Model name: FMR 4337
EN 14604:2005/AC:2008
1772-CPR-140162
1772-Q-140162
DoP-Nr.: DK00493900
Typ: FMR 004337
www.gev.de
04337
> 50 cm
> 50 cm
> 50 cm
≤ 7,5 m
≤ 15 m
1/4 1/4
1/4 1/4
0,5
-
1
m
> 20°
EB
C
D D1
A G
F
2
1
3
ø
3,5 mm
1
ø
3,5 mm
3
0,5
-
1
m
> 20° > 20°
1/2 1/2
4 5
Montageort
Um eine optimale Absicherung von Haushalten zu erreichen, sollten
Rauchwarnmelder in allen Räumen, Fluren, Keller- und Vorratsräumen
installiert werden. Eine Grundabsicherung wird schon durch den
Einsatz von Rauchwarnmeldern in allen Schlafräumen, Kinderzimmern
und auf den Fluren sämtlicher Etagen erreicht (Abb. A).
Hinweis:
• MeldermittiganderDeckemontieren.
• In Badezimmern (hohe Luftfeuchtigkeit), Garagen
(Abgase),instarkzugluftgefährdeterUmgebung(auchz.B.
Lüftungsauslass Lüftungseinlass)undinSpitzecken aufdem
Dachboden sollten Rauchwarnmelder nicht installiert werden (Abb. D).
•BeieinerDachneigung  20°kann der Meldermittigwiebei
horizontalenDeckenmontiertwerden.
•BeieinerDachneigung>20°mussderMeldermindestens0,5mund
max.1mvonderDeckenspitzeentferntmontierenwerden(Abb. D).
•Wenn dieanteiligen Dachschgeneinen Dachwinkel> 20°
habenunddiehorizontaleDecke1 m breit ist, dann sollte der
Meldermind.0,5mundmax.1mvonderDeckenspitzeander
Dachschräge montiert werden . Sollte aber die horizontale (Abb. D)
Deckebreiterals1msein,dannkannderMeldermittiganderDecke
montiert werden .(Abb. D1)
BittehaltenSiemindestens50cmAbstandvonWänden,Deckenbalken
(Unterzügen),EinrichtungsgegenständenundLeuchten(Abb. B C).
SindDeckenbalken(Unterzüge)vorhanden,giltfolgendes:
Höhe≤20cm:Deckenfelderbleibenunberücksichtigt.Melderdarf
auchaufdemDeckenbalken(Unterzug)montiertwerden.
Höhe>20cmundDeckenfeld>36:JeDeckenfeld>1Melder
montieren.
he>20cmundDeckenfeld36m²:Deckenfelder bleiben
unberücksichtigt.MelderdarfauchaufdemDeckenbalken(Unterzug)
montiert werden.
Mit dem Kauf dieses Artikels haben Sie sich für ein qualitativ
hochwertiges GEV Produkt entschieden. Bitte lesen
Sie diese Bedienungsanleitung sorgfältig durch, um ein
einwandfreies Funktionieren zu gehrleisten. Bewahren
Sie diese Anleitung sorgfältig auf, um gegebenenfalls
später nachlesen zu können. Das Produkt ist nur für den
sachgemäßen Gebrauch (wie in der Bedienungsanleitung
beschrieben) bestimmt. Änderungen, Modifikationen oder
Lackierungen dürfen nicht vorgenommen werden, da sonst
jeglicher Gewährleistungsanspruch entllt.
DerFMR4337isteinfotoelektronischerRauchwarnmelder zur
frühzeitigenundzuverlässigenBranderkennunginpr ivaten
Wohnhäusern,Wohnungenundumenmitwohnungsähnlicher
NutzungzurErllungdergesetzlichenRauchwarnmelderpicht.
Nachtsbrenntes amhäugsten. ImSchlafistderGeruchssinn
beiMenschennichtaktivundRauchkannnichtwahrgenommen
werden.DahersctzteinRauchwarnmelderwirksamundfrühzeitig
vor der drohenden Gefahr. Alarm wird ausgelöst sobald Rauch in
dasInnere desGeteseindringt.FlammenwerdenvomGet
nicht wahrgenommen.
UmdieWartungs-undBetriebskostenniedrigzuhalten,wurde der
FMR4337miteinerfesteingebautenLithium-Batteriefüreineextreme
Langlebigkeitvon10Jahrenausgelegt.EinBatterietauschistnicht
erforderlich.NachAblaufderBatterielebensdauervon10Jahren
wird der FMR 4337 einfach ausgetauscht. Eine Alarmabschaltung
rca.8-9Min.erfolgtdurcheinenkurzenDruckaufdieTaste
(Abb. G3). Dabei wird der FMR 4337 in einen weniger empndlichen
ZustandversetztundzeigtdiesdurchBlinkenderrotenLEDca.
alle10Sek.an.IstdieRauchdichtezugr,wirdderAlarmerneut
ausgelöst.Achtung!DerMelderdarfnichtübermäßiggroßerHitze
ausgesetzt werden, um e ine gliche Gefährdung durch die
Batteriezuvermeiden.
Fotoelektronischer Rauchwarnmelder FMR 4337
•Räumeüber60m²undFlurelängerals15mbenötigenmehrere
Melder (Abb. A).
•BittehaltenSieeinemaximaleEinbauhöhevon6mein.Beihöheren
DeckenempfehlenwirmehrereMelderinverschiedenenEbenen
zu montieren.
•WirdeinRaumdurcheinPodestodereineGalerieinderHöhe
unterteilt, so ist unterhalb dieser Einrichtungen dann ein Melder
erforderlich,wennsowohlderenFläche16m²als auchderen
LängeundBreitejeweils2mübersteigen.
•BittehaltenSiemindestens4mAbstandvonoenenKaminen,
Herden, etc. ein.
•Setzensie denMelder keinerstarken Lichtquelleaus, wie
zumBeispielSonnenstrahlen.DerMelderquittiertdiesdurch
3 Pieptöne alle 40 s.
Montage/Inbetriebnahme
•PassensiedieArtderBefestigungdemMontageuntergrundan,
um Verletzungen zu vermeiden.
•Montieren Sie zuerst den Sockel möglichst mittig an der
 Decke(Abb. E).
•SchützenSiedieGerätevorBohrstaub.
•SetzenSie denMelderauf den Sockelunddrehen ihn im
Uhrzeigersinn bis er einrastet .(Abb. G1)
•DerRauchwarnmelderwirdübereinenReed-Kontaktdurch
einenMagnetenimSockel(Abb. F1) automatisch eingeschaltet,
sobaldderMeldersichinderkorrektenPositiondemSockel
nähert (Abb. G1).DieroteLEDblinktinAbständenvonca.5Min.
kurzauf undderMeldergibt3kurzeunterschiedliche(Abb. G2)
Pieptöne aus.
•FührenSiedieTestfunktionaus,indemSiedieTaste(Abb. G3) so
langegedrückthalten,biseinlauterundpulsierenderAlarmtonertönt
(siehe auch Test / Wartung).BeitechnischenProblemenwenden
SiesichbitteandenHerstelleroderDistributorinIhremLand.
DurchAbnehmendesMeldersvomSockelwirdderRauchwarnmelder
nachwenigenSekundenausgeschaltet.
Bedienung
Die Taste (Abb. G3)hatzweiFunktionen:
•StummschaltungdesAlarmsignalsfürca.10±1Min.durch
kurzenTastendruckbei Alarmauslösung oder vorbeugend,
umeinenAlarmzuverhindern.Währenddieser10±1Min.
blinktdieroteLED ca.alle10Sek.IstdieRauchdichte(Abb. G2)
zugroß,wirdderAlarmerneutausgelöst.
•TestfunktiondesMeldersdurchTastendruckbiseinlauterund
pulsierender Alarmton ertönt.
Reset erfolgt durch AbnehmendesMeldersvomSockelfür30Sek.
Test / Wartung
Bei der Test funktion wird der Melde r komplett ge mäß EN
14604geprüft:FunktionsprüfungderBatterie,elektronischer
Rauchkammertest,PfungderElektronik,etc.EinTestsollte
mindestens1xhrlichdurchgeführtwerden.DrückenSiedazudie
Taste (Abb. G3) solange, bis ein lauter und pulsierender Alarmton
ertönt(ca.85dB/3m).DasGerätsolltebeiBedarfetwa1xhrlich
trockenabgewischtundvonaußenmiteinemStaubsaugervorsichtig
abgesaugt werden. Achten Sie auf Einrichtungsgegenstände im
Umkreisvon0,5m,diedenRaucheintritteventuellbehindern
nnen.Indiesem FallmussderMontageortüberprüftund
gegebenenfalls neu festgelegt werden oder die entsprechenden
Einrichtungsgegenständemüssenentferntwerden.
DerMelderhrtpermanenteinenautomatischenSelbsttestdurch.
HierbeiwerdenunteranderemdieElektronik,dieSpannungund
derInnenwiderstandderBatterie,dieRauchkammerfunktion,etc.
überpft.DieordnungsgemäßeFunktionundBetriebsbereitschaft
wirdmiteinemkurzenBlinkzeichenderrotenLED(Abb. G2) ca.
alle 5 Min. signalisiert.
DenRauchwarnmelderbeieinermechanischenBeschädigung
oderimFalleeiner nichtrücksetzbarenSrungsmeldung,
spätestensjedoch10JahrenachInbetriebnahme,austauschen.
EinBatteriewechselistnichtmöglich.
DEGBFRITPL
6 7
Funktionstabelle
Alarmton Rote LED Erläuterung Abhilfe
Pulsierender
Alarmton.
Blitztca.2xproSek.
Alarmauslösung des Melders bei
Rauchdetektion.
StummschaltungdesAlarmsignalsfür10±1Min.durchkurzen
Tastendruck.
Kein Ton Blitztca.alle10Sek.
Alarm-Stummschaltungfür10±1
Min.istaktiviert.
StummschaltungkannaufgehobenwerdendurchAbnehmen
desMeldersvomSockelfür30Sek.oderdurchdieTestfunktion:
LangerTastendruck(min.3Sek.)biseinlauterundpulsierender
Alarmton ertönt.
3kurzePieptöneca.
alle40Sek. Blitztca.alle5Min. Fehlfunktion.
StörungssignalkannaufgehobenwerdendurchAbnehmendes
MeldersvomSockelfür10Sek.KommtdieStörungdanach
wieder, muss der Melder ausgetauscht werden.
Kurzer Piepton ca.
alle40Sek. Blitztca.alle5Min.
Störungssignal des Melders bei einer
leerenBatterie.
StörungssignalkannaufgehobenwerdendurchAbnehmendes
MeldersvomSockelfür30Sek.
Kommt die Störung danach
wieder, muss der Melder ausgetauscht werden.
Kein Ton.
Blitztca.alle5Min.
Betriebsbereitschaft/Normalmodus/
Melder arbeitet fehlerfrei und ist bereit
zurRauchdetektion.
VorbeugendeStummschaltungdesAlarmsignalsfür10±1Min.
durchkurzenTastendruck.
Technische Daten
Typbezeichnung FMR 4337
Batteriebetrieb 3VoltLithiumCR14505festeingebaut
Batterielebensdauer 10JahrebeibestimmungsgemäßemGebrauch
Signallautstärke 85dB/3m
RelativeLuftfeuchtigkeit 10%–93%nichtkondensierend
Arbeitstemperaturbereich 0 °C bis +55 °C
Zulassung EN 14604:2005/AC:2008
CPR-Nummer 1772-CPR-140162
Q-Nummer 1772-Q-140162
DoP-Nr. DK00493900
Abmessungen Ø 83 mm, Höhe 47 mm
TechnischeundoptischeÄnderungenohneAnkündigungvorbehalten.
Hinweis:
SolltederMeldereinerzugroßenStaubmengeoderz.B.
Wasserdampf ausgesetzt werden, kann dies zu einer
Alarmauslösungführen.
Batterie- und Akkuhinweise
DiesesGerätenthälteinefesteingebauteLithium-Batterievom
TypCR14505.Altbatteriendürfennichtmitdemunsortierten
Siedlungsabfallentsorgtwerden.BesitzervonAltbatterien sind
gesetzlichzurckgabeverpichtetundkönnendieseunentgeltlich
beidenVerkaufsstellenzurückgeben.Batterienenthaltenumwelt-
undgesundheitsschädlicheStoeund müssendaherfachgerecht
entsorgt werden.
Recycling-Hinweise
Dieses Gerät darf nicht mit dem unsortierten Siedlungsabfall
entsorgtwerden.Besitzervon Altgerätensindgesetzlichdazu
verpichtet, dieses Gerät fachgerecht zu entsorgen.
InformationenerhaltenSievonIhrerStadt-bzw.Gemeindeverwaltung.
!
Richtiges Verhalten im Brandfall
Ruhe bewahren!
Alarmieren Sie die Feuerwehr.
FolgendeHinweisesindfürdieFeuerwehrwichtig:
•WieistIhrName?(Name,Telefonnummer)
•Wobrenntes?(Adresse)
•Wasistpassiert?(Ausmaß)
•WievieleVerletztegibtes?
•WartenSieaufRückfragendesGesprächspartners.
 WarnenSiealleMitbewohner.
 HelfenSieälteren,krankenundbehindertenPersonen.
 SchließenSiealleFensterundTüren.
 BenutzenSiekeinenAufzug.SolltenSieZweifel haben,obes
sich um einen echten Alarm oder um einen Fehlalarm handelt,
 verhaltenSiesichso,alsobeswirklichbrennt.
DEGBFRITPL
8 9
DEGBFRITPL
Note: • Mountthesmokedetector inthecentreoftheceiling
• Smokedetectorsmustnotbeinstalledinbathrooms(high
levelsofhumidity),garages(exhaustgases),environments
  withstrongdraughts(alsobye.g.aventilationairoutlet
orventilationairinlet)orincornersofattics(Fig. D)
• Onroofswithaslopeof 20°,thesmokedetectorcanbemounted
in the centre of the ceiling in the same way as for horizontal ceilings
• Forroofswithaslopeof>20°,thesmokedetectormust be
mounted at least 0.5 m and a maximum of 1 m away from the
peakoftheceiling(Fig. D)
• If theslopingsectionsofthe roofhave aroofangleof>20°
and the horizontal ceiling is 1m wide, the smokedetector
must be mounted on the slanted section at a minimum of
0.5mandamaximumof1mawayfromthepeakoftheceiling
(Fig. D). However, if the horizontal ceiling is wider than 1 m,
thesmokedetectorcanbemountedinthecentreoftheceiling
(Fig. D1)
• Pleasemaintainadistanceofatleast50cmfromwalls,ceiling
beams(joists),ttingsandlights(Fig. B – C)
Ifceilingbeams(joists)arepresent,thefollowingrequirementsapply:
Height20cm:Ceilingpanelsnottakenintoconsideration.Detector
canalsobettedontheceilingbeam(joist).
Height>20cmandceilingpanelarea>36m²:Fit
>
one detector
per ceiling panel
Height>20cmandceilingpanelarea≤36m²:Ceilingpanelsnot
takenintoconsideration.Detectorcanalsobettedontheceiling
beam(joist).
• Roomsofover 60m²andcorridorslongerthan15mrequire
severalsmokedetectors(Fig. A)
• Pleaseensurethatsmokedetectorsareinstalledataheightof6
m.Forhigherceilings,werecommendinstallingseveralsmoke
detectors at various levels
 Iftheheightofaroomisdividedbyalandingorabalcony,a
By purchasing this device you have chosen for a high-quality
GEV product. Please read through these operating instructions
carefully in order to ensure that the device functions correctly.
Keep these instructions in a safe place so that you can refer to them
later if necessary. Use this product only as intended (as
described in the user instructions). Do not alter, modify or paint
the device, as t his will render any warranties null and void.
TheFMR4337isaphotoelectronicsmokedetectorusedforearly
and reliable fire detection in private residential buildings, apartments
and rooms with similar purposes in compliance with the statutory
obligationtoinstallsmokedetectors.
Firesoccurmostfrequentlyatnight.Thehumansenseofsmellis
notactiveduringsleepmakingitimpossibletodetectsmoke.Smoke
detectorsthereforeactasaneectiveandpromptsafeguardagainst
imminentdanger.Analarmistriggeredassoonassmokeenters
thedevice.Thedevicedoesnotdetectames.
Tokeepmaintenanceandoperatingcostslow,theFMR4337was
designed with an integrated lithium battery to enable an extremely
long service life of ten years. There is no need to change the battery.
Oncetheten-yearbatterylifehasexpired,theFMR4337issimply
replaced.Thealarmcanbeswitchedoforapprox.89minutes
bybrieypressingthebutton(Fig. G3). This action switches the
FMR 4337 to a less sensitive status. This status is indicated by
theredLEDashingapprox.everytenseconds.Ifthesmokeis
too dense, the alarm is triggered again. Please note! To prevent
thebatteryfromposingahazard,thesmokedetectormustnot
be exposed to excessive heat.
Installation position
Foroptimumprotectionofyourhome,installsmokedetectorsinall
rooms,corridors,basementsandstorerooms.Basicprotectioncan
beachievedbyinstallingsmokedetectorsinallbedrooms,playrooms
andinthecorridorsonalloors(Fig. A).
FMR 4337 photoelectric smoke detector
smokedetectormustbeinstalledunderneaththesefacilitiesif
theycoveranareaofover16m²andhavealengthandwidth
greater than 2 m
• Pleaseinstallsmokedetectorsataminimumof4mawayfrom
open fireplaces, stoves, etc.
• Ensurethatthesmokedetectorisnotexposedtopowerfullight
sources,e.g.sunlight.Thesensoracknowledgesstronglightby
emitting three beeps every 40 seconds
Installation/Commissioning
•Topreventinjuries,ensurethatthetypeoffasteningissuitable
for the mounting surface
•Mountthebaseofthesmokedetectorontheceilingascentrally
as possible (Fig. E)
•Protectthedevicefromdustwhendrillingholes
•Mountthesmokedetectoronitsbaseandturnitinaclockwise
directionuntilitclicksintoplace(Fig. G1)
•Thesmokedetectorisswitchedonautomaticallyviaareedswitch
by a magnet in the base (Fig. F1)assoonasthesmokedetector
approaches the correct position in the base The red (Abb. G1).
LEDashesbrieyatve-minuteintervals( andthesmokeFig. G2)
detector emits three short varying beeps
•Executethetestfunctionbypressingandholdingthebutton
(Fig. G3) (see also Test/ until a loud, pulsating alarm signal sounds
Maintenance).Intheeventofanytechnicalproblems,contact
the manufacturer or your local distributor
•Removingthesmokedetectorfromthebasecausesthesmoke
detectortoswitchoafterafewseconds
Operation
The button has two functions:(Fig. G3)
•Temporarilysilencingthealarmforapprox.10±1minutesbybriey
pressing the button when the alarm is triggered or preventatively
tostopanalarmfromsounding.Duringthese10±1minutes,the
redLEDashes approx.every10seconds.Ifthesmoke(Fig. G2)
is too dense, the alarm is triggered again
•Testthefunctionofthesmokedetectorbypressingthebutton
until a loud, pulsating alarm sounds.
Thesmokedetectorcanberesetbyremovingitfromthebasefor
30 seconds.
Test/Maintenance
Whenthetestfunctionisselected,acompletetestofthesmoke
detector is performed in accordance with EN 14604, which includes
abatteryfunctiontest,electronicsmokechambertest,electronics
test, etc. A test must be performed at least once every year. To
testthesmokedetector,pressthebutton(Fig. G3) until a loud,
pulsatingalarmsignalsounds(approx.85dB/3m).Whennecessary
(aroundonceayear),wipethedevicewithaclean,dryclothand
carefullycleantheoutsidewithavacuumcleaner.Takenoteof
anyttingswithinaradiusof0.5mthatmaypreventsmokefrom
enteringthesmokedetector.Ifsuchttingsarepresent,the
mounting location must be reviewed and changed if necessary
or the fittings must be removed.
Thesmokedetectorcontinuouslyperformsautomaticself-testing
processes.Thisincludestestingtheelectronics,checkingthe
voltage and internal resistance of the battery, and testing the
smokechamberfunction,etc.Correctfunctionalityandoperational
readinessisindicatedbyabriefashingsignalfromtheredLED
(Fig. G2) approx. every 5 minutes.
Intheeventofmechanicaldamageorafaultmessagethatcannot
bereset,replacethesmokedetector.Thesmokedetector
must be replaced no later than 10 years after commissioning.
The battery cannot be changed.
Note: Ifthesmokedetectorisexposedtoexcessivequantities
of dust or steam, the alarm may be triggered.
10 11
Notes regarding batteries and battery packs
This device contains an integrated lithium type CR 14505 battery.
Used batteries must not be disposed of as unsorted household
waste. Used batteries must be recycled and may be returned free-of-
chargetotheplaceofsale.Batteriescontainsubstanceswhichare
harmful to the environment and to human health and must therefore
be disposed of correctly.
Recycling-Note
This device must not be disposed of as unsorted household
waste. Used devices must be disposed of correctly. Contact
your local town council for more information.
!
Correct action in the event of a fire
Keep calm!
Alert the fire service.
Itisimportantthatthereserviceistoldthefollowinginformation:
•Yourname(name,phonenumber)
•Thelocationofthere(address)
•Whathashappened(extentofre)
•Howmanypeopleareinjured
•Thenwaittoseeiftheoperatorhasanyquestions
Alert all the people who live with you.
 Helpaged,sickanddisabledpersons.
Close all windows and doors.
Do not use lifts. If you have any doubts as to whether
or not it is a genuine alarm or a fault, still act as if there is a real fire.
Table of functions
Alarm signal Red LED Description Solution
Pulsating alarm
signal
Flashes approx. twice per second
Alarmistriggeredwhensmokeis
detected
Temporarilysilencethe alarm for10±1minutes bybriey
pressing the button.
No signal
Flashes approx. every 10 seconds
Temporary silencing of the alarm is
activatedfor10±1min
Temporary silencing of the alarm can be cancelled by removing
thesmokedetectorfromthebasefor30secondsorinitiating
thetestfunction:Pressandholdthebutton(min.3seconds)
until a loud, pulsating alarm signal sounds.
Three short beeps
are emitted approx.
every 40 seconds
Flashes approx. every 5 minutes
Malfunction
Thefaultsignalcanbecancelledbyremovingthesmokedetector
fromthebasefor10seconds.Ifthefaultoccursagain,thesmoke
detector must be replaced.
Short signal emitted
approx. every 40
seconds
Flashes approx. every 5 minutes
Fault signalemitted bythesmoke
detector when battery is discharged
Thefaultsignalcanbecancelledbyremovingthesmokedetector
from the base for 30 seconds.
Ifthefaultoccursagain,thesmoke
detector must be replaced.
No signal
Flashes approx. every 5 minutes
Ready for operation/normal mode/
smokedetectorisworkingcorrectly
andisreadyforsmokedetection
Brieypress the button to temporarily silence the alarm
preventativelyfor10±1minutes.
Technical data
Model name FMR 4337
Battery Integrated3-voltlithiumCR14505battery
Batterylife  10yearswhenusedasintended
Alarmvolume  approx.85dB/3m
Relativehumidity  10%–93%non-condensing
Operatingtemperaturerange 0°Cto+55°C
Approval EN 14604:2005/AC:2008
CPR number 1772-CPR-140162
Q number 1772-Q-140162
DoP number DK00493900
Dimensions Ø 83 mm, height 47 mm
Technicalanddesignfeaturesmaybesubjecttochange.
DEGBFRITPL


Product specificaties

Merk: GEV
Categorie: Rookmelder
Model: FMR 4337
Kleur van het product: Wit
Hoogte: 47 mm
Stroombron: Batterij/Accu
Montagewijze: Inbouw
Diameter: 83 mm
Accu/Batterij voltage: 3 V
Levensduur batterij/accu: 10 jaar
Detector type: Foto-electrische reflectie detector
Licht alarm: Ja
Bedrijfstemperatuur (T-T): 0 - 50 °C
Batterijtechnologie: Lithium
Test knop: Ja
Alarm decibels: 85 dB