Hochiki HCA-4 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Hochiki HCA-4 (56 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/56
HCA Series
Conventional Fire Alarm System
(HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D)
Installation and Operation Manual
Hochiki America Corporation
7051 Village Drive, Suite 100
Buena Park, CA90621-2268
714.522.2246 Corporate Headquarters
800.845.6692 Technical Support
http://www.hochiki.com
Version 2.09
Created: 12/18/2012
HA-06-266
HCA Series Installation Manual Page 2 of 56 V2.09
Table Contentsof 
1.Introduction ..................................................................................................................... 5
1.1

Product Features .............................................................................................................. 5

1.2

Electrical Specifications ..................................................................................................... 6

1.3

Fire Alarm System Limitations............................................................................................ 7

1.4

Installation Precautions ..................................................................................................... 8

2.Controls and Indicators .................................................................................................. 10
2.1

Front Panel User Control Buttons ..................................................................................... 10

2.2

LED Indicators: .............................................................................................................. 10

2.3

Local Piezoelectric (PZT) Sounder: ................................................................................... 11

3.Control Panel Installation ................................................................................................ 12
3.1

Agency Requirements ..................................................................................................... 12

3.2

Requirements for All Installations..................................................................................... 12

3.3

Calculating Current Draw and Battery Size ........................................................................ 13

3.3.1Maximum Battery Standby Load ........................................................................................... 13
3.3.2Calculating Maximum Current Draw & Battery Backup Requirements ................................. 13
3.4

Mounting the Enclosure .................................................................................................. 15

3.5

AC Power Connection ..................................................................................................... 15

3.6

Battery Installation ......................................................................................................... 16

3.7

NAC Output Circuit Installation ........................................................................................ 17

3.8

Zone Installation ............................................................................................................ 18

3.9

Inner Door Label (Wiring Diagram) .................................................................................. 19

3.10

Relay Outputs ................................................................................................................ 20

3.11

DACT Phone Lines .......................................................................................................... 21

3.12

Remote Annunciator (Model HCA-RA) ............................................................................... 22

3.12.1HCA-RA Installation .......................................................................................................... 22
3.12.2HCA-RA Specifications ..................................................................................................... 23
3.13
Diagnostic LEDs ............................................................................................................. 24

4.Control Panel Operations ................................................................................................ 25
4.1

LCD Display Screens ....................................................................................................... 25

4.1.1Initial Display Screen after System Initialization and Panel Revision ................................... 25
4.1.2System Normal Status Screen .............................................................................................. 26
4.1.3Off Normal System Status Screens and Sounds .................................................................. 26
4.1.4Zone Alarm and/or Trouble Screens ..................................................................................... 26
4.1.5System TROUBLE Screens .................................................................................................. 26
4.1.6NAC Output Trouble Screens ................................................................................................ 27
4.1.7Multiple Trouble Screens ....................................................................................................... 27
4.1.8Active Alarms and Trouble Screens ...................................................................................... 27
4.2

Operation Keys .............................................................................................................. 28

HCA Series Installation Manual Page 3 of 56 V2.09
4.2.1System Reset ........................................................................................................................ 28
4.2.2System Silence ...................................................................................................................... 28
4.2.3System Acknowledge ............................................................................................................ 28
4.3

Login Screen .................................................................................................................. 28

4.3.1Default Access Codes ........................................................................................................... 28
4.4

User Top Level Menu Options .......................................................................................... 28

4.5

Installer Top Level Menu Options ..................................................................................... 29

4.6

Fire Drill ........................................................................................................................ 30

4.7

Date/Time Setup ............................................................................................................ 30

4.8

Walk Test ...................................................................................................................... 31

4.9

Event History ................................................................................................................. 31

4.9.1Viewing Event History ........................................................................................................... 31
4.9.2Clearing Event History ........................................................................................................... 32
4.10

Disabling Circuits ............................................................................................................ 32

4.10.1Disabling or Enabling Zones ............................................................................................. 32
4.10.2Disabling or Enabling Outputs .......................................................................................... 33
4.11

Manual DACT test .......................................................................................................... 33

4.12

Operating the Remote Annunciator .................................................................................. 33

5.Programming ................................................................................................................. 34
5.1

Editing User and Installer Access Codes ........................................................................... 34

5.2

Zone Programming Options ............................................................................................. 34

5.2.1Zone Edit ............................................................................................................................... 34
5.2.2Shorted Zone Mode ............................................................................................................... 35
5.3

Output Circuits and Relay Programming ........................................................................... 36

5.3.1Reserved ............................................................................................................................... 36
5.3.2NAC Output circuits ............................................................................................................... 36
5.3.3Relay Silencing Programming ............................................................................................... 38
5.3.4Cadence Pattern Programming ............................................................................................. 38
5.4

Releasing Programming Options ...................................................................................... 39

5.4.1Agent Releasing .................................................................................................................... 39
5.4.2Water Releasing .................................................................................................................... 42
5.4.3How to Install the Disconnect Switch on the Releasing Circuit ............................................. 45
5.5

Remote Annunciator ....................................................................................................... 47

5.6

DACT Setup ................................................................................................................... 47

5.6.1Enable/Disable the DACT ..................................................................................................... 47
5.6.2Auto Test Time of Day ........................................................................................................... 47
5.6.3Low AC Reporting Delay ....................................................................................................... 48
5.6.4Edit Accounts ......................................................................................................................... 48
5.6.5Edit Phone Lines ................................................................................................................... 51
5.7

Panel Factory Default Setup ............................................................................................ 52

5.7.1Factory Default Settings ........................................................................................................ 52
6.DACT Reporting Codes and Compatible Receivers ............................................................ 53
6.1

DACT Reporting Codes for SIA and Contact ID .................................................................. 53



Product specificaties

Merk: Hochiki
Categorie: Rookmelder
Model: HCA-4
Ingebouwd display: Ja
Type stroombron: AC, DC
Tekstregels: 2 regels
Koolmonoxidemelder: Nee
AC-ingangsspanning: 120 V
AC-ingangsfrequentie: 50 - 60 Hz
Type beeldscherm: LCD
Bedrijfstemperatuur centrale besturingseenheid (T-T): 0 - 49 °C
Brandmeldcentrale: Ja
Rookmelders: Nee
Number of devices supported: 8
Relay uitgangen: 5
Centrale besturingseenheid werkzaam bij relatieve vochtigheid (V-V): 0 - 95 procent
Afmetingen centrale besturingseenheid (BxDxH): 370 x 112 x 393 mm
Certificering centrale besturingseenheid: UL864, NFPA
Accuspanning centrale besturingseenheid: 12 V
Hittedetector: Nee
Geluidsalarmeenheid voor noodgevallen: Nee
Kleur van centrale besturingseenheid: Rood
Gewicht centrale besturingseenheid: 6400 g
Accustroomsterkte centrale besturingseenheid: 6.5 A

Heb je hulp nodig?

Als je hulp nodig hebt met Hochiki HCA-4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder Hochiki

Hochiki

Hochiki HCA-4 Handleiding

25 Februari 2025
Hochiki

Hochiki ACC-V Handleiding

25 Februari 2025
Hochiki

Hochiki ALN-V Handleiding

25 Februari 2025
Hochiki

Hochiki SOC-24V Handleiding

25 Februari 2025

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder