—or a copy of it—with the end user.
Para el manual del usuario en español, por favor
visite rstalert.com
! WARNING!
This unit will not alert hearing impaired residents. It is recommended that you
install special units which use devices like ashing strobe lights to alert hearing
impaired residents.
Do not connect this unit to any other Alarm or auxiliary device. It is a single-station unit
that cannot be linked to other devices. Connecting anything else to this unit may prevent
it from working properly.
Unit will not operate without battery power. The Smoke Alarm cannot work until you
activate the battery power pack.
! CAUTION!
Do not install this unit over an electrical junction box. Air currents around junction boxes
can prevent smoke from reaching the sensing chamber and prevent the unit from
Alarming. Only AC powered units are intended for installation over junction boxes.
Do not stand too close to the unit when the Alarm is sounding. It is loud to wake you in an
emergency. Exposure to the horn at close range may harm your hearing
Do not paint over the unit. Paint may clog the openings to the sensing chamber and
prevent the unit from operating properly.
01 INTRODUCTION
Thank you for choosing First Alert
®
for your Smoke and Carbon Monoxide Alarm needs. You have
purchased a state-of-the-art Smoke & Carbon Monoxide Alarm designed to help provide you with early
warning of a smoke and/or carbon monoxide danger. Please take the time to read this manual and
make the Smoke & Carbon Monoxide Alarm an integral part of your family’s safety plan.
BASIC SAFETY INFORMATION
IMPORTANT!
Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially
hazardous situations. Pay special attention to these items.
This Smoke/CO Alarm is approved for use in single-family residences. It is designed for NOT
marine or RV use.
! CAUTION!
This combination Smoke/Carbon Monoxide Alarm has two separate Alarms. The CO Alarm is not
designed to detect re or any other gas. It will only indicate the presence of carbon monoxide
gas at the sensor. Carbon monoxide gas may be present in other areas. The Smoke Alarm will
only indicate the presence of smoke that reaches the sensor. The Smoke Alarm is not designed to
sense gas, heat or ames.
! WARNING!
ignore any Alarm. See “If Your Smoke/CO Alarm Sounds” for more information on how to NEVER
respond to an Alarm. Failure to respond can result in injury or death.
The Silence Features are for your convenience only and will not correct a problem. See “Using the
Silence Features” for details. Always check your home for a potential problem after any Alarm.
Failure to do so can result in injury or death.
Test this Smoke/CO Alarm once a week. If the Alarm ever fails to test correctly, have it replaced
immediately! If the Alarm is not working properly, it cannot alert you to a problem.
02 ABOUT SMOKE ALARMS
TYPES OF ALARMS
All these Smoke Alarms are designed to provide early warning of res if located, installed and cared
for as described in the user’s manual, and if smoke reaches the Alarm. If you are unsure which type of
Smoke Alarm to install, refer the National Fire Protection Association (NFPA) Standard 72 (National Fire
Alarm and Signaling Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One
Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specic units in
new construction or in different areas of the home.
Battery (DC) operated Smoke Alarms: Provide protection even when electricity fails, provided the
batteries are fresh and correctly installed. Units are easy to install, and do not require professional
installation. They do not, however, provide interconnected functionality.
AC powered Smoke Alarms: Can be interconnected so if one unit senses smoke, all units Alarm.
They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided the batteries are fresh and
correctly installed. AC and AC/DC units must be installed by a qualied electrician.
Wireless Interconnected Alarms: Offer the same interconnected functionality as with hardwired
Alarms, without wires. Units are easy to install and do not require professional installation. They
provide protection even when electricity fails, provided the batteries are fresh and correctly installed.
Smoke Alarms for solar or wind energy users and battery backup power systems: AC powered
Smoke Alarms should only be operated with true or pure sine wave inverters. Operating this Smoke
Alarm with most batterypowered UPS (uninterruptible power supply) products or square wave or
“quasi sine wave” inverters If you are not sure about your inverter or UPS will damage the Alarm.
type, please consult with the manufacturer to verify.
Smoke Alarms for the hearing impaired:
Special purpose Smoke Alarms should be installed for the
hearing impaired. They include a visual Alarm and an audible Alarm horn, and meet the requirements of the
Americans With Disabilities Act. These units can be interconnected so if one unit senses smoke, all units Alarm.
Smoke Alarms are not to be used with detector guards unless the combination has been evaluated
and found suitable for that purpose.
All First Alert
®
Smoke Alarms conform to regulatory requirements, including UL217 and are
designed to detect particles of combustion. Smoke particles of varying number and size are
produced in all res.
Ionization technology is generally more sensitive than photoelectric technology at
detecting small particles, which tend to be produced in greater amounts by aming res,
which consume combustible materials rapidly and spread quickly. Sources of these res
may include paper burning in a wastebasket, or a grease re in the kitchen.
Photoelectric technology is generally more sensitive than ionization technology at
detecting large particles, which tend to be produced in greater amounts by smoldering
res, which may smolder for hours before bursting into ame. Sources of these res may
include cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each level and in every
bedroom of your home.
03 INSTALLATION
WHERE TO INSTALL THIS ALARM
Minimum coverage for Smoke Alarms, as recommended by the National Fire Protection Association
(NFPA), is one Smoke Alarm on every oor, in every sleeping area, and in every bedroom (See
“Regulatory Information For Smoke Alarms” for details on the NFPA recommendations).
For CO Alarms, the National Fire Protection Association (NFPA) recommends that a CO Alarm
should be centrally located outside of each separate sleeping area in the immediate vicinity of the
bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every
level of your home.
NOTE: For added protection, install an additional Smoke/CO Alarm at least 15 feet (4.6 meters) away
from the furnace or fuel burning heat source where possible. In smaller homes or in manufactured
homes where this distance cannot be maintained, install the Alarm as far away as possible from the
furnace or other fuel burning source. Installing the Alarm closer than 15 feet (4.6 meters) will not harm
the Alarm, but may increase the frequency of unwanted Alarms.
IN GENERAL, INSTALL COMBINATION SMOKE AND CARBON MONOXIDE ALARMS:
On every level of your home, including nished attics and basements.
Inside every bedroom, especially if people sleep with the door partly or completely closed.
In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each.
If a hall is more than 40 feet (12 meters) long, install a unit at each end.
At the top of rst-to-second oor stairs.
At the bottom of the basement stairs.
For additional coverage, install Alarms in all rooms, halls, and storage areas, where temperatures
normally remain between 40˚ F and 100˚ F (4.4˚ C and 37.8˚ C).
RECOMMENDED PLACEMENT:
Smoke Alarm
One on every level and
in every bedroom
Carbon Monoxide Alarm
One on every level and
in every bedroom
Fire Extinguisher
One on every level, plus
kitchen and garage
When installing on the wall, the top edge of Smoke Alarms should be placed between 4 inches
(102 mm) and 12 inches (305 mm) from the wall/ceiling line.
When installing on the ceiling, place the Alarm as close to the center as possible.
In either case, install at least 4 inches (102 mm) from where the wall and ceiling meet.
NOTE: For any location, make sure no door or other obstruction could keep carbon monoxide or smoke
from reaching the Alarm.
WHERE NOT TO INSTALL THIS ALARM
FOR BEST PERFORMANCE, IT IS RECOMMENDED YOU AVOID INSTALLING SMOKE/CO ALARMS
IN THESE AREAS:
In garages, furnace rooms, crawl spaces and unnished attics. Avoid extremely dusty, dirty
or greasy areas.
Where combustion particles are produced. Combustion particles form when something burns.
Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at
least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater,
space heater) if possible. In areas where a 20-foot (6 meter) distance is not possible – in modular,
mobile, or smaller homes, for example – it is recommended the Smoke Alarm be placed as far
from these fuel-burning sources as possible. The placement recommendations are intended
to keep these Alarms at a reasonable distance from a fuel-burning source, and thus reduce
“unwanted” Alarms. Unwanted Alarms can occur if a Smoke Alarm is placed directly next to a
fuel-burning source. Ventilate these areas as much as possible.
Within 5 feet (1.5 meters) of any cooking appliance. In air streams near kitchens. Air currents can
draw cooking smoke into the smoke sensor and cause unwanted Alarms.
In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a shower, sauna,
humidier, vaporizer, dishwasher, laundry room, utility room, or other source of high humidity.
In direct sunlight.
In turbulent air, like near ceiling fans or open windows. Blowing air may prevent CO or smoke from
reaching the sensors.
In areas where temperature is colder than 40˚ F (4.4˚ C) or hotter than 100˚ F (37.8˚ C). These
areas include non-airconditioned crawl spaces, unnished attics, uninsulated or poorly insulated
ceilings, porches, and garages.
In insect infested areas. Insects can clog the openings to the sensing chamber.
Less than 12 inches (305 mm) away from uorescent lights. Electrical “noise” can interfere
with the sensor.
In “dead air” spaces.
AVOIDING DEAD AIR SPACES
“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm. To avoid dead air spaces,
follow installation recommendations below.
On ceilings, install Smoke/CO Alarms as close to the center of the ceiling as possible. If this is not
possible, install the Smoke/CO Alarm at least 4 inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke/CO Alarms should be placed
between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line.
On a peaked, gabled, or cathedral ceiling, install the rst Smoke/CO Alarm within 3 feet (0.9
meters) of the peak of the ceiling, measured horizontally. Additional Smoke/CO Alarms may be required
depending on the length, angle, etc. of the ceiling’s slope. Refer to NFPA 72 for details on requirements
for sloped or peaked ceilings.
HOW TO INSTALL THIS ALARM
This unit is designed to be mounted on the ceiling, or
on the wall if necessary.
Tools you will need: pencil, drill with 3/16" (5 mm)
drill bit, standard athead screwdriver, hammer.
THE PARTS OF THIS SMOKE/CO ALARM
A Smoke/CO LED (RED)
B Power LED (GREEN)
C Test/Silence button
1 Mounting Bracket
2 Locking pins
(break out of bracket)
3 Mounting Slots
4 Turn this way to remove
5 Turn this way to attach
FOLLOW THESE SIMPLE STEPS
1. Choose a location. See “Where to Install This
Alarm” for reference.
2
3
1
5
4
A
B
C
WARNING! Do not install this Alarm over an existing
electrical box. Only AC powered units are intended for
installation over electrical boxes.
2. Hold the bracket against the ceiling or wall and make a mark
inside each hole where you will drill your mounting hole. To
install on the wall, ensure that the round portions of the holes
are vertical. Put the Alarm where it won’t get covered with dust
while you drill the holes.
3. Use a 3/16" (5mm) drill bit to drill through the marks you made
for the mounting holes.
Mounting Hole Sets
4. Insert the plastic screw anchors (in the plastic bag with the screws) into the holes. Tap the screw
anchors gently with a hammer, if necessary, until they are ush with the ceiling or wall.
5. Insert the screws but do not tighten completely. Leave them about 1/8” (3mm) away from the wall.
6. Position the base of the Smoke Alarm over the mounting bracket and turn. The Alarm can be
positioned over the bracket every 120°. Turn the Smoke Alarm clockwise (right) until the unit is in
place. Battery will activate when attached to the mounting bracket.
7. Test the Smoke Alarm. See “Weekly Testing.”
Action What You Will See & Hear
Normal Operations Horn: Power LED: Silent; Flashes Green every minute;
Smoke/CO LED: Off
When You Test the Alarm
Horn: 3 beeps, pause, 3 beeps, followed by,
4 beeps, pause, 4 beeps; Power LED: Off;
Smoke/CO LED: Flashes Red in sync with horn.
If Battery Becomes Low Horn: Chirps 5 times every minute; Flashes Power LED:
Green 1 time every minute; OffSmoke/CO LED:
If Alarm is Not
Operating Properly
(MALFUNCTION SIGNAL)
Horn: Power LED: 3 chirps every minute; 3
Green Flashes approximately once a minute;
Smoke/CO LED: Off
Alarm has reached
its End of Life
Horn: Power LED: 5 chirps every minute; 5
Green Flashes approximately once a minute;
Smoke/CO LED: Off
Smoke is Detected
Horn: 3 beeps, pause, repeating; Off; Power LED:
Smoke/CO LED: Flashes Red in sync with
the horn pattern.
Smoke Alarm is Silenced Horn: Power LED: Off (for up to 15 minutes); Off;
Smoke/CO LED: Flashes Red
Alarm Levels of CO
are Detected
Horn: 4 fast beeps, pause, repeating;
Power LED: Smoke/CO LED: Off; Flashes Red in
sync with the horn pattern.
CO Alarm is Silenced Horn: Power LED: Off (for up to 6 minutes); Off;
Smoke/CO LED: Flashes Red
04 ALARM FEATURES
Add protection in minutesEasy Installation:
Or low battery chirps for the life of the Alarm.No Battery Replacements:
Lets you know when its time to replace.End of Life Warning:
OPTIONAL LOCKING FEATURE
The optional locking feature is designed to prevent unauthorized removal of the Alarm. It is
not necessary to activate the lock in single-family households where unauthorized Alarm
removal is not a concern.
Tools you will need: Needle-nose pliers or utility
knife, standard athead screwdriver
The feature uses a locking pin which is molded
into the mounting bracket. Remove locking pin by
using needle-nose pliers or a utility knife.
Locking Pin
IMPORTANT!
To permanently remove the locking pin, insert a athead screwdriver between the
locking pin and the lock and pry the pin out of the lock.
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose
pliers, detach one
locking pin from
mounting bracket.
2. Insert the locking
pin into the lock.
3. When you attach the
Alarm to the mounting
bracket, the locking
pin’s head will t into a
notch on the bracket.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a athead screwdriver
between the mounting bracket
pin and the mounting bracket.
2. Pry the Alarm away from
the bracket by turning both
the screwdriver and the
Alarm counterclockwise (left)
at the same time.
TO PERMANENTLY DEACTIVATE THE SMOKE/CO ALARM
! WARNING!
Alarm is sealed. The powercell is not replaceable. Once it reaches the end of its service life, or
after 10 years—whichever comes rstyou must install a new Smoke/CO Alarm.
After 10 years or after the “low power warning” sounds (whichever comes rst):
1. Once you deactivate this unit, it will not detect smoke or carbon monoxide, or alarm. It cannot be
reactivated. You must install a new unit to continue your protection. Alarm will resist mounting to
the bracket after deactivation.
2. Use a athead screwdriver to score label
along dotted line.
3. Use thumb to pull deactivation tab outward until tab
snaps into place. This will discharge the powercell
and deactivate the unit.
4. Install a new Smoke/CO Alarm immediately!
05 TESTING & MAINTENANCE
WEEKLY TESTING
! WARNING!
use an open ame of any kind to test this unit. You might accidentally damage or set re NEVER
to the unit or to your home. use vehicle exhaust! Exhaust may cause permanent damage NEVER
and voids your warranty.
stand close to the Alarm when the horn is sounding. Exposure at close range may be DO NOT
harmful to your hearing. When testing, step away when horn starts sounding.
! CAUTION!
It is important to test this unit every week to make sure it is working properly. Using the test
button is the recommended way to test this Smoke/CO Alarm.
1. Push and release the Test/Silence button on the cover until you hear a “chirp.” The “chirp” marks
the start of the self-test sequence.
2. During testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause, while
the red smoke LED ashes. Then you will hear a loud, repeating horn pattern: 4 beeps, pause, 4
beeps, pause, while the red CO LED ashes.
If the Smoke/CO Alarm does not test properly:
1. Make sure the battery installed correctly.
2. Be sure the Alarm is clean and dust-free.
3. Test the unit again.
If the Smoke/CO Alarm is still not working properly, replace it immediately. Refer to the
“Limited Warranty” at the end of this manual.
! WARNING!
If there is still a problem, do not try to x the Alarm yourself. This will void your warranty!
REGULAR MAINTENANCE
This unit has been designed to be as maintenance-free as possible, but there are a few simple things
you must do to keep it working properly:
Test it at least once a week.
Clean the Smoke/CO Alarm at least once a month; gently vacuum the outside of the Smoke/CO
Alarm using your household vacuum’s soft brush attachment. Test the Smoke/CO Alarm. Never use
water, cleaners or solvents since they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be
cleaned to avoid unwanted Alarms, replace the unit immediately.
If the green power LED ashes 2 times every minute (horn is silent) it means that the Alarm needs
to be cleaned as indicated above. If green light continues to ash, replace Alarm.
Relocate the unit if it sounds frequent unwanted Alarms. See “Where This Alarm Should Not Be
Installed” for details.
Protect or cover the alarm when doing any maintenance to home i.e. sanding oors, painting,
drywall patching, etc. to prevent contamination.
! WARNING!
DO NOT spray cleaning chemicals or insect sprays directly on our near the Alarm. paint over DO NOT
the Alarm. Doing so may permanently damage the Alarm.
TROUBLESHOOTING GUIDE
IF THE ALARM... PROBLEM... YOU SHOULD...
Green Power LED is OFF.
Unit will not Alarm when you
press the Test/Silence button.
Battery may be dead
or missing.
Replace Alarm
Hornchirps 5 times and
Green Power LED ashes 1
time every minute.
Low Battery Signal. Alarm
needs to be replaced.
Replace Alarm
Horn “chirps” and Green
Power LED ashes 3
times every minute
MALFUNCTION SIGNAL.
Device is not working
properly, and needs
to be replaced.
If unit is under warranty,
contact Consumer
Support to process a
warranty replacement.
Hornchirps 5 times and
Green Power LED ashes 5
times every minute
END OF LIFE SIGNAL.
Alarm needs
to be replaced.
Immediately
replace the Alarm.
Alarm goes back into
Alarm after you pressed
the Test/Silence button to
silence an Alarm.
Smoke and/or
CO levels are still
potentially dangerous.
Refer to “If Your Smoke/CO
Alarm Sounds” for details
on how to respond to an
Alarm. If anyone is feeling
ill, EVACUATE your home
immediately and call 911.
Power LED ashes Green 2
times every minute. Alarm requires cleaning.
Clean Alarm then press
and release the test button.
See Regular Maintenance
section. If Green LED
Continues to ash, contact
Consumer Support.
CARBON MONOXIDE ALARM ONLY
CO Alarm goes back into
Alarm 4 minutes after
you Silence it.
CO levels indicate
a potentially
dangerous situation.
IF YOU ARE FEELING
SYMPTOMS OF CO
POISONING, EVACUATE your
home and call 911 or the Fire
Department. Refer to “If The
CO Alarm Sounds” for details.
CO Alarm sounds frequently
even though no high levels
of CO are revealed in
an investigation.
The CO Alarm may be
improperly located. Refer
to “Where to Install This
Alarm” for details.
Relocate your Alarm. If
frequent Alarms continue,
have home rechecked for
potential CO problems. You
may be experiencing an
intermittent CO problem.
SMOKE ALARM ONLY
Smoke Alarm sounds when
no smoke is visible.
Unwanted Alarm may be
caused by nonemergency
source like cooking smoke.
Silence Alarm using manual
button; clean the Alarm’s
cover with a soft, clean
cloth. If frequent unwanted
Alarms continue, relocate
your Alarm. Alarm may
be too close to a kitchen,
cooking appliance, or
steamy bathroom.
If you have questions that cannot be answered by reading this manual, call the
Consumer Support Team at 1-800-323-9005
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking materials properly. Never smoke
in bed. 2) Keep matches or lighters away from children; 3) Store ammable materials in proper
containers; 4) Keep electrical appliances in good condition and don’t overload electrical circuits;
5) Keep stoves, barbecue grills, replaces and chimneys grease- and debris-free; 6) Never leave
anything cooking on the stove unattended; 7) Keep portable heaters and open ames, like candles,
away from ammable materials; 8) Don’t let rubbish accumulate. Keep Alarms clean, and test them
weekly. Replace Alarms immediately if they are not working properly. Smoke Alarms that do not work
cannot alert you to a re. Keep at least one working re extinguisher on every level, and an additional
one in the kitchen. Have re escape ladders or other reliable means of escape from an upper level in
case stairs are blocked; 9) Have an escape plan and practice it regularly.
06 IF YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST: IDENTIFY THE TYPE OF ALARM SIGNAL
Refer to previous section “What You Will See And Hear With This Alarm”.
IF THE CO ALARM SOUNDS
! WARNING!
Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In
other words, when your CO Alarm sounds, you must not ignore it!
IF THE CO ALARM SIGNAL SOUNDS:
1. Press the Test/Silence button.
2. Call your emergency services, re department or 911. Write down the number of your local
emergency service here:
____________________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check
that all persons are accounted for. Do not re-enter the premises, or move away from the open door
or window until the emergency services responder has arrived, the premises have been aired out,
and your CO Alarm remains in its normal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps
1-3 and call a qualied appliance technician to investigate for sources of CO from fuel-burning
equipment and appliances, and inspect for proper operation of this equipment. If problems are
identied during this inspection have the equipment serviced immediately. Note any combustion
equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact
the manufacturers directly, for more information about CO safety and this equipment. Make sure
that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the
residence. Write down the number of a qualied appliance technician here:
____________________________________________________________________
NOTE: A qualied appliance technician is dened as “a person, rm, corporation, or company that
either in person or through a representative, is engaged in and responsible for the installation, testing,
servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion
appliances and equipment, and/or gas replaces or other decorative combustion equipment.”
IF THE SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
! WARNING!
If the unit Alarms and you are not testing the unit, it is warning you of a potentially dangerous
situation that requires your immediate attention. ignore any Alarm. Ignoring the Alarm may NEVER
result in injury or death.
Never remove the batteries from a battery operated Smoke/CO Alarm to stop an unwanted Alarm
(caused by cooking smoke, etc.). Removing batteries disables the Alarm so it cannot sense smoke,
and removes your protection. Instead open a window or fan the smoke away from the unit. The
Alarm will reset automatically.
If the unit Alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.
Feel doors with the back of your hand before opening them. If a door is cool, open it slowly. Don’t
open a hot door. Keep doors and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.
Meet at your planned meeting place outside your home, and do a head count to make sure
everybody got out safely.
Call the Fire Department as soon as possible from outside. Give your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
! WARNING!
Alarms have various limitations. See “General Limitations of Smoke/CO Alarms” for details.
07 USING THE SILENCE FEATURES
! WARNING!
The Silence Feature does not disable the unit—it makes it temporarily less sensitive to smoke. For
your safety, if smoke around the unit is dense enough to suggest a potentially dangerous situation,
the unit will stay in Alarm or may re-Alarm quickly. If you do not know the source of the smoke, do
not assume it is an unwanted Alarm. Not responding to an Alarm can result in property loss, injury,
or death. If the unit will not silence and no heavy smoke is present, or if it stays in silence mode
continuously, it should be replaced immediately.
Never remove the batteries to quiet an unwanted Alarm. Removing the batteries disables the
Alarm and removes your protection.
The Silence Feature is intended to temporarily silence the horn while you identify and correct the
problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem
or extinguish a re.
The Silence Feature can temporarily quiet an unwanted Alarm for several minutes. You can silence
this Smoke/CO Alarm by pressing the Test/Silence button on the Alarm cover.
Activate the Alarm test, reset or silence function by use of a nger or thumb. Use of any other
instrument is strictly prohibited.
When the Smoke Alarm is Silenced When the CO Alarm is Silenced
The Smoke Alarm will remain silent
for up to 15 minutes, then returns to
normal operation.
If the smoke has not cleared–or continues to
increase–the device will go back into Alarm.
The CO Alarm will remain silent for
up to 6 minutes.
After 6 minutes, if CO levels remain
potentially dangerous the horn will start
sounding again.
SILENCING THE END OF LIFE SIGNAL
This Silence Feature can temporarily quiet the End of Life warning “chirp” for up to 2 days. You
can silence the End of Life warning “chirp” by pressing the Test/Silence button. The horn will chirp,
acknowledging that the End of Life Silence Feature has been activated.
After approximately 2 days, the End of Life “chirp” will resume. The timer shall not be able to be reset
after 14 days following the initial end-of-life signal.
08 WHAT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are
exposed to heat (usually re). Electrical appliances typically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.
Common appliances are often sources of CO. If they are not properly maintained, are improperly
ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more
energy efcient. “Air-tight” homes with added insulation, sealed windows, and other weatherproong
can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed with ALL household members.
Mild Exposure: Slight headache, nausea, vomiting, fatigue (“u-like” symptoms).
Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to carbon
monoxide can cause brain damage, death.
IMPORTANT!
This CO Alarm measures exposure to CO over time. It Alarms if CO levels are extremely high in a
short period of time, or if CO levels reach a certain minimum over a long period of time. The CO
Alarm generally sounds an Alarm before the onset of symptoms in average, healthy adults. Why is
this important? Because you need to be warned of a potential CO problem while you can still react in
time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but
become disoriented and can no longer react well enough to exit the building or get help. Also, young
children and pets may be the rst affected. The average healthy adult might not feel any symptoms
when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn
babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you
experience even mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it difcult to locate the source of CO
after an Alarm. These are a few of the factors that can make it difcult to locate sources of CO:
House well ventilated before the investigator arrives.
Problem caused by “backdrafting.”
Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be difcult to locate the
source of CO. First Alert shall not be obligated to pay for any carbon monoxide investigation
or service call.
POTENTIAL SOURCES OF CO IN THE HOME
Fuel-burning appliances like:
portable heater, gas or wood
burning replace, gas kitchen range
or cooktop, gas clothes dryer.
Damaged or insufcient venting:
corroded or disconnected water
heater vent pipe, leaking chimney
pipe or ue, or cracked heat
exchanger, blocked or clogged
chimney opening.
Improper use of appliance/
device: operating a barbecue grill
or vehicle in an enclosed area (like
a garage or screened porch).
Transient CO problems: transient or on-again-off-again CO problems can be caused by outdoor
conditions and other special circumstances.
The following conditions can result in transient CO situations:
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air
with extended periods between cycles).
Negative pressure differential resulting from the use of exhaust fans.
Several appliances running at the same time competing for limited fresh air.
Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
Obstructions in or unconventional vent pipe designs which can amplify the above situations.
2. Extended operation of unvented fuel burning devices (range, oven, replace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your home. Since these
conditions can come and go, they are also hard to recreate during a CO investigation.
09 HOW CAN I PROTECT MY FAMILY FROM
CO POISONING
A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud Alarm before
carbon monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute
for proper maintenance of home appliances.
TO HELP PREVENT CO PROBLEMS AND REDUCE THE RISK OF CO POISONING:
Clean chimneys and ues yearly. Keep them free of debris, leaves, and nests for proper air ow.
Also, have a professional check for rust and corrosion, cracks, or separations. These conditions
can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any
way that would block air ow.
Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC
companies offer appliance inspections for a nominal fee.
Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust
and scaling. Also check the ame on the burner and pilot lights. The ame should be blue. A yellow
ame means fuel is not being burned completely and CO may be present. Keep the blower door
on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances.
Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or
on screen porches.
Check for exhaust backow from CO sources. Check the draft hood on an operating furnace for a
backdraft. Look for cracks on furnace heat exchangers.
Check the house or garage on the other side of shared wall.
Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a
window or a door. Opening windows and doors can signicantly decrease CO levels.
In addition, familiarize yourself with all enclosed materials. Read this manual in its entirety, and make
sure you understand what to do if your CO Alarm sounds.
10 REGULATORY INFORMATION
FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
INSTALLING SMOKE ALARMS IN SINGLE-FAMILY RESIDENCES
The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every oor, in every
sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC powered and
interconnected. See “Agency Placement Recommendations” for details. For additional coverage, it is
recommended that you install a Smoke Alarm in all rooms, halls, storage areas, nished attics, and
basements, where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚ C). Make
sure no door or other obstruction could keep smoke from reaching the Smoke Alarms.
MORE SPECIFICALLY, INSTALL SMOKE ALARMS:
On every level of your home, including nished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each.
If a hall is over 40 feet (12 meters) long, install an Alarm at each end.
At the top of the rst-to-second level stairway, and at bottom of basement stairway.
IMPORTANT!
Specic requirements for Smoke Alarm installation vary from state to state and from region to region.
Check with your local Fire Department for current requirements in your area. It is recommended AC
or AC/DC units be interconnected for added protection.
HARDWIREDBATTERY OPERATED & WIRELESS
MULTI-STORY RESIDENCE
1-STORY RESIDENCE
Wireless Alarms
Wireless Interconnected Alarms
Hardwired Interconnected
AC or AC/DC Alarms
Smoke Alarms
CO Alarms
Both OR Combination
Smoke/CO Alarms
11 REGULATORY INFORMATION FOR CO ALARMS
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when
exposed to levels of CO and exposure times as described below. They are measured in parts per
million (ppm) of CO over time (in minutes).
UL2034 Required Alarm Points*:
If the Alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.
If the Alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
If the Alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH).
The unit is designed not to Alarm when exposed to a constant level of 30 ppm for 30 days.
IMPORTANT!
CO Alarms are designed to Alarm before there is an immediate life threat. Since you cannot see or
smell CO, never assume its not present.
An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4
hours the same level may cause headaches.
An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes,
but can cause death after 2 hours.
Standards: Underwriters Laboratories Inc. Single and Multiple Station Carbon
Monoxide Alarms UL2034.
According to Underwriters Laboratories Inc. UL2034, Section 1-1. 2: “Carbon monoxide Alarms covered
by these requirements are intended to respond to the presence of carbon monoxide from sources
such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-red
appliances, and replaces. CO Alarms are intended to Alarm at carbon monoxide levels below those
that could cause a loss of ability to react to the dangers of carbon monoxide exposure. ” This CO Alarm
monitors the air at the Alarm, and is designed to Alarm before CO levels become life threatening. This
allows you precious time to leave the house and correct the problem. This is only possible if Alarms
are located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to
detect CO levels below 30 ppm typically. UL tested for false Alarm resistance to Methane (500 ppm),
Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and
Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
12 AGENCY PLACEMENT RECOMMENDATIONS
Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke Alarms 217.
NFPA 72 CHAPTER 29 “FOR YOUR INFORMATION, THE NATIONAL FIRE ALARM AND SIGNALING
CODE, NFPA 72, READS AS FOLLOWS:”
29.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards for a specic type of
occupancy, approved single and multiple-station Smoke Alarms shall be installed as follows:
1. *In all sleeping rooms and guest rooms
2. *Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door to a
sleeping room, with the distance measured along a path of travel
3. On every level of a dwelling unit, including basements
4. On every level of a residential board and care occupancy (small facility), including basements and
excluding crawl spaces and unnished attics
5. *In the living area(s) of a guest suite
6. In the living area(s) of a residential board and care occupancy (small facility)
(Reprinted with permission from NFPA 72
®
, National Fire Alarm and Signaling Code Copyright © 2012
National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete
and ofcial position of the National Fire Protection Association, on the referenced subject which is
represented only by the standard in its entirety).
(National Fire Alarm and Signaling Code
®
and NFPA 72
®
are registered trademarks of the National Fire
Protection Association, Inc., Quincy, MA 02269).
CALIFORNIA STATE FIRE MARSHAL (CSFM)
Early warning detection is best achieved by the installation of re detection equipment in all rooms
and areas of the household as follows: A Smoke Alarm installed in each separate sleeping area (in
the vicinity, but outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms,
bedrooms, kitchens, hallways, nished attics, furnace rooms, closets, utility and storage rooms,
basements, and attached garages.
13 SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm is suitable for use in apartments, condominiums, townhouses, hospitals, day care
facilities, health care facilities, boarding houses, group homes and dormitories provided a primary re
detection system already exists to meet re detection requirements in common areas like lobbies,
hallways, or porches. Using this Smoke Alarm in common areas may not provide sufcient warning to
all residents or meet local re protection ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete re detection systems in places
housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals,
health care facilities, nursing homes, day care facilities, or group homes of any kind. It is not a
suitable substitute for complete re detection systems in warehouses, industrial facilities, commercial
buildings, and special-purpose non-residential buildings which require special re detection and Alarm
systems. Depending on the building codes in your area, this Smoke Alarm may be used to provide
additional protection in these facilities.
In new construction, most building codes require the use of AC or AC/DC powered Smoke Alarms only.
In existing construction, AC, AC/DC, or DC powered Smoke Alarms can be used as specied by local
building codes. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION’S STANDARD 72 (National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269). Refer to NFPA 101 (Life Safety Code), local building codes, or consult your Fire
Department for detailed re protection requirements in buildings not dened as “households”.
FCC COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that the interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that of the receiver.
Consult the dealer or an experienced radio or TV technician for help.
! WARNING!
Changes or modications to the product, not expressly approved by First Alert, could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
14 GENERAL LIMITATIONS OF
SMOKE/CO ALARMS
This Smoke/CO Alarm is intended for residential use. This product is intended for use in ordinary
indoor locations of family living units. It is not designed to measure CO levels in compliance with
Occupational Safety and Health Administration (OSHA) commercial or industrial standards. Individuals
with medical conditions that may make them more sensitive to carbon monoxide may consider
using warning devices which provide audible and visual signals for carbon monoxide concentrations
under 30 ppm. For additional information on carbon monoxide and your medical condition contact
your physician.
Smoke/CO Alarms may not waken all individuals. Practice the escape plan at least twice a year,
making sure that everyone is involved – from kids to grandparents. Allow children to master re
escape planning and practice before holding a re drill at night when they are sleeping. If children
or others do not readily waken to the sound of the Smoke/CO Alarm, or if there are infants or family
members with mobility limitations, make sure that someone is assigned to assist them in re drill and
in the event of an emergency. It is recommended that you hold a re drill while family members are
sleeping in order to determine their response to the sound of the Smoke/CO Alarm while sleeping and
to determine whether they may need assistance in the event of an emergency.
Smoke/CO Alarms cannot work without power. Battery operated units cannot work if the batteries
are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not
installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit
breaker, failure along a power line or at a power station, electrical re that burns the electrical wires,
etc.). If you are concerned about the limitations of battery or AC power, install both types of units.
This Smoke/CO Alarm will not sense smoke or CO that does not reach the sensors. It will
only sense smoke or CO at the sensor. Smoke or CO may be present in other areas. Doors or other
obstructions may affect the rate at which CO or smoke reaches the sensors. If bedroom doors are
usually closed at night, we recommend you install an Alarm device (Combination CO and Smoke Alarm,
or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them.
This Smoke/CO Alarm may not sense smoke or CO on another level of the home. Example:
This Alarm device, installed on the second oor, may not sense smoke or CO in the basement.
For this reason, one Alarm device may not give adequate early warning. Recommended minimum
protection is one Alarm device in every sleeping area, every bedroom, and on every level of your
home. Some experts recommend battery powered smoke and CO Alarms be used in conjunction with
interconnected AC powered Smoke Alarms. For details, see “About Smoke Alarms” for details.
Smoke/CO Alarms may not be heard. The Alarm horn loudness meets or exceeds current UL
standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO Alarm is installed outside the
bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been
drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even
persons who are awake may not hear the Alarm horn if the sound is blocked by distance or closed
doors. Noise from trafc, stereo, radio, television, air conditioner, or other appliances may also prevent
alert persons from hearing the Alarm horn. This Smoke/CO Alarm is not intended for people who are
hearing impaired.
The Alarm may not have time to Alarm before the re itself causes damage, injury, or death,
since smoke from some res may not reach the unit immediately. Examples of this include
persons smoking in bed, children playing with matches, when a person’s clothing catches re
while cooking, res caused by violent explosions resulting from escaping gas, or incendiary
res where the re grows so rapidly that an occupant’s egress is blocked even with properly
located Smoke Alarms.
This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns
against increasing CO levels or the presence of smoke, First Alert does not warrant or imply in any way
that they will protect lives. Homeowners and renters must still insure their lives.
This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm and all of its parts have
passed many stringent tests and are designed to be as reliable as possible, any of these parts could
fail at any time. Therefore, you must test this device weekly. The unit should be replaced immediately
if it is not operating properly.
This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has
limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning of
the source of smoke or CO is in a remote part of the home, away from the Alarm device.
15 LIMITED WARRANTY
First Alert
®
warrants that for a period of ten years from the date of purchase, this product will be free
from defects in material and workmanship. First Alert, at its option, will repair or replace this product
or any component of the product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component. If the product is no longer
available, replacement may be made with a similar product of equal or greater value. This is your
exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is
not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty
performance. First Alert dealers, service centers, or retail stores selling First Alert products do not have
the right to alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following:
negligent use or misuse of the product, use on improper voltage or current, use contrary to the
operating instructions, disassembly, repair or alteration by anyone other than First Alert or an
authorized service center. Further, the warranty does not cover Acts of God, such as re, ood,
hurricanes and tornadoes.
First Alert shall not be liable for any incidental or consequential damages caused by the breach of any
express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty
of merchantability or tness for a particular purpose is limited in duration to the duration of the above
warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental
or consequential damages or limitations on how long an implied warranty lasts, so the above
limitations or exclusion may not apply to you. This warranty gives you specic legal rights, and you
may also have other rights that vary from state to state or province to province.
HOW TO OBTAIN WARRANTY SERVICE
Service: If service is required, do not return the product to your retailer. In order to obtain warranty
service, contact the Consumer Support Team at 1-800-323-9005. To assist us in serving you, please
have the model number and date of purchase available when calling.
Disposal: Please follow local guidelines regarding the disposal or recycling of batteries
and/or electronics.
The Alarm should be deactivated before disposal. See, “To Permanently Deactivate the
Smoke/CO Alarm”.
For your records, please record:
Date Purchased: ___________________________
Where Purchased: __________________________
Date Installed: __________/__________Month/Year
Replace Alarm 10 years after installation.
Please write the date in the space provided:_____________/____________ Month/Year
The Alarm will also provide an audible End-of-Life Signal approximately 10 years after
installation to remind you to replace the unit.
The End-of-Life Signal can be silenced for up to 2 days. Do not deactivate the Alarm until you
get replacement.
Printed in Mexico | M08-170691 01/23
CONFORMS TO UL STD 217 AND UL STD 2034
rstalert.com
K1 © 2023 Resideo Technologies, Inc. All rights reserved. These products are
manufactured by Resideo Technologies, Inc. and its afliates. 3901 Liberty Street,
Aurora, IL 60504-8122. Consumer Support Team: (800) 323-9005 | rstalert.com


Product specificaties

Merk: First Alert
Categorie: Rookmelder
Model: SMICO110

Heb je hulp nodig?

Als je hulp nodig hebt met First Alert SMICO110 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder First Alert

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Logilink

Logilink SC0016 Handleiding

29 Januari 2025
Kidde

Kidde CO120X Handleiding

2 December 2024
EQ-3

EQ-3 HM-Sec-SD-2 Handleiding

30 November 2024
EQ-3

EQ-3 HM-Sec-SD Handleiding

30 November 2024
EQ-3

EQ-3 HMIP-SWSD Handleiding

30 November 2024
Pentatech

Pentatech RA170Q Handleiding

24 November 2024
Cordes

Cordes CC-4100 Handleiding

18 November 2024
Cordes

Cordes CC-3000 Handleiding

18 November 2024
Cordes

Cordes CC-500 Handleiding

18 November 2024