Oliveri Essente SS31670 Handleiding
Lees hieronder de đź“– handleiding in het Nederlandse voor Oliveri Essente SS31670 (4 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/4
Technical Data
Installation Instructions
TF 184 - SS 70 installation instructions.pdfd 316
Essente
Stainless Steel Goose Neck MixerSquare
SS31670 / SS31670-AU / SS31670-BL / SS31670-GM
CARE & MAINTENANCE
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water
pressure. The finish on your Oliveri mixer tap will resist stains and dirt build up.
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning.
Avoid using abrasive or acid based cleaning products.
WARRANTY FOR DOMESTIC USE
This mixer tap is warranted to be free from manufacturing defects for a period of
1 Years: Cartridge: 1 years replacement parts, 1 year labour; Body including handle: 5 5
7 years replacement parts and labour; Finish: 5 years replacement parts, 1 year labour;
Seals, tails, aerators: 1 year replacement parts and labour.
Where a genuine manufacturing defect arises within the warranty period Oliveri will, at
its election, repair the defect or replace the product subject to the terms contained in the
full warranty information available at https://oliveri.com.au/service-and-warranty.
This warranty does not cover against normal wear and will be voided if the
product is misused or not installed in accordance with these instructions. Note:
Fitting spout-attached devices, including water filters, to this mixer will void warranty.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur,
immediately shut off the water supply. If the mixer tap requires servicing, please
contact your plumber (preferably the one who installed it). Most problems occur due to
contaminated supply lines or water pressure exceeding 500kPa. Unscrew and clean the
spout aerator periodically - especially if you notice a drop in water pressure.
If the plumber / installer is satisfied that the problem is not due to poor installation,
contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: (08) 8348 6444 (choose the after sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
THIS MIXER TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS.
This Oliveri tap is manufactured to standard AS/NZS 3718.
Before attempting any work involving mains water supply lines, ensure the water supply is
shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri mixer to allow
isolation (not supplied with mixer). Failure to do so where required will void warranty.
This mixer tap is already pre-assembled and tested. Do not disassemble, as this may void
the warranty.
This mixer tap must be installed in accordance with these instructions.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena Rd, Regency Park SA 5010 P 08 8348 6444 E sales@oliveri.com.au
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure.
Note: Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent
removal by hand.
Note: Ceramic Cartridges - Warranty claims will not be honoured where the ceramic
cartridge has malfunctioned due to the presence in the water supply of;
• Copper tube pieces, sand, dirt or stones
• Thread tape
• Other objects not normally present in potable water supplies.
Do not remove the cartridge from the body as it has been pressure tested and
tightened to a specific torque.
MAX OPERATING PRESSURE: ...................................................... 5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE: ................................... 1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE: ............................................. 65°C
RECOMMENDED HOT WATER TEMPERATURE: ............................ 50°C
This product complies with the Lead Free requirements of the National
Construction Code Volume 3.
Installation Instructions
1. Remove product packaging and check for damage, the product is damaged do from if not
install and return to store of purchase.
2. The aerator WELS compliant has been pre-assembled into the mixer outlet. To comply with
WELS the flow regulated aerator must remain in place.
3. Ensure Product as exploded is complete per drawing.
4. A single hole required in the 35mm is mounting surface.
5. The maximum mounting surface thickness cannot exceed 37mm.
6. Ensure bench in place on of the sealing washer (A) is base Mixer.
7. Screw the tails (B) into base of careful avoid damage to the Mixer the Mixer being to o’ring
seals, the inlet ports red for blue Mixer are colour-coded, hot and for cold. Hand tighten only.
8. Feed the tails through the each end and position Mixer mounting surface, alternatively the
mixer on the surface the washer (A) is mounting ensuring sealing positioned correctly.
9. Feed tails, each through Plate Mixer alternatively Stabiliser (C).
10. Slide onto Mixer thread Metal Washer Rubber Washer (D) followed by (E).
11. Using Nut Mixer to mounting Fixing (F tighten) su Fixing (G)rface, lock Nut in place with screws
12. Connect Mixer tails to mains water 1/2"stop cock. Tighten to 10Nm. Do NOT overtighten.
13. Ensure the tails are not kinked, or when toMixer bent, stretched twisted assembling
the water supply. The Mixer between mixer mains Tail connection the and the water
supply must have a natural curve (minimum bend radius 30 mm).
14. Ensure Mixer tails are installed indoors, above-ground, and remain accessible - do not bury,
submerge, install behind a wall, floor or ceiling. Do not not expose to abrasions, corrosive
agents or the like. Test for leaks: If a leak occurs, retighten slightly.
15. It is recommended that in-line filters installed to ensure a cleaner flow of water to the be mixer.
GENERAL NOTE
This product is to be installed by
a licensed plumber, installation
must comply with AS/NZS 3500
and local plumbing codes.
A
C
D
E
F
G
B
Max 37
PRESSURES & TEMPERATURES
Maximum Hydrostatic Pressure – 500kPa. (As per AS/NZ S3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that ”Provision shall be made to ensure that
the maximum static pressure at any outlet, other than a fire service outlet, within a building does
not exceed 500kPa.” Pressures above 500kPa can cause damage from water hammer, Note:
reduced life of appliances, taps and fittings, and cause excessive noise in the system. Minimum
Hydrostatic Pressure 100kPa. :Note: This Product may not be suitable for use with low pressure/
gravity feed water supplies or with some continuous flow/instantaneous hot water systems. The
maximum operating temperature for the Mixer Tap is 65ÂşC. The recommended maximum
delivery temperature is 50ÂşC.
Please ensure that the lines are flushed prior to installation as contaminates in the
water can damage the Ceramic Cartridge, flow regulator and also affect the
performance of the Mixer.
Note: This mixer is designed to have the handle to the right hand side of the mixer, doing so will
put the cold inlet to the front of the mixer, the purpose is to assist with accidental scalding if a
child pulls the handle forward trying to turn on the mixer, installing the handle to the centre will
put the cold on the left hand side which is not recommended.
TO THE CONSUMER
1. The mixer is to only be cleaned with warm soapy water.
2. Under no circumstances should any abrasive, cream or acid based cleaning agents be used
as these types of cleaners will damage the tap finish, cartridge, seals and aerators.
TF 184 - SS 70 installation instructions.pdfd 316
Product specificaties
Merk: | Oliveri |
Categorie: | Kraan |
Model: | Essente SS31670 |
Heb je hulp nodig?
Als je hulp nodig hebt met Oliveri Essente SS31670 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Kraan Oliveri
20 November 2024
20 November 2024
20 November 2024
25 Juli 2024
25 Juli 2024
22 Maart 2024
19 Maart 2024
12 Maart 2024
12 Maart 2024
4 Maart 2024
Handleiding Kraan
- Kraan IKEA
- Kraan Etna
- Kraan Inventum
- Kraan Brita
- Kraan Delta
- Kraan Ernesto
- Kraan Franke
- Kraan Grohe
- Kraan Hansgrohe
- Kraan Hotto
- Kraan KitchenAid
- Kraan Livarno
- Kraan Lynx
- Kraan Miomare
- Kraan Quooker
- Kraan Smeg
- Kraan Stiebel Eltron
- Kraan Teka
- Kraan Concept
- Kraan Elba
- Kraan Blanco
- Kraan Caple
- Kraan CDA
- Kraan Curaqua
- Kraan SchĂĽtte
- Kraan Lamona
- Kraan Nodor
- Kraan Empire
- Kraan Brauer
- Kraan Elkay
- Kraan Oras
- Kraan Berg
- Kraan Mizzo
- Kraan ZLine
- Kraan Moen
- Kraan Mueller
- Kraan Aloni
- Kraan WillieJan
- Kraan Everpure
- Kraan Sani-Lav
- Kraan Fala
- Kraan Neo
- Kraan Lomazoo
- Kraan American Standard
- Kraan Livarno Lux
- Kraan Billi
- Kraan SaniSupreme
- Kraan Deante
- Kraan Omnires
- Kraan Vola
- Kraan Zip
- Kraan The Galley
- Kraan Viidako
- Kraan Waltec
- Kraan Gessi
- Kraan Puretec
- Kraan Sussex
- Kraan Fantini
- Kraan Rogerseller
- Kraan Axor
- Kraan Graff
- Kraan Zurn
- Kraan Karran
- Kraan Symmons
- Kraan Jacuzzi
- Kraan Rohl
- Kraan ProFlo
- Kraan Pfister
Nieuwste handleidingen voor Kraan
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024