YOUR ULTIMATE ALLY IN POWER
PFC SINEWAVE UPS SERIES
CST1500S
USER MANUAL
1
7
6
2
3
4
5
8
14
15
10
15
12
11
13
9
FEATURES
1.
Power Switch
2. Power On Indicator
3. LCD Module Display
4. Display Switch
5. Silence Alarm Switch
6. Control Switch
7. USB Charging Ports
8. Battery and Surge Protected Outlets
9.
Full-Time Surge Protection Outlets
10. Circuit Breaker
11. Serial / USB Ports to PC
12. Communication Protection Ports (RJ45)
13. Wiring Fault Indicator (red)
14. Coax / Cable / DSS Surge Protection
15. Widely-Spaced Outlets Designed
for AC Adapters
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed
power protection, operation, and performance during the lifetime of the product. Please take a
few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product
loss or theft, and entitles you to free technical support. Register your product now to receive the
benefits of CyberPower ownership.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature and
humidity controlled indoor area free of
conductive contaminants. (Please see
specifications for acceptable temperature
and humidity range.)
CAUTION! To reduce the risk of electric shock,
do not remove the cover except to service the
battery. Turn o and unplug the unit before
servicing the batteries. There are no user ser-
viceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC
input power is disconnected.
CAUTION! The UPS must be connected to an
AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is
not grounded. If you need to de-energize this
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the
unit and unplug it from the AC power source
before connecting equipment to the unit.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit over current protec-
tion in accordance with the National Electric
Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
defined in the Standard for the Protection of
Electronic Computer/Data Processing Equip-
ment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a fire.
The batteries may explode.
CAUTION! Do not open or mutilate batteries.
Released electrolyte is harmful to the skin and
eyes. It may be toxic.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products
for life support or medical applications. DO
NOT use in any circumstance that would aect
operation and safety of life support equip-
ment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do
not use with or near an aquarium. Condensa-
tion from the aquarium can cause the unit to
short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do
not use the unit on any transportation such
as airplanes or ships. The eect of shock or
vibration caused during transit and the damp
environment can cause the unit to short out.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) Coaxial Cable
(d) USB A+B Type cable
(e) Function Setup Guide
PowerPanel® software is available on our
website. Please visit www.cyberpowersystems.
com and go to the Software Section for a free
download.
SUPPORTS ACTIVE PFC POWER SUPPLIES
This CyberPower UPS system supports High
Eciency power supplies with Active Power
Factor Correction (Active PFC). Active PFC
is used to improve the eciency of power
delivery. The current US Energy Star® Program
Requirements for Computers (version 7.1)
mandates Active PFC for all power supplies over
100 watts. Additionally, programs such as 80
Plus® are often used to identify high eciency
power supplies with Active PFC.
OVERVIEW
The CST1500S provides complete power
protection from utility power that is not
always consistent. The CST1500S features
1030 Joules of surge protection. The unit
provides long lasting battery backup during
power outages with maintenance free
batteries. The CST1500S ensures consistent
power to your computer system and includes
software that will automatically save your
open files and shutdown your computer
system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CST1500S stabilizes inconsistent utility
power voltage to nominal levels that are safe
for equipment. Inconsistent incoming utility
power may be damaging to important data
files and hardware, but with Automatic Voltage
Regulation (AVR), damaging voltage levels
are corrected to safe
levels. AVR automatically
increases low utility power
and decreases high utility
power to a consistent and
safe output voltage.
DETERMINE THE POWER REQUIREMENTS
OF YOUR EQUIPMENT
1.
Ensure that the equipment plugged
into the outlet does not exceed the UPS
unit’s rated capacity (1500VA/900W for
CST1500S). If the rated capacities of the
unit are exceeded, an overload condition
may occur and cause the UPS unit to shut
down or the circuit breaker to trip.
2. There are many factors that can aect
the amount of power that your computer
system will require. It is suggested that
the load placed on the battery outlets not
exceed 80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, after receiving a
new UPS, to ensure the battery’s maximum
charge capacity, it is recommended that
you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge
feature. When the UPS is plugged into an
AC outlet, the battery will automatically
charge whether the UPS is turned on or
turned o. Note: This UPS is designed with
a safety feature to keep the system from
being turned on during shipment. The first
time you turn the UPS on, you will need to
have it connected to AC power or it will
not power up.
2. With the UPS unit turned o and unplugged,
connect your computer, monitor, and any
other peripherals requiring battery backup
into the battery power supplied outlets.
Plug the other peripheral equipment (eg.
printer, scanner, speakers, etc.) into the
full time surge protection outlets. DO NOT
plug a laser printer, paper shredder, copier,
space heater, vacuum cleaner, sump pump
or other large electrical device into the
“Battery and Surge Protected Outlets”.
The power demands of these devices will
overload and possibly damage the unit.
3. Plug the UPS into a 2-pole,
3- wire grounded receptacle
(wall outlet). Make sure the
wall branch outlet is protect-
ed by a fuse or circuit breaker and does
not service equipment with large electrical
demands (e.g. air conditioner, refrigerator,
copier, etc.). The warranty prohibits the
use of extension cords, outlet strips, and
surge strips.
-continued
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | CST1500S |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower CST1500S stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024