SMART APP SINEWAVE UPS SERIES
PR2200RTXL2UHVACN / PR3000RTXL2UHVACN
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
FEATURES
6. Battery Backed and Surge
Protected Outlets
7. Output Circuit Breaker
8. SNMP/HTTP Network Slot
9. Cloud Monitoring (Ethernet Port)
10. Input Circuit Breaker
11. AC Inlet
12. BM Port
13. Dry Contact
14. Serial Port
15. USB Port
16. EPO/ROO Port
17. TVSS Screw
18. Extended Battery Module
Connector Socket
1. Power Switch
2. Toolless Battery Access Door
(behind faceplate)
3. Front Panel Access Tabs
(behind faceplate)
4. LCD Module
5. Faceplate
13 141516 17
18 12
6 7 8 9 10 11
5 34
1 2
Thank you for purchasing a CyberPower product. Please take a few minutes to register your
product at www.cyberpowersystems.com/registration. Registration certifies your product’s
warranty, confirms your ownership in the event of a product loss or theft and entitles you to free
technical support. Register your product now to receive the benefits of CyberPower ownership.
CAUTION! The UPS must be connected to a
grounded AC power outlet with fuse or circuit
breaker protection. DO NOT plug the UPS into
an outlet that is not grounded. If you need
to de-energize this equipment, turn o and
unplug the UPS.
CAUTION! The battery can energize
hazardous live parts inside even when the
AC input power is disconnected.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature
and humidity controlled indoor area, free
of conductive contaminants. Please see
specifications for acceptable temperature and
humidity range.
CAUTION! For pluggable equipment, the
socket-outlet shall be installed near the
equipment and shall be easily accessible.
CAUTION! To reduce the risk of electric shock,
do not remove the cover, except to service the
battery. There are no serviceable parts inside,
except for the battery.
CAUTION! To avoid electrical shock, turn o
the unit and unplug it from the AC power
source and disconnect external battery
connector before servicing the battery.
CAUTION! When installing the equipment,
ensure that the sum of the leakage current of
the UPS and the connected equipment does
not exceed 3.5mA.
CAUTION! Do not unplug the unit from AC
Power during operation, as this will invalidate
the protective ground insulation.
CAUTION! To reduce the risk of fire, connect
the UPS to a circuit with maximum rated 20
amperes and short-circuit current minimum
rated 1000 amperes over-current protection in
accordance to CE requirement.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit overcurrent
protection in accordance with the National
Electric Code, ANSI/NFPA 70.
CAUTION! DO NOT USE FOR MEDICAL OR
LIFE SUPPORT EQUIPMENT! DO NOT use in
any circumstance that would aect operation
or safety of any life support equipment, with
any medical applications, or patient care.
CAUTION! DO NOT USE WITH OR NEAR
AQUARIUMS! To reduce the risk of fire, do
not use with or near aquariums. Condensation
from the aquarium can come in contact
with metal electrical contacts and cause the
machine to short out.
CAUTION! DO NOT INSTALL THE UPS
WHERE IT WOULD BE EXPOSED TO
DIRECT SUNLIGHT OR NEAR A STRONG
HEAT SOURCE!
CAUTION! DO NOT BLOCK OFF
VENTILATION OPENINGS AROUND
THE HOUSING!
CAUTION! DO NOT USE THE UPS ON ANY
TRANSPORTATION! To reduce the risk of fire
or electric shock, do not use the unit on any
transportation such as airplanes or ships. The
eect of shock or vibration caused during
transit and the damp environment can cause
the unit to short out.
CAUTION! Dispose of or recycle the product
after the end of its life in accordance with
local regulations.
CAUTION! The output cable should not
exceed 10m in length.
CAUTION! EPO function is provided in UPS.
EPO remote switch which is Push-Back button
is installed computer room outside by a phone
line, and not connected any other equipment.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important instructions that should be followed during installation and
maintenance of the UPS and batteries. Please read and follow all instructions thoroughly before
and during the installation and operation of the product.
INSTALLING YOUR UPS SYSTEM
SYSTEM FUNCTION BLOCK DIAGRAM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) Faceplate
(c) Rail Kit CP2RAIL02, includes:
14 x M5 Pan Head Screws
8 x Plastic Washers
(d) Management cables
1 x USB Cable
1 x EPO Cable
(e) User’s Manual
(f) Mechanical Accessory, includes:
4 x Rack-Mount Brackets CPEAR04
2 x Rack-Mount Handles
2 x Tower Baseplates
12 x Dust Covers
4 x M5 Truss Head Screws
8 x M5 Flat Head Screws
8 x M4 Flat Head Screws
4 x Rubber Feet
4 x M4 Round Head Screws
OVERVIEW
The CyberPower Smart App
Sinewave Uninterruptible Power
Supply PR2200RTXL2UHVACN/
PR3000RTXL2UHVACN features 2430
Joules of surge protection, provides battery
backup during power outages and is Active
PFC compatible for safeguarding mission-
critical servers, telecom equipment, VoIP
and internetworking hardware that require
seamless sine wave power. Its full Automatic
Voltage Regulation (AVR) boost/buck
technology delivers a consistent and clean
AC power, protecting connected equipment
and preventing costly business interruptions.
This UPS is GreenPower UPS™ Bypass circuitry
patented to save on energy costs by reducing
energy consumption and heat buildup.
The UPS unit incorporates microprocessor-
based full digital control and includes
PowerPanel® Business software providing the
user unsurpassed flexibility and control. An
optional SNMP/HTTP Remote Management
adapter (RMCARD) supports remote
management and control of the machine
through a standard web browser.
AUTOMATIC VOLTAGE REGULATOR
The incoming utility
power may be damaging
to important data and
hardware, but with
Automatic Voltage
Regulation, the computer
will not experience
damaging voltage levels.
The AVR automatically
increases low or decreases high voltage to a
safe and consistent output voltage.
Input Output
Battery Mode
Normal Mode
EMI
Filter
Surge
Suppressor
Inverter
Charger
AC / DC
Battery
AVR
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | PR3000RTXL2UHVACN |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower PR3000RTXL2UHVACN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
28 Januari 2025
28 Januari 2025
28 Januari 2025
28 Januari 2025
27 Januari 2025
27 Januari 2025
15 Januari 2025
8 December 2024
8 December 2024
15 November 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Xtreme
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
28 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 December 2024
14 December 2024
10 December 2024
10 December 2024