Tripp Lite AVRT450U Handleiding

Tripp Lite UPS AVRT450U

Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite AVRT450U (32 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
UPS Systems
Models:
AVRT450U, BC600TU, AVRT65OU, SMART550USB2
(Series Numbers AG-0300, AG-0303, AG-888E, AG-0395)
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
Español 11 • Français 21
18-11-060-933853.indb 1 11/20/2018 8:42:21 AM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings
may affect the warranty.
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust
or direct sunlight.
For best performance, keep the indoor temperature between 32º F and 104º F
(0º C and 40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
Only set the UPS upright on a sturdy flat surface. Do not block fans or ventilation holes, as
this will seriously inhibit the unit's internal cooling and cause product damage not covered
under warranty.
UPS Connection Warnings
Connect your UPS directly to a properly-grounded AC power outlet. Do not plug the UPS into
itself; this will damage the UPS.
Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS
ground connection.
Do not use extension cords to connect the UPS to an AC outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
The mains socket outlet that supplies the UPS should be easily accessible and located near
the UPS.
Equipment Connection Warnings
Install in accordance with National Electrical Code standards ANSI/NFPA
70 and Canadian Electrical Code, Part I, C22.1.
Short circuit backup protection and overcurrent protection is provided by
the building installation.
To reduce the risk of fire, connect only to a circuit provided branch circuit
overcurrent protection in accordance with the National Electrical Code,
ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1. The plug on
the power supply cord is intended to serve as the disconnect device. Be
sure that the socket-outlet is installed near the equipment and is made
easily accessible.
Important Safety Instructions
18-11-060-933853.indb 2 11/20/2018 8:42:21 AM
3
Important Safety Instructions
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS. This might
damage the UPS and may affect the surge protector and UPS warranties.
Connect the UPS to an outlet that is adequately protected against excess currents, short
circuits and earth faults as part of the building installation.
Battery Warnings
Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. There are no user-serviceable parts inside the UPS. Do not
open the UPS except to perform battery replacement. Do not open batteries. Do not
short or bridge the battery terminals with any object. Do not dispose of batteries in a fire.
The batteries may explode. Released material is harmful to the skin and eyes. It may be
toxic. Unplug and turn off the UPS before performing battery replacement. Use tools with
insulated handles. Battery replacement should be performed only by authorized service
personnel using the same number and type of batteries (sealed lead-acid). Do not dispose
of the batteries in a fire. Tripp Lite offers a complete line of UPS System Replacement
Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/products/battery-
finder to locate the specific replacement battery for your UPS.
CAUTION: A battery can present a risk of electrical shock and high short-
circuit current. Contact with any part of a grounded battery can result in
electrical shock. The following precautions should be observed when working
on batteries:
Remove watches, rings or other metal objects.
Use tools with insulated handles.
Wear rubber gloves.
Do not lay tools or metal parts on top of batteries.
Unplug the UPS from the AC mains receptacle. Disconnect all cables, including the
equipment plugged into the UPS.
UPS and Battery Recycling
Tripp Lite products use sealed lead-acid batteries, which are highly recyclable.
Call Tripp Lite at 1.773.869.1234 or visit www.tripplite.com/support/recycling-
program for more information on recycling the batteries or any other Tripp Lite
product. Please refer to local codes for disposal requirements.
18-11-060-933853.indb 3 11/20/2018 8:42:21 AM


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: AVRT450U
Kleur van het product: Zwart
Gewicht: 4810 g
Breedte: 121.9 mm
Diepte: 345.4 mm
Hoogte: 160 mm
Snoerlengte: 1.5 m
Gewicht verpakking: 5310 g
Breedte verpakking: 182.9 mm
Diepte verpakking: 414 mm
Hoogte verpakking: 248.9 mm
Gebruikershandleiding: Ja
Materiaal behuizing: Acrylonitrielbutadieenstyreen (ABS)
LED-indicatoren: Ja
Vormfactor: Tower
USB-poort: Ja
Meegeleverde kabels: USB-kabel
Land van herkomst: Vietnam
Geluidsalarm(en): Ja
Responstijd: 0 ms
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 360 W
Temperatuur bij opslag: -15 - 45 °C
Frequentie: 50/60 Hz
Hoogte, in bedrijf: 0 - 3000 m
Power factor: 0.8
Stekker: NEMA 5-15P
(Buitenste) hoofdverpakking hoogte: 248.9 mm
(Buitenste) hoofdverpakking breedte: 182.9 mm
(Buitenste) hoofdverpakking brutogewicht: 5310 g
(Buitenste) hoofdverpakking lengte: 414 mm
Hoeveelheid per (buitenste) hoofdverpakking: 1 stuk(s)
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Surge energy rating: 316 J
Aantal AC uitgangen: 6 AC-uitgang(en)
Stopcontacttypes: NEMA 5-15R
Stroom (max.): 5 A
Output power capacity: 0.45 kVA
Ingang operation voltage (min): 110 V
Ingang operation voltage (max): 120 V
Uitgang operation voltage (min): 110 V
Uitgang operation voltage (max): 120 V
UPS-topologie: Line-interactive
Aantal input fases: 1
Typische backup tijd op halve lading: 5.7 min
Hoorbare alarmstanden: Fault, Low battery alarm, Overload alarm
EMI/RFI geluidsfiltering: Ja
Golfvorm: Sinus
Koude start: Ja
Automatic Voltage Regulation (AVR): Ja
Oplaadduur batterij: 8 uur
Overdrachtstijd (Lijnmodus naar batterijmodus): 6 ms