Tripp Lite PowerAlert 12 Handleiding
Tripp Lite
UPS
PowerAlert 12
Lees hieronder de š handleiding in het Nederlandse voor Tripp Lite PowerAlert 12 (21 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/21
1
Userās Guide
PowerAlertĀ® Network Shutdown Agent Software
Note: PowerAlert is not required to operate your UPS system. For the latest PowerAlert updates, go to www.tripplite.com/products/power-alert
1111 W. 35th Street, Chicago, IL 60609 USA ā¢ www.tripplite.com/support
Copyright Ā© 2018 Tripp Lite. All Rights Reserved. All trademarks are the property of their respective owners.
1. Introduction 2 ...............................................................................................
2. Windows Implementation 3 ..........................................................................
2.1 Pre-Installation ......................................................................................3
2.2 Installation ............................................................................................ 3
2.3 Conļ¬guration .........................................................................................3
2.3.1 Event Settings 4 ............................................................................
2.3.2 Shutdown....................................................................................4
2.3.3 Command Execution 4 ...................................................................
2.3.4 Operating Mode 5 ..........................................................................
2.3.5 Security 5 ......................................................................................
2.4 System Tray Icon 6 ...................................................................................
2.5 Performing a Silent Installation of PowerAlert 6 ........................................
2.6 Using the paconļ¬g.ini File 6 ......................................................................
3. Linux Implementation 7 ................................................................................
3.1 Pre-Installation ......................................................................................7
3.2 Installation 7 ............................................................................................
3.3 Conļ¬guration 7 .........................................................................................
3.3.1 Conļ¬guring PANSA Using the Conļ¬guration File 7 ...........................
3.4 Uninstalling PANSA 9 ................................................................................
3.5 Using the poweralert.conf File 9 ...............................................................
4. VMware Implementation (ESXi Server Environments) 10 .............................
4.1 PANSA for VMware vSphere Management Assistant (vMA) 10 ....................
4.1.1 Installation 11 ...............................................................................
4.1.2 Conļ¬guration 12 .............................................................................
4.1.3 Modifying and Conļ¬guring Scripts 13 ..............................................
4.2 PANSA for Non-vMA Operating Systems 13 ...............................................
4.3 PowerAlert Local..................................................................................14
5. Troubleshooting 14 .......................................................................................
6. Technical Support 16 ....................................................................................
APPENDIX A ā Sample Scripts 16 .......................................................................
APPENDIX B ā poweralert.conf File 20 ...............................................................
2
1. Introduction
PowerAlert Network Shutdown Agent (PANSA) monitors one or two network-attached Tripp Lite UPS systems for speciļ¬c power events, takes
the appropriate action to gracefully shutdown operating systems or execute scripts, and protects systems from data loss or corruption.
Example actions include shutting down the computer receiving UPS backup power when the UPS enters a low battery condition or, in a
VMware application, signaling an ESXi Host to shut down. If the ESXi Host is a member of a high availability cluster, the desired response to
the On Battery event could be to shut down the virtual machines running on the host before shutting down the host itself. This Userās Guide
will cover the basic scenarios.
Feature Comments
Unattended computer operating system shutdown Must monitor WEBCARDLX, SNMPWEBCARD or
PowerAlert Local for shutdown signal
Autodiscovery of SNMP-enabled devices Discovers devices accessible on the network via
WEBCARDLX, SNMPWEBCARD and PowerAlert Local
(software version 12.04.0040 and above)
Figure 1.1: PowerAlert Network Shutdown Agent Key Features
This document is divided into three sections, each covering implementation with a different operating system / environment. Please refer to
the section that applies to your environment:
ā¢ Windows ImplementationSection 2.
ā¢ Linux ImplementationSection 3.
ā¢ VMware ImplementationSection 4.
3
2. Windows Implementation
2.1 Pre-Installation
Note: PANSA requires pre-installation conļ¬guration of ļ¬rewall software settings and/or WEBCARDLX/SNMPWEBCARD settings.
ā¢ Open UDP ports 161, 162, 3664 and 3665 on your computerās ļ¬rewall software and disable the Windows SNMP trap service.
ā¢ The host computer for the device PANSA will be monitoring must also have UDP ports 161, 162, 3664 and 3665 open on its ļ¬rewall
software.
ā¢ If PANSA will be conļ¬gured to monitor a WEBCARDLX or SNMPWEBCARD, enable the cardās SNMP access and deļ¬ne a read/write
community string (the default community string for ļ¬rmware version 12.04.0048 and above is ).tripplite
Warning: Do not install more than one edition of a PowerAlert product on a single computer.
If you have a previous version of PANSA installed, Tripp Lite recommends you manually uninstall it prior to installing the new version.
2.2 Installation
Go to www.tripplite.com/products/power-alert-network-shutdown-agent to download the latest PANSA installer package for Windows.
Once downloaded, double-click the PowerAlert installer and follow the on-screen prompts. The installer will attempt to uninstall previous
versions of PANSA (if this action was not performed during pre-installation).
If you experience issues installing PANSA, uninstall any current versions then right-click on the install ļ¬le and select āRun as Administratorā.
Current Windows platforms are supported.
2.3 Conļ¬guration
After installation, the option to launch the PANSA Console (Figure 2.3.1) becomes available. The Console contains all the controls required
to operate PANSA.
The āMonitored UPSā ļ¬elds will be blank when PANSA starts up for the ļ¬rst time. Click the āDiscover Agentsā button to open the discovery
settings window (Figure 2.3.2). Enter an IP address and community name ( is the default). You must click the āAdd to listā button tripplite
after each entry and can add multiple entries, if desired. Use the asterisk character (*) as a wildcard in the IP address ļ¬eld. For example,
192.168.1.* will cover 192.168.1.1 through 192.168.1.255. If you know the speciļ¬c IP address of the device you plan to monitor, enter
that address. If you are unsure what information to enter in the discovery settings window, contact your network administrator for assistance.
Figure 2.3.1
Figure 2.3.2
Note: PANSA attempts to discover compatible WEBCARDLX and SNMPWEBCARD ļ¬rmware, PowerAlert Local and previous versions of PowerAlert software, but
it does not search for PowerAlert Network Management System or other PowerAlert Network Shutdown Agents on the network.
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | PowerAlert 12 |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite PowerAlert 12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024