Oliveri Essente SS31620 Handleiding

Oliveri Kraan Essente SS31620

Lees hieronder de đź“– handleiding in het Nederlandse voor Oliveri Essente SS31620 (4 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Technical Data
Installation Instructions
TF 181 - SS 20 nstallation nstructions.pdfd316 I I
Essente
Stainless Steel Goose Neck Mixer
SS31620 / SS31620-AU / SS31620-BL / SS31620-GM
CARE & MAINTENANCE
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water
pressure. The finish on your Oliveri mixer tap will resist stains and dirt build up.
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning.
Avoid using abrasive or acid based cleaning products.
WARRANTY FOR DOMESTIC USE
This mixer tap is warranted to be free from manufacturing defects for a period of
15 Years: Cartridge: 15 years replacement parts, 1 year labour; Body including handle:
7 years replacement parts and labour; Finish: 5 years replacement parts, 1 year labour;
Seals, tails, aerators: 1 year replacement parts and labour.
Where a genuine manufacturing defect arises within the warranty period Oliveri will, at
its election, repair the defect or replace the product subject to the terms contained in the
full warranty information available at https://oliveri.com.au/service-and-warranty.
This warranty does not cover against normal wear and will be voided if the
product is misused or not installed in accordance with these instructions. Note:
Fitting spout-attached devices, including water filters, to this mixer will void warranty.
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation
for any other reasonably foreseeable loss or damage. You are also entitled to have the
goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur,
immediately shut off the water supply. If the mixer tap requires servicing, please
contact your plumber (preferably the one who installed it). Most problems occur due to
contaminated supply lines or water pressure exceeding 500kPa. Unscrew and clean the
spout aerator periodically - especially if you notice a drop in water pressure.
If the plumber / installer is satisfied that the problem is not due to poor installation,
contact Oliveri’s nominated Warranty Service Agent for assistance on:
Ph: (08) 8348 6444 (choose the after sales service and warranty option)
Email: warranty@oliveri.com.au
For full warranty information visit: https://oliveri.com.au/service-and-warranty
If a warranty service call finds that the product does not have a genuine
manufacturing fault, our Warranty Service Agent reserves the right to pass on
any call-out fee to the householder.
THIS MIXER TAP MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS.
This Oliveri tap is manufactured to standard AS/NZS 3718.
Before attempting any work involving mains water supply lines, ensure the water supply is
shut off.
Stop valves (preferably with filters) must be used when installing your Oliveri mixer to allow
isolation (not supplied with mixer). Failure to do so where required will void warranty.
This mixer tap is already pre-assembled and tested. Do not disassemble, as this may void
the warranty.
This mixer tap must be installed in accordance with these instructions.
Oliveri Solutions Pty Ltd ABN 12 007 551 886
51 Naweena Rd, Regency Park SA 5010 P 08 8348 6444 E sales@oliveri.com.au
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed.
Note that water pressure overnight can reach 150% of the daytime pressure.
Note: Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent
removal by hand.
Note: Ceramic Cartridges - Warranty claims will not be honoured where the ceramic
cartridge has malfunctioned due to the presence in the water supply of;
• Copper tube pieces, sand, dirt or stones
• Thread tape
• Other objects not normally present in potable water supplies.
Do not remove the cartridge from the body as it has been pressure tested and
tightened to a specific torque.
MAX OPERATING PRESSURE: ...................................................... 5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE: ................................... 1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE: ............................................. 65°C
RECOMMENDED HOT WATER TEMPERATURE: ............................ 50°C
This product complies with the Lead Free requirements of the National
Construction Code Volume 3.
Installation Instructions
1. Remove the do product from damages, packaging and check for if product damaged is not
install and store return to of purchase.
2. The been into WELS compliant aerator has pre-assembled the mixer outlet. To comply with
WELS the in flow regulated aerator must remain place.
3. Ensure complete exploded Product is as per drawing.
4. A single 35mm Hole in the is required mounting surface.
5. The exceed maximum mounting surface thickness cannot 37mm.
6. Ensure Mixer.bench in place on sealing washer (A) is base of
7. Screw the damage Mixer tails (B) into base being avoid of the Mixer careful to to the o’ring
seals. The Mixer inlet ports are colour-coded, red for hot and blue for cold. Hand tighten only.
8. Feed the through the each end Mixer tails mounting surface, alternatively, theand position
mixer on the the mounting surface ensuring sealing washer (A) is positioned correctly.
9. Feed each through Mixer tails, alternatively Stabiliser Plate (C).
10. Slide onto thread Rubber Washer (D) Mixer followed by Metal Washer (E).
11. Using Fixing Nut (F) tighten Mixer to mounting surface, lock Fixing Nut in place with screws (G)
12. Connect Mixer tails to mains water 1/2"stop cock. Tighten to 10Nm. Do NOT overtighten.
13. Ensure the Mixer tails are not kinked, bent, stretched or twisted when assembling to
the mains water supply. The Mixer Tail connection between the mixer and the water
supply must have a natural curve (minimum bend radius 30 mm).
14. nsure Mixer tails are installed indoors, above-ground, and remain accessible - do not bury,E
submerge, install behind a wall, floor or ceiling. Do not not expose to abrasions, corrosive
agents or the like. Test for leaks: If a leak occurs, retighten slightly.
15. It is recommended that in-line filters be installed to ensure a cleaner flow of water to the mixer.
A
C
D
E
F
G
B
GENERAL NOTE
This product is to be installed by
a licensed plumber, installation
must comply with AS/NZS 3500
and local plumbing codes.
Max 37
PRESSURES & TEMPERATURES
Maximum Hydrostatic Pressure – 500kPa. (As per AS/NZS 3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that ”Provision shall be made to ensure that
the maximum static pressure at any outlet, other than a fire service outlet, within a building does
not exceed 500kPa.” Pressures above 500kPa can cause damage from water hammer, Note:
reduced life of appliances, taps and fittings, and cause excessive noise in the system. Minimum
Hydrostatic Pressure 100kPa. :Note: This Product may not be suitable for use with low pressure/
gravity feed water supplies or with some continuous flow/instantaneous hot water systems. The
maximum operating temperature for the Mixer Tap is 65ÂşC. The recommended maximum
delivery temperature is 50ÂşC.
Please ensure that the lines are flushed prior to installation as contaminates in the
water can damage the Ceramic Cartridge, flow regulator and also affect the
performance of the Mixer.
Note: This mixer is designed to have the handle to the right hand side of the mixer, doing so will
put the cold inlet to the front of the mixer, the purpose is to assist with accidental scalding if a
child pulls the handle forward trying to turn on the mixer, installing the handle to the centre will
put the cold on the left hand side which is not recommended.
TO THE CONSUMER
1. The mixer is to only be cleaned with warm soapy water.
2. should any abrasive, cream or acid based cleaning agents be usedUnder no circumstances
as these types of cleaners will damage the tap finish, cartridge, seals and aerators.
TF 181 - SS 20 nstallation nstructions.pdfd316 I I


Product specificaties

Merk: Oliveri
Categorie: Kraan
Model: Essente SS31620

Heb je hulp nodig?

Als je hulp nodig hebt met Oliveri Essente SS31620 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kraan Oliveri

Handleiding Kraan

Nieuwste handleidingen voor Kraan