Adastra RZ45 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Adastra RZ45 (8 pagina's) in de categorie Mengpaneel. Deze handleiding was nuttig voor 83 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
RZ45 + TR86
REMOTE ZONE AUDIO MATRIX
Item ref. RZ45: 0 953. 45UK
TR86: 953.0 50UK
(optional CS-5 call station: 953.049UK)
User Manual
Version 1.1
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
RZ45 / TR86 / CS-5 User Manual
Introduction
Thank you for choosing the Adastra RZ45 remote audio matrix system for your distributed audio installation.
This unit is designed to offer a flexible and expandable solution for a wide array of commercial sound systems.
Please read this manual to gain the best results from your product and avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, wat ingress or other damage, consult qualified service personnel er
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the sym l are HAZARDOUS LIVE and should only be connected by qualified personnel bo
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or ele ric shock, do not expose any components to rain or moisture. ct
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
Check for correct mains voltage and condition of IEC lead before connecting to power outlet
Placement
This unit can be use free- d standing or fixed into a 19” rack
Ensure adequate support and access to controls and connectors when rack-mounting
Cleaning
Use a soft cloth with a neutral detergent to clean the housing as required
Do not use strong solvents for cleaning the unit
RZ45 / TR86 / CS-5 User Manual
Front panel
Rear panel
Connection
Ensure the Power ( ) is switched off until all input and output connections are in place. 21
The RZ45 is supplied with a TR86 wall remote control, which is required to operate one of the output zones.
Up to 4 more TR86 wall remote controls can be added to the system, depending on how many zones are
being deployed. Connect the supplied TR86 remote to one of the remote inputs (12) on the RZ45 rear panel
using standard network cable.
For remote announcement to all or any zones, an optional CS- call station (953.049UK) can be added to the 5
system. If a CS-5 call station is being used, connect this to the call station input (13) on the rear panel using
network cable.
For announcements to all zones from the main RZ45 unit, a paging microphone input is provided on the front
or rear panel (1, 20) If the paging microphone requires phantom power (e.g. condenser mic), enable this by .
pressing in the phantom power button (19)
Each TR86 remote control can select an audio source from 1, 2, 3 or 4/USB. Audi sources 1, 2 and 3 are line o
inputs which can be connected to the rear panel of the RZ45 via L+R RCA sockets (18) The output level for .
each of these can be trimmed using rotary level controls (17) to avoid overloading the zone output.
1.
Paging microphone input (XLR)
7.
USB port
2.
Page on/off button & indicator
8.
Media player controls & display
3.
Paging microphone level
9.
Monitor zone select
4.
Output zones level indicators
10.
Monitor level
5.
Output zones source indicators
11.
Monitor headphones output (3.5mm jack)
6.
Stereo AUX input (3.5mm jack)
12.
TR86 remote control inputs (RJ45)
18.
Line inputs (L+R RCA)
13.
CS-5 call station input (RJ45)
19.
+24V phantom power (to paging mic)
14.
24Vdc emergency mute contacts
20.
Paging microphone rear input (XLR)
15.
Emergency audio line input
contacts
21.
Mains power on/off switch
16.
Zone outputs (L+R RCA)
22.
Mains power inlet (IEC) with fuse holder
17.
Line input levels


Product specificaties

Merk: Adastra
Categorie: Mengpaneel
Model: RZ45

Heb je hulp nodig?

Als je hulp nodig hebt met Adastra RZ45 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Mengpaneel Adastra

Handleiding Mengpaneel

Nieuwste handleidingen voor Mengpaneel