First Alert SMI100 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor First Alert SMI100 (1 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 3 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
USER’S MANUAL
SMOKE ALARM
BATTERY OPERATED
Model SMI100
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
The warnings/limitations card and manual contains important
information about your Smoke Alarm’s operation. If you are
installing this Alarm for use by others, you must leave this
manual—or a copy of it—with the end user.
Para el manual del usuario en español, por favor
visite rstalert.com
! WARNING!
This unit will not alert hearing impaired residents. It is recommended that you
install special units which use devices like ashing strobe lights to alert hearing
impaired residents.
Do not connect this unit to any other Alarm or auxiliary device. It is a single-station unit
that cannot be linked to other devices. Connecting anything else to this unit may prevent
it from working properly.
Unit will not operate without battery power. The Smoke Alarm cannot work until you install
the battery in the correct position (Match “+” to “+” and “-” to “-”).
! CAUTION!
Do not install this unit over an electrical junction box. Air currents around junction boxes
can prevent smoke from reaching the sensing chamber and prevent the unit from
Alarming. Only AC powered units are intended for installation over junction boxes.
Do not stand too close to the unit when the Alarm is sounding. It is loud to wake you in an
emergency. Exposure to the horn at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the sensing chamber and
prevent the unit from operating properly.
01 INTRODUCTION
Thank you for choosing First Alert
®
for your Smoke Alarm needs. You have purchased a state-of-the-
art Smoke Alarm designed to provide you with early warning of a re. Please take the time to read this
manual and make the Smoke Alarm an integral part of your family’s safety plan.
BASIC SAFETY INFORMATION
IMPORTANT!
Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially
hazardous situations. Pay special attention to these items.
This Smoke Alarm is approved for use in single-family residences. It is designed for NOT
marine or RV use.
! CAUTION!
The Smoke Alarm will only indicate the presence of smoke that reaches the sensor.
The Smoke Alarm is not designed to sense gas, heat or ames.
! WARNING!
This Smoke Alarm cannot operate without working batteries. Removing the batteries for any
reason, or failing to replace the batteries at the end of their service life, removes your protection.
ignore any Alarm. See “If Your Smoke Alarm Sounds” for more information on how to NEVER
respond to an Alarm. Failure to respond can result in injury or death.
The Silence Features are for your convenience only and will not correct a problem. See “Using the
Silence Features” for details. Always check your home for a potential problem after any Alarm. Failure
to do so can result in injury or death.
Test this Smoke Alarm once a week. If the Alarm ever fails to test correctly, have it replaced
immediately! If the Alarm is not working properly, it cannot alert you to a problem.
02 ABOUT SMOKE ALARMS
TYPES OF ALARMS
All these Smoke Alarms are designed to provide early warning of res if located, installed and cared
for as described in the user’s manual, and if smoke reaches the Alarm. If you are unsure which type of
unit to install, refer to NFPA (National Fire Protection Association) 72 (National Fire Alarm and Signaling
Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269-9101. Local building codes may also require specic units in new construction or in
different areas of the home.
Battery (DC) operated Smoke Alarms: Provide protection even when electricity fails, provided the
batteries are fresh and correctly installed. Units are easy to install, and do not require professional
installation. They do not, however, provide interconnected functionality.
AC powered Smoke Alarms: Can be interconnected so if one unit senses smoke, all units Alarm.
They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided the batteries are fresh and
correctly installed. AC and AC/DC units must be installed by a qualied electrician.
Smoke Alarms for Solar or wind energy users and battery backup power systems: AC powered
Smoke Alarms should only be operated with true or pure sine wave inverters. Operating this Smoke
Alarm with most battery powered UPS (uninterruptible power supply) products or square wave or
“quasi sine wave” inverters . If you are not sure about your inverter or UPS will damage the Alarm
type, please consult with the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms should be installed for the
hearing impaired. They include a visual Alarm and an audible Alarm horn, and meet the requirements
of the Americans with Disabilities Act. These units can be interconnected so if one unit senses smoke,
all units Alarm.
Smoke Alarms are not to be used with detector guards unless the combination has been evaluated
and found suitable for that purpose.
All First Alert
®
Smoke Alarms conform to regulatory requirements, including UL217 and are
designed to detect particles of combustion. Smoke particles of varying number and size are
produced in all res.
Ionization technology is generally more sensitive than photoelectric technology at
detecting small particles, which tend to be produced in greater amounts by aming res,
which consume combustible materials rapidly and spread quickly. Sources of these res
may include paper burning in a wastebasket, or a grease re in the kitchen.
Photoelectric technology is generally more sensitive than ionization technology at
detecting large particles, which tend to be produced in greater amounts by smoldering
res, which may smolder for hours before bursting into ame. Sources of these res may
include cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each level and in every
bedroom of your home.
03 INSTALLATION
WHERE TO INSTALL THIS ALARM
The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every oor, in every
sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC powered and
interconnected. See “Agency Placement Recommendations” for details. For additional coverage, it is
recommended that you install a Smoke Alarm in all rooms, halls, storage areas, nished attics, and
basements, where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚ C). Make
sure no door or other obstruction could keep smoke from reaching the Smoke Alarms.
IN GENERAL, INSTALL SMOKE ALARMS:
On every level of your home, including nished attics and basements.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each.
If a hall is over 40 feet (12 meters) long, install an Alarm at each end.
At the top of the rst-to-second level stairway, and at bottom of basement stairway.
IMPORTANT!
Specic requirements for Smoke Alarm installation vary from state to state and from region to region.
Check with your local Fire Department for current requirements in your area. It is recommended AC
or AC/DC units be interconnected for added protection.
RECOMMENDED PLACEMENT:
Smoke Alarm
One on every level and
in every bedroom
Carbon Monoxide Alarm
One on every level and
in every bedroom
Fire Extinguisher
One on every level, plus
kitchen and garage
WHERE NOT TO INSTALL THIS ALARM
FOR BEST PERFORMANCE, IT IS RECOMMENDED YOU AVOID INSTALLING SMOKE ALARMS
IN THESE AREAS:
Where combustion particles are produced. Combustion particles form when something burns.
Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at least
20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space
heater) if possible. In areas where a 20-foot (6-meter) distance is not possible – in modular,
mobile, or smaller homes, for example – it is recommended the Smoke Alarm be placed as far
from these fuel-burning sources as possible. The placement recommendations are intended
to keep these Alarms at a reasonable distance from a fuel-burning source, and thus reduce
“unwanted” Alarms. Unwanted Alarms can occur if a Smoke Alarm is placed directly next to a
fuel-burning source. Ventilate these areas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke into the sensing chamber of a
Smoke Alarm near the kitchen.
In very damp, humid or steamy areas, or directly near bathrooms with showers. Keep units at least
10 feet (3 meters) away from showers, saunas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4.4˚ C) or above 100˚ F (37.8˚ C), including
unheated buildings, outdoor rooms, porches, or unnished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm directly over the stove or range.
Keep laundry room Smoke Alarms free of dust or lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can blow smoke away from the
unit, preventing it from reaching the sensing chamber.
In insect infested areas. Insects can clog openings to the sensing chamber and cause
unwanted Alarms.
Less than 12 inches (305mm) away from uorescent lights. Electrical “noise” can interfere
with the sensor.
In “dead air” spaces. “Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
AVOIDING DEAD AIR SPACES
“Dead air” spaces may prevent smoke from reaching the Smoke Alarm. To avoid dead air spaces,
follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling as possible. If this is not
possible, install the Smoke Alarm at least 4 inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke Alarms should be placed
between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line, below typical
“dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the rst Smoke Alarm within 3 feet (0.9 meters) of
the peak of the ceiling, measured horizontally. Additional Smoke Alarms may be required depending
on the length, angle, etc. of the ceiling’s slope. Refer to NFPA 72 for details on requirements for sloped
or peaked ceilings.
HOW TO INSTALL THIS ALARM
This unit is designed to be mounted on the ceiling, or
on the wall if necessary.
Tools you will need: pencil, drill with 3/16" (5 mm)
drill bit, standard athead screwdriver, hammer.
THE PARTS OF THIS SMOKE ALARM
A Smoke LED (RED)
B Power LED (GREEN)
C Test/Silence button
ABC
1 Mounting Bracket
2 Locking pins
(break out of bracket)
3 Mounting Slots
4 Latch to open
battery compartment
5 Battery compartment
Install 9V battery here
6 Turn this way to remove
7 Turn this way to attach
FOLLOW THESE SIMPLE STEPS
2
3
7
6
1
4
5
1. Choose a location. See “Where to Install This
Alarm” for reference.
WARNING! Do not install this Alarm over an existing
electrical box. Only AC powered units are intended for
installation over electrical boxes.
2. Hold the bracket against the ceiling or wall and make a mark
inside each hole where you will drill your mounting hole. To
install on the wall, ensure that the round portions of the holes
are vertical. Put the Alarm where it won’t get covered with dust
while you drill the holes.
3. Use a 3/16" (5mm) drill bit to drill through the marks you made
for the mounting holes.
Mounting Hole Sets
4. Insert the plastic screw anchors (in the plastic bag with the screws) into the holes. Tap the screw
anchors gently with a hammer, if necessary, until they are ush with the ceiling or wall.
5. Insert the screws but do not tighten completely. Leave them about 1/8" (3mm) away from the wall.
6. Activate the battery. With the battery compartment
open, install the battery so the terminals on the battery
match the terminals on the Smoke Alarm. Match “+”
to “+” and “-” to “-.” Push the battery in until it snaps
in securely and cannot be shaken loose. If the battery
is not snapped in completely, the unit cannot receive
battery power. The Smoke Alarm may beep briey
when you install the battery—this is normal.
If battery pull tab exists, activate the battery back-up by removing the “Pull to Activate Battery
Back-Up” tab. You do no need to open the battery compartment during installation.
7. Position the base of the Smoke Alarm over the mounting bracket and turn. The Alarm can
be positioned over the bracket every 60°. Turn the Smoke Alarm clockwise (right) until the
unit is in place.
8. Test the Smoke Alarm. SeeWeekly Testing.”
Action What You Will See & Hear
Normal Operations Horn: Power LED: Silent; Flashes GREEN 1 time every
minute; OffSmoke LED:
When You Test the Alarm
Horn: Short “chirp”, then 3 beeps, pause, 3 beeps;
Power LED: Smoke LED: Flashes GREEN 1 time; Flashes
RED in sync with horn
If Battery Becomes Low Horn: Power LED: Chirps 1 time every minute; Flashes
Green 1 time every minute; OffSmoke LED:
Low Battery
Signal is Silenced
Horn: Power LED: Silent (for up to 8 hours); Flashes
Green 1 time every minute; OffSmoke LED:
Alarm is Not
Operating Properly
(Malfunction Signal)
Horn: Power LED: 3 chirps every minute; Flashes Green
3 times every minute; OffSmoke LED:
Alarm has
reached End of Life
Horn: Power LED: 5 chirps every minute; Flashes Green
5 times every minute; OffSmoke LED:
End of Life
Signal is Silenced
Horn: Power LED: Silent (for up to 2 days, 14 days total);
Flashes Green 5 times every minute; OffSmoke LED:
Smoke is Detected Horn: 3 beeps, pause, 3 beeps, repeat; Off; Power LED:
Smoke LED: Flashes Red in sync with horn
Smoke Alarm is Silenced
(up to 15 Minutes)
Horn: Power LED: Smoke LED: Off; Off; Flashes Red 3
times, pause, 3 times, repeat.
04 ALARM FEATURES
Add protection in minutes.Easy Installation:
LOCKING FEATURES
The optional locking features are designed to discourage unauthorized removal of the
battery or Alarm. It is not necessary to activate the locks in single-family households where
unauthorized battery or Alarm removal is not a concern.
These Smoke Alarms have two separate locking
features: one to lock the battery compartment, and the
other to lock the Smoke Alarm to the mounting bracket.
You can choose to use either feature independently,
or use them both.
Tools you will need: Needle-nose pliers or utility knife,
standard athead screwdriver
Both locking features use locking pins, which are molded into the mounting bracket. Using
needle nose pliers or a utility knife, remove one or both pins from the mounting bracket,
depending on how many locking features you want to use.
IMPORTANT!
To permanently remove the locking pin, insert a athead screwdriver between the
locking pin and the lock and pry the pin out of the lock.
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you have installed the battery and
tested the unit.
1. Push and release the Test/Silence button. The Alarm will “chirp” and then sound: 3 beeps,
pause, 3 beeps, pause.
IMPORTANT!
If the unit does not Alarm
during testing, DO NOT lock the
battery compartment! Install a
new battery and test again. If
the Alarm still does not Alarm,
replace it immediately.
2. Using needle-nose pliers or a utility
knife, detach one locking pin from
the mounting bracket.
3. Push the locking pin through the
black dot on the label on the back of
the Smoke Alarm.
TO UNLOCK THE BATTERY COMPARTMENT
1. Remove the Smoke Alarm from the mounting
bracket. If the unit is locked to the bracket, see the
section “To Unlock the Mounting Bracket.”
2. Insert a athead screwdriver under the head of
the locking pin, and gently pry it out of the battery
compartment lock. (If you plan to relock the battery
compartment, save the locking pin.)
3. To relock the battery compartment, close the battery
door and reinsert locking pin in lock.
4. Reattach the Smoke Alarm to the mounting bracket.
IMPORTANT!
When replacing the batteries, always test the Alarm before relocking the battery compartment.
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers,
detach one locking pin
from mounting bracket.
2. Insert the locking pin
into the lock located on
the pivoting hinge of the
battery compartment.
3. When you attach the
Smoke Alarm to the
mounting bracket,
the locking pin’s head
will t into a notch
on the bracket.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a athead screwdriver
between the mounting bracket
pin and the mounting bracket.
2. Pry the Alarm away from
the bracket by turning both
the screwdriver and the
Alarm counterclockwise (left)
at the same time.
05 TESTING & MAINTENANCE
WEEKLY TESTING
! WARNING!
use an open ame of any kind to test this unit. You might accidentally damage or set re to NEVER
the unit or to your home.
stand close to the Alarm when the horn is sounding. Exposure at close range may be DO NOT
harmful to your hearing. When testing, step away when horn starts sounding.
! CAUTION!
It is important to test this unit every week to make sure it is working properly. Using the Test/Silence
button is the recommended way to test this Smoke Alarm. Press and hold the Test/Silence button on
the cover of the unit until the Alarm sounds (the unit may continue to Alarm for a few seconds after
you release the button). If it does not Alarm, make sure the unit is receiving power and test it again.
If it still does not Alarm, replace it immediately. During testing you will hear a loud, repeating horn
pattern: 3 beeps, pause, 3 beeps, pause.
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but there are a few simple things
you must do to keep it working properly.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum the outside of the Smoke Alarm
using your household vacuums soft brush attachment. Test the Smoke Alarm. Never use water,
cleaners or solvents since they may damage the unit.
If the green power LED ashes 2 times every minute (horn is silent) it means that the Alarm needs
to be cleaned as indicated above. If green LED continues to ash, please call Consumer Support.
If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be
cleaned to avoid unwanted Alarms, replace the unit immediately.
Relocate the unit if it sounds frequent unwanted Alarms. See “Where This Alarm Should Not Be
Installed” for details.
When the battery becomes weak, the Smoke Alarm unit will “chirp” about once a minute (the
low battery warning). This low battery warning should last for 7 days, but you should replace the
battery immediately to continue your protection.
Protect or cover the alarm when doing any maintenance to home i.e. sanding oors, painting,
drywall patching, etc. to prevent contamination.
CHOOSING A REPLACEMENT BATTERY:
Your Smoke Alarm requires one standard 9V battery. The following batteries are acceptable as
replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522, Eveready (Energizer)
#1222. These batteries are available at many local retail stores.
! WARNING!
Always use the exact batteries specied by this User’s Manual. DO NOT use rechargeable
batteries. Clean the battery contacts and also those of the device prior to battery
installation. Install batteries correctly with regard to polarity (+ and -).
Please dispose of or recycle used batteries properly, following any local regulations.
Consult your local waste management authority or recycling organization to nd an
electronics recycling facility in your area. DO NOT DISPOSE OF BATTERIES IN FIRE.
BATTERIES MAY EXPLODE OR LEAK.
! WARNING!
Keep battery out of reach of children. In the event a battery is swallowed, immediately
contact your poison control center, your physician, or the National Battery Ingestion hotline
at 202-625-3333 as serious injury may occur.
IMPORTANT
Actual battery service life depends on the Alarm and the environment in which it is installed. All
the batteries specied above are acceptable replacement batteries for this unit. Regardless of the
manufacturers suggested battery life, you MUST replace the battery immediately once the unit starts
“chirping” (the “low battery warning”).
TROUBLESHOOTING GUIDE
IF THE ALARM... PROBLEM... YOU SHOULD...
Green Power light is off. Unit
will not Alarm when you
press the Test/Silence button
Battery may be
dead or missing. Replace battery*
Horn “chirps” and Green
Power LED ashes
1 time every minute
Battery is low Replace battery*
Horn “chirps” and Green
Power LED ashes
3 times every minute
MALFUNCTION SIGNAL.
Device is not working
properly, and needs
to be replaced.
If unit is under warranty,
contact Consumer
Support to process a
warranty replacement.
Horn “chirps” and Green
Power LED ashes
5 times every minute
END OF LIFE SIGNAL.
Alarm needs
to be replaced.
Replace Alarm immediately
Power LED ashes Green
2 times every minute Alarm requires cleaning
Clean Alarm then press and
release the test button. See
“Regular Maintenance”
section. If Green LED
continues to ash, contact
Consumer Support.
Alarm goes back into
Alarm after you press the
Test/Silence button to
silence the Alarm
Smoke levels are still
potentially dangerous
Refer to “If your Smoke
Alarm Sounds” for
details on how to
respond to an Alarm.
EVACUATE your home
immediately and call 911.
Smoke Alarm sounds when
no smoke is visible.
Unwanted Alarm may be
caused by nonemergency
source like cooking smoke.
Silence Alarm using Test/
Silence button. Clean the
Alarm’s cover with a soft,
clean cloth. If frequent
unwanted Alarms continue,
relocate your Alarm. Alarm
may be too close to a
kitchen, cooking appliance
or steamy bathroom.
*For a list of acceptable replacement batteries, see “Regular Maintenance.”
If you have questions that cannot be answered by reading this manual, call the
Consumer Support Team at 1-800-323-9005
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking materials properly. Never smoke in
bed. 2) Keep matches or lighters away from children; 3) Store ammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload electrical circuits; 5) Keep stoves,
barbecue grills, replaces and chimneys grease- and debris-free; 6) Never leave anything cooking on
the stove unattended; 7) Keep portable heaters and open ames, like candles, away from ammable
materials; 8) Don’t let rubbish accumulate. Keep Alarms clean, and test them weekly. Replace Alarms
immediately if they are not working properly. Smoke Alarms that do not work cannot alert you to a re.
Keep at least one working re extinguisher on every level, and an additional one in the kitchen. Have re
escape ladders or other reliable means of escape from an upper level in case stairs are blocked; 9) Have
an escape plan and practice it regularly.
06 IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an Alarm, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.
! WARNING!
If the unit Alarms get everyone out of the house immediately.
If the unit Alarms and you are not testing the unit, it is warning you of a potentially dangerous
situation that requires your immediate attention. NEVER ignore any Alarm. Ignoring the Alarm may
result in injury or death.
Never remove the batteries from a battery operated Smoke Alarm to stop an unwanted Alarm
(caused by cooking smoke, etc.). Removing batteries disables the Alarm so it cannot sense smoke,
and removes your protection. Instead open a window or fan the smoke away from the unit. The
Alarm will reset automatically.
WHAT TO DO IN CASE OF FIRE
Don’t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.
Feel doors with the back of your hand before opening them. If a door is cool, open it slowly. Don’t
open a hot door. Keep doors and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.
Meet at your planned meeting place outside your home, and do a head count to make sure
everybody got out safely.
Call the Fire Department as soon as possible from outside. Give your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
! WARNING!
Alarms have various limitations. See “General Limitations of Smoke Alarms” for details.
07 USING THE SILENCE FEATURES
The Silence Feature can temporarily quiet an unwanted Alarm for up to 15 minutes. To use this feature,
press the “Test/Silence” button. The Alarm remains functional. The LED will ash 3 times every few
seconds (for up to 15 minutes) to remind you the Alarm has been silenced. The ashing LED will stop
when the unit returns to normal operation..
! WARNING!
The Silence Feature does not disable the unit—it makes it temporarily less sensitive to smoke.
For your safety, if smoke around the unit is dense enough to suggest a potentially dangerous
situation, the unit will stay in Alarm or may re-Alarm quickly. If you do not know the source of
the smoke, do not assume it is an unwanted Alarm. Not responding to an Alarm can result in
property loss, injury, or death. If the unit will not silence and no heavy smoke is present, or if it
stays in silence mode continuously, it should be replaced immediately.
SILENCING THE LOW BATTERY WARNING
This Silence Feature can temporarily quiet the Low Battery Warning “chirp”. Press the Test/Silence
button on the Alarm. The Green light ashes normally, once every minute, during Low Battery Warning
silence. After time, the low battery “chirp” will resume. Replace the battery immediately.
SILENCING THE END OF LIFE SIGNAL
This Silence Feature can temporarily quiet the End of Life warning “chirp” for up to 2 days. You
can silence the End of Life warning “chirp” by pressing the Test/Silence button. The horn will chirp,
acknowledging that the End of Life Silence Feature has been activated.
After approximately 2 days, the End of Life “chirp” will resume. The timer shall not be able to be reset
after 14 days following the initial end-of-life signal.
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of a dead, missing or weak batteries, a build-up of
dirt, dust or grease on the Smoke Alarm cover, or installation in an improper location. Clean the Smoke
Alarm as described in “Regular Maintenance and install fresh batteries, then test the Smoke Alarm
again. If it fails to test properly when you use the test button, or if the problem persists, replace the
Smoke Alarm immediately.
If you hear 3 or 5 chirps every minute or so, replace the Smoke Alarm.
If you experience frequent non-emergency Alarms (like those caused by cooking smoke), try
relocating the Smoke Alarm.
If the Alarm sounds when no smoke is visible, try cleaning or relocating the Smoke Alarm. The
cover may be dirty.
Do not try xing the Alarm yourself — this will void your warranty!
If the Smoke Alarm is still not operating properly, and it is still under warranty, please see “How to
Obtain Warranty Service” in the Limited Warranty.
08 REGULATORY INFORMATION
FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
INSTALLING SMOKE ALARMS IN SINGLE-FAMILY RESIDENCES
The National Fire Protection Association (NFPA), recommends one Smoke Alarm on every oor, in every
sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC powered and
interconnected. See “Agency Placement Recommendations” for details. For additional coverage, it is
recommended that you install a Smoke Alarm in all rooms, halls, storage areas, nished attics, and
basements, where temperatures normally remain between 40˚ F (4.4˚ C) and 100˚ F (37.8˚ C). Make
sure no door or other obstruction could keep smoke from reaching the Smoke Alarms.
MORE SPECIFICALLY, INSTALL SMOKE ALARMS:
On every level of your home, including nished attics and basements.
Inside every bedroom, especially if people sleep with the door partly or completely closed.
In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each.
If a hall is more than 40 feet long (12 meters), install a unit at each end.
At the top of the rst-to-second oor stairway, and at the bottom of the basement stairway.
IMPORTANT!
Specic requirements for Smoke Alarm installation vary from state to state and from region to region.
Check with your local Fire Department for current requirements in your area. It is recommended AC
or AC/DC units be interconnected for added protection.
HARDWIREDBATTERY OPERATED & WIRELESS
MULTI-STORY RESIDENCE1-STORY RESIDENCE
Wireless Alarms
Wireless Interconnected Alarms
Hardwired Interconnected
AC or AC/DC Alarms
Smoke Alarms
CO Alarms
Both OR Combination
Smoke/CO Alarms
09 AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 CHAPTER 29 “FOR YOUR INFORMATION, THE NATIONAL FIRE ALARM AND SIGNALING
CODE, NFPA 72, READS AS FOLLOWS:”
29.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards for a specic type of
occupancy, approved single and multiple-station Smoke Alarms shall be installed as follows:
1. *In all sleeping rooms and guest rooms
2. *Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door to a
sleeping room, with the distance measured along a path of travel
3. On every level of a dwelling unit, including basements
4. On every level of a residential board and care occupancy (small facility), including basements and
excluding crawl spaces and unnished attics
5. *In the living area(s) of a guest suite
6. In the living area(s) of a residential board and care occupancy (small facility)
(Reprinted with permission from NFPA 72
®
, National Fire Alarm and Signaling Code Copyright © 2012
National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete
and ofcial position of the National Fire Protection Association, on the referenced subject which is
represented only by the standard in its entirety).
(National Fire Alarm and Signaling Code
®
and NFPA 72
®
are registered trademarks of the National Fire
Protection Association, Inc., Quincy, MA 02269).
10 SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm is suitable for use in apartments, condominiums, townhouses, hospitals, day care
facilities, health care facilities, boarding houses, group homes and dormitories provided a primary re
detection system already exists to meet re detection requirements in common areas like lobbies,
hallways, or porches. Using this Smoke Alarm in common areas may not provide sufcient warning to
all residents or meet local re protection ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete re detection systems in places
housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals,
health care facilities, nursing homes, day care facilities, or group homes of any kind. It is not a
suitable substitute for complete re detection systems in warehouses, industrial facilities, commercial
buildings, and special-purpose non-residential buildings which require special re detection and Alarm
systems. Depending on the building codes in your area, this Smoke Alarm may be used to provide
additional protection in these facilities.
In new construction, most building codes require the use of AC or AC/DC powered Smoke Alarms only.
In existing construction, AC, AC/DC, or DC powered Smoke Alarms can be used as specied by local
building codes. THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION’S STANDARD 72 (National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269). Refer to NFPA 101 (Life Safety Code), local building codes, or consult your Fire
Department for detailed re protection requirements in buildings not dened as “households”.
FCC COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that the interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that of the receiver.
Consult the dealer or an experienced radio or TV technician for help.
! WARNING!
Changes or modications to the product, not expressly approved by First Alert, could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
11 GENERAL LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in reducing deaths resulting from home res worldwide.
However, like any warning device, Smoke Alarms can only work if they are properly located, installed,
and maintained, and if smoke reaches them. They are not foolproof.
Smoke Alarms may not waken all individuals. Practice the escape plan at least twice a year,
making sure that everyone is involved – from kids to grandparents. Allow children to master re
escape planning and practice before holding a re drill at night when they are sleeping. If children
or others do not readily waken to the sound of the Smoke Alarm, or if there are infants or family
members with mobility limitations, make sure that someone is assigned to assist them in re drill and
in the event of an emergency. It is recommended that you hold a re drill while family members are
sleeping in order to determine their response to the sound of the Smoke Alarm while sleeping and to
determine whether they may need assistance in the event of an emergency.
Smoke Alarms cannot work without power. Battery operated units cannot work if the batteries
are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not
installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit
breaker, failure along a power line or at a power station, electrical re that burns the electrical wires,
etc.). If you are concerned about the limitations of battery or AC power, install both types of units.
Smoke Alarms cannot detect res if the smoke does not reach the Alarms. Smoke from res in
chimneys or walls, on roofs, or on the other side of closed doors may not reach the sensing chamber
and set off the Alarm. That is why one unit should be installed inside each bedroom or sleeping area—
especially if bedroom or sleeping area doors are closed at night—and in the hallway between them.
Smoke Alarms may not detect re on another level or area of the home. For example, a stand-
alone unit on the second level may not detect smoke from a basement re until the re spreads. This
may not give you enough time to escape safely. That is why recommended minimum protection is
at least one unit in every sleeping area, and every bedroom on every level of your home. Even with
a unit on every level, stand-alone units may not provide as much protection as interconnected units,
especially if the re starts in a remote area. Some safety experts recommend installing interconnected
AC powered units with battery back-up (see “About Smoke Alarms”) or professional re detection
systems, so if one unit senses smoke, all units Alarm. Interconnected units may provide earlier
warning than stand-alone units since all units Alarm when one detects smoke.
Smoke Alarms may not be heard. Though the Alarm horn in this unit meets or exceeds current
standards, it may not be heard if: 1) the unit is located outside a closed or partially closed door, 2)
residents recently consumed alcohol or drugs, 3) the Alarm is drowned out by noise from stereo,
TV, trafc, air conditioner or other appliances, 4) residents are hearing impaired or sound sleepers.
Special purpose units, like those with visual and audible Alarms, should be installed for hearing
impaired residents.
The Alarm may not have time to Alarm before the re itself causes damage, injury, or death,
since smoke from some res may not reach the unit immediately. Examples of this include
persons smoking in bed, children playing with matches, when a person’s clothing catches re
while cooking, res caused by violent explosions resulting from escaping gas, or incendiary
res where the re grows so rapidly that an occupants egress is blocked even with properly
located Smoke Alarms.
Smoke Alarms are not foolproof. Like any electronic device, Smoke Alarms are made of components
that can wear out or fail at any time. You must test the unit weekly to ensure your continued
protection. Smoke Alarms cannot prevent or extinguish res. They are not a substitute for property or
life insurance.
Smoke Alarms have a limited life. The unit should be replaced immediately if it is not operating
properly. You should always replace a Smoke Alarm after 10 years from date of purchase. Write the
purchase date on the space provided on back of unit.
12 LIMITED WARRANTY
First Alert
®
warrants that for a period of ten years from the date of purchase, this product will be free
from defects in material and workmanship. First Alert, at its option, will repair or replace this product
or any component of the product found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component. If the product is no longer
available, replacement may be made with a similar product of equal or greater value. This is your
exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is
not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty
performance. First Alert dealers, service centers, or retail stores selling First Alert products do not have
the right to alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following:
negligent use or misuse of the product, use on improper voltage or current, use contrary to the
operating instructions, disassembly, repair or alteration by anyone other than First Alert or an
authorized service center. Further, the warranty does not cover Acts of God, such as re, ood,
hurricanes and tornadoes or any batteries that are included with this unit.
First Alert shall not be liable for any incidental or consequential damages caused by the breach of any
express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty
of merchantability or tness for a particular purpose is limited in duration to the duration of the above
warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental
or consequential damages or limitations on how long an implied warranty lasts, so the above
limitations or exclusion may not apply to you. This warranty gives you specic legal rights, and you
may also have other rights that vary from state to state or province to province.
HOW TO OBTAIN WARRANTY SERVICE
Service: If service is required, do not return the product to your retailer. In order to obtain warranty
service, contact the Consumer Support Team at 1-800-323-9005. To assist us in serving you, please
have the model number and date of purchase available when calling.
Battery: First Alert makes no warranty, express or implied, written or oral, including that of
merchantability or tness for any particular purpose with respect to battery.
Disposal: Please follow local guidelines regarding the disposal or recycling of batteries
and/or electronics.
For your records, please record:
Date Purchased: ___________________________
Where Purchased: __________________________
Date Installed: __________/__________Month/Year
Replace Alarm 10 years after installation.
Please write the date in the space provided:_____________/____________ Month/Year
The Alarm will also provide an audible End-of-Life Signal approximately 10 years after
installation to remind you to replace the unit.
The End-of-Life Signal can be silenced for up to 2 days. Do not unplug or deactivate the Alarm
until you get replacement.
Printed in Mexico | M08-179721 01/23
CONFORMS TO UL STD 217
rstalert.com
K1 © 2023 Resideo Technologies, Inc. All rights reserved. These products are
manufactured by Resideo Technologies, Inc. and its afliates. 3901 Liberty Street,
Aurora, IL 60504-8122. Consumer Support Team: (800) 323-9005 | rstalert.com


Product specificaties

Merk: First Alert
Categorie: Rookmelder
Model: SMI100

Heb je hulp nodig?

Als je hulp nodig hebt met First Alert SMI100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder First Alert

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Kidde

Kidde CO120X Handleiding

2 December 2024
EQ-3

EQ-3 HM-Sec-SD-2 Handleiding

30 November 2024
EQ-3

EQ-3 HM-Sec-SD Handleiding

30 November 2024
EQ-3

EQ-3 HMIP-SWSD Handleiding

30 November 2024
Pentatech

Pentatech RA170Q Handleiding

24 November 2024
Cordes

Cordes CC-4100 Handleiding

18 November 2024
Cordes

Cordes CC-3000 Handleiding

18 November 2024
Cordes

Cordes CC-500 Handleiding

18 November 2024
Nexa

Nexa KD-134A Handleiding

18 November 2024
Gloria

Gloria R-5 Handleiding

16 November 2024