Shaws AUSH-4861 Handleiding

Shaws Kraan AUSH-4861

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Shaws AUSH-4861 (8 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
mm
hole
COLD
IN
HOT
IN
G 1/2”
G 1/2”
G 1/2” to suit
dual check valve
Con-Serv DCξ˜ξ˜‚ξ˜CFF
ξšξ˜žξ˜‚mm
ξ˜Ÿξ˜žξ˜‚mm
hole
Silverdale
AUSH.4861 - MONOBLOC MIXER
AUSH.4866 - MONOBLOC MIXER WITH SPRAY RINSE
I M P OR T E R S & D I S T R I B U T O R S O F F I N E K I T C HE N A N D B AT H R O OM WA R E
 6ξ˜›  |  French Avenue, Brendale QLD 4500 | aftersales@luxebydesign.com.au | www.luxebydesign.com.au
Please Note: This model does not suit incoming water pressure
below 100kPa or higher than 500kPa. The spray rinse model requires
a minimum inlet pressure of 100kPa to successfully divert the water
flow from the main tap to the spray rinse. The stop cocks provided
with this tap contain gauze filters. Please ensure your plumber is
advised of the minimum and maximum water pressure, and to install
the stop cocks as failure to do so voids the tap warranty.
Temperature Range Min 1Β°C. Max 70Β°C
Working Pressure Min 100kPa (14.5psi). Max 500kPa (72.5psi)
Flow Rates AUSH.
 Bar: ξ˜—ξ˜–ξ˜œL/min
 Bar: ξ˜šξ˜šξ˜–ξ˜•L/min
 Bar: ξ˜šξ˜•ξ˜–ξ˜•L/min
AUSH.6
 Bar: ξ˜”ξ˜–ξ˜œL/min
 Bar: ξ˜“ξ˜–ξ˜•L/min
 Bar: L/min
Ideal performance obtained with equal hot & cold pressures.
COLD
IN
HOT
IN
Non-return valve adaptor
Dual check valve
Con-Serv DCξ˜‹ξ˜Šξ˜ŠCFF
G 1/2”G 1/2”
WORK SURFACE
mm
Hole
ξšξšξ˜‹mm
hole
6ξ˜‹
ξš‚ξ˜‹mm max
ξšξš„ξš…
ξš…ξšξ˜Š
ξš…ξš†ξ˜Š
ξš†ξš…ξš„
Hose Length
ξš†ξš…ξ˜‹ξ˜‹mm
Silverdale | INSTALLATION AND USER GUIDE
1Ensure the mixer is oriented correctly, the hot lever
should be on the left when viewed from the front. Hot
and cold hoses are indicated with a red or blue sticker.
We recommend a minimum distance of 70mm from
the wall to the hole centre for the main tap.  x mm
hole is required to mount the mixer. If you have a spray
rinse model, an additional ξ˜žξ˜ξ˜›mm hole located to the
left or right hand side of the tap is also required for
the spray rinse unit. Maximum counter top thickness is
40mm. Extension kits are available for thicker benchtops.
Insert the flexible connectors through the hole,
ensuring that the base ring and seal are in place
between the mixer and the mounting surface.
From the underside of the counter top, place the
clamp plate on securing stud and using the box spanner
supplied, place the fixing nut in the spanner and tighten
until the mixer is held firmly in position.
If your mixer has a rinse, please follow steps 2, 3 & 4 to
install correctly, otherwise please connect the hot &
cold water supplies..
Ensure all connections are firmly tightened.
3Ensure the black rubber washers are situated inside position A, B
(either side of NRV) and C on the rinse hose, including the NRV
adaptor in sequence as displayed in the diagram.
Screw the rinse onto the end of the flexible hose from the tap.
Ensure the connection is firmly tightened.
4
Thread the tapered end of the rinse flex hose into the rinse
unit, ensuring the rubber seal is in place between them.
Ensure all connections are firmly tightened.
2
Secure the rinse unit socket in a suitable position using a tap
wrench of a 36 AF spanner.
Place the flexible hose through the top of the rinse unit socket as
shown in the diagram.
LUXEBYDESIGN.COM.AU
ΓΈ30mm
Hole
WORK SURFACE
Base seal
Rinse unit
socket
Fibre washer
Backnut
Flexible hose
WORK SURFACE
A
C
B
Rinse
hose Dual
check
valve
NRV
adaptor
G 3/8”
Base ring
Base seal
Clamp plate
Fixing nut
Flexible
connections
WORK SURFACE
WORK SURFACE
ΓΈ35mm
Hole
ΓΈ30mm
Hole
Base seal
Rinse unit
socket
Black rubber
washer
Fibre washer
Flexible hose
Backnut
Rinse
BEFORE USE  Carefully check the installation for leaks
 If further building work is being carried out in the vicinity, cover the product to avoid damaging the finish.
 Please ensure the installation complies with the water supply by-laws.
Congratulations on the purchase of your Shaws by Perrin & Rowe kitchen product. Correctly installed and with sensible care,
this product will give you many years of trouble-free service.
INSTALLATION REQUIREMENTS
Perrin & Rowe tapware must be installed by a Licensed Plumber in accordance with the installation instructions provided, best
trade practices and must comply to local plumbing regulations in your area. Incorrect installation may damage your tap and
could invalidate your warranty.
 Where the inlet water pressure exceeds 500kpa, pressure limiting valves must be installed.
 In-line gauze filters must be fitted in the incoming water supply lines.
 Prior to installation, it is important to flush all incoming water lines thoroughly. Failure to do so may result in issues caused
by debris in the water supply such as bits of metal or plastic, dirt, sand, rust, silt, and other unwanted materials. Any
problems that arise as a result of inadequate flushing may not be covered by the warranty.
 Please take care of this product before, during and after installation as accidental damage to the tap finish is not covered
by the warranty. Please wear gloves when handling 'living finish' models. If further work is to be carried out in the vicinity of
the product, please cover it to protect from paint, plaster, adhesives, sealants and cleaning products.
 For ease of possible future servicing, we recommend the fitting of conveniently placed isolating valves.
 Once unpacked, remove fixing nuts, clamp plate, fibre washer and plastic backnut from tap assembly, ready for installation.
DISTRIBUTED IN AUSTRALIA BY LUXE BY DESIGN ξ˜— ξ˜›ξ˜– ξ˜ξ˜•ξ˜”ξ˜œ ξ˜–ξ˜Ÿξ˜ξ˜ ξ˜— AFTERSALES@LUXEBYDESIGNξ˜“COMξ˜“AU


Product specificaties

Merk: Shaws
Categorie: Kraan
Model: AUSH-4861

Heb je hulp nodig?

Als je hulp nodig hebt met Shaws AUSH-4861 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kraan Shaws

Handleiding Kraan

Nieuwste handleidingen voor Kraan