Nexa MSA-866 Handleiding

Nexa Rookmelder MSA-866

Lees hieronder de 📖 handleiding in het Nederlandse voor Nexa MSA-866 (2 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
MODEL : MSA- 866/10Y
LONGLIFE 10 YEARS BATTERY OPERATED
MINIATURE PHOTOELECTRIC
SMOKE ALARM WITH HUSH FEATURE
15
0086 632447- -CPR
Nexa13539 CPR- - 632447
EN14604:2005/AC:2008
Nexa Trading AB, Box 12200, 40242 Gothenburg
Sweden
Fire Safety and installed in buildings
Main Features :
Photoelectric Sensor for Slow Smouldering Fires
Long life Lithium Battery
Miniature Size
Hush Feature
Power & Alarm Test Button
Low Battery Warning
Loud 85db alarm signal
Supplied with wall plugs & screws
Pre-warning fault signal
Dust cover included
This instruction leaflet contains important information
on the correct installation and operation of your smoke
alarm. Read this leaflet fully before attempting
installation and retain for future reference.
SPECIFICATION
Power Source V Lithium cells 3: (CR123A/
/FDK .6L)CR2477 ½
Operation Current : <20mA operation (In Alarm)
Sensitivity to smoke 65- : 0. 1.52% per foot obscuration
Operation Temperature 0: oC-40oC
Ambient Humidity - : 10% 90%
Horn Level : 85 Decibels at 3 metres
Battery Life : approx. 12 years
Approval: Certified to BS EN14604:2005
LOCATING THE SMOKE ALARM
This smoke alarm is a single station photoelectric alarm and
should NOT be connected to other smoke alarms.
If your dwelling is on a single storey, for minimum protection
you should fit an alarm in the hallway between the living
areas (incl. Kitchens) and sleeping areas. Place it as near to
the living areas as possible and ensure the alarm is audible
when the bedrooms are occupied. See Figure 1 for
examples.
If your dwelling is multi-storey, for minimum protection one
alarm should be fitted at the bottom of the staircase with
further alarms fitted on each upstairs landing. This includes
basements but excludes crawl spaces and unfinished attics.
See Figure 2 for examples.
NOTE: For maximum protection an alarm should be fitted in
every room (except kitchen, bathroom and garage).
DO NOT FIT AN ALARM IN THE KITCHEN or BATHROOM,
as cooking fumes or steam may trigger the alarm.
DO NOT FIT ALARM IN A GARAGE, as exhaust fumes are
likely to set it off.
POSITIONING THE SMOKE ALARM
Ceiling Mounting
As hot smoke rises and spread out, it is advisable to mount
on a ceiling in a central position. Avoid areas where there is
no air circulation. E.g. Corners of rooms and keep away from
items which may prevent the free flow of air. Place the unit at
least 300mm from and light fitting or decorative object which
might obstruct smoke / heat entering the alarm. Keep at
least 300mm away from walls. See Figure 3i.
Wall Mounting
Do not mount tight into the corners. Put the top edge of your
smoke alarm between 150 and 300mm below the ceiling.
Keep at least 300mm from room corners. See Figure 3i
On a Sloping Ceiling
In areas with sloping or peaked ceilings install your Smoke
Alarm 900mm from the highest point measured horizontally
because “dead air” at the apex may prevent smoke from
reaching the unit. See Figure 3ii.
Areas to be avoided include the following :-
Situations where the temperature may fall below
0oC or rise above 40oC
Humid areas such as bathrooms, kitchens, shower
rooms where the relative humidity may exceed 90%
Near a decorative object, door, light fitting, window
molding etc., that may prevent smoke or heat from
entering the alarm.
Fume filled environments such as garages.
Exhaust gases may cause false alarms.
Adjacent to or directly above hot components such
as radiators or wall vents that can effect the
direction of air currents.
In very dusty or dirty environments such as
workshops.
Locate unit at least 1.5m and route wiring at least
1m away for fluorescent light fittings as electrical
“noise” and/or flickering may affect the unit. Do not
wire into the same circuit as fluorescent lights or
dimmers.
Do not locate in insect infested areas. Insects and
contamination on the Heat Alarm sensor can
increase its response time.
INSTALLING THE SMOKE ALARM
This smoke alarm is powered by battery and requires no
additional wiring.
Having established the mounting location ensure
that there in no electrical wiring or pipe work in the
area adjacent to the mounting surface.
Take the mounting bracket and mark the two
mounting hole locations.
Drill holes in the positions marked.
Insert wall plugs into the drilled holes.
Screw mounting bracket to mounting surface. DO
NOT OVER TIGHTEN.
Assemble detector onto the mounting plate by
aligning the two projections on the (A1) and (A2)
mounting plate with the two keyhole slots in the
detector.
Lock in position by giving a clockwise quarter
turn. This clockwise turn can switch on the
sealed-in battery in same time. i.e. power on the
device simultaneously
Test the alarm for correct operation using test
facility.
LANDING
HALL
BATHROOMBEDROOM
LIVING
ROOM
KITCHEN
BASEMENT
LIVING
ROOM
BATHROOM
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BEDROOM
HALL
MAXIMUM PROTECTION
MINIMUM PROTECTION
KEY
FIGURE 1 - SINGLE STOREY DWELLING
FIGURE 2 - 2/3 STOREY DWELLING
Let the dust cover remain over the smoke alarm until
the the final cleaning is completely done. Applies
mainly for new construction or renovation.
OPERATING YOUR SMOKE ALARM
Once the smoke alarm has been installed a small indicator
light (LED), positioned beside the test button, should flash
approximately once a minute in normal operation.
If smoke is detected the unit will emit a load pulsating alarm
until the air is clear.
TESTING YOUR SMOKE ALARM
It is recommended that you test your smoke alarm once a
week to ensure the detector is working correctly.
Push and hold the test button for approximately 3 seconds. A
loud pulsating alarm should sound to indicate the correct
function. During the alarm condition the indicator light will
flash quickly.
After installation and after reoccupation of the
dwelling following a vacation etc, check all your
alarms.
COMMON CAUSES AND AVOIDANCE OF
FALSE ALARMS
The Smoke Alarm may be triggered by steam, condensation,
normal smoke or fumes. Small insects getting into the smoke
alarm chamber may cause intermittent alarms. Keep away
from the sources to avoid nuisance alarms. (See "Areas to be
avoided" in the "Positioning the smoke alarm" section.)
Hush or Silence Feature
This Smoke Alarm has a built-in Hush or Silence feature
incorporated into the Test button.
If cooking or other non-hazardous sources cause the
unwanted alarm, it can be temporarily silenced by depressing
the test button and holding for approximately . The 1 second
alarm will enter a dormant period for 10 minutes. The red LED
will flash every 10 seconds to indicate the sensitivity is
reduced. At the end of the hush period the alarm will give two
short beeps, the alarm will then reset to normal sensitivity.
NOTE - If the smoke density increases during this period (i.e.
from a fire) the unit will go into alarm mode.
LOW BATTERY WARNING
If the smoke detector emits a short ‘beep’ once every 40
seconds the battery is at the end of its life and this detector
should be replaced immediately. This low voltage warning will
be given for at least 30 days.
If the red indicator light (LED) does not flash every 40
seconds then replace the whole smoke alarm unit.
BATTERY SEALED-IN NOT FOR
REPLACEMENT
ACTION IN THE EVENT OF A FALSE ALARM
If there is a false alarm, simply press the test / hush
button on the cover to mute the unit for 10 minutes.
Check the house carefully in case there is a small fire
smouldering somewhere.
Check whether there are some sources of smoke or
fumes. You should get your family into a safe place
before your investigation.
If there are frequent nuisance/ false alarms it may be
necessary to re-locate the device. If for some reasons
the alarm continues to give false alarm, the units can
be silenced by removing the batteries. If cleaning the
alarm does not correct the problem it can be returned
to the place where you bought it.
IN THE EVENT OF FIRE
Leave the building as quickly as possible. Check room
doors for heat or smoke. Do not open a hot door. Use
an alternate escape route. Crawl along the floor, if
possible, through a wet cloth or hold your breath. Do
not stop to collect anything.
Meet at a pre-arranged meeting place outside the
dwelling and check everybody is there.
Call the Fire Brigade from outside the building
immediately. The brigade should be summoned
regardless of the size of the fire and regardless of
whether there is a facility for transmission of alarms to
a remote manned centre.
Do not go back inside a burning building and wait for
the Fire Brigade to arrive.
MAINTAINING YOUR SMOKE ALARM
Clean your smoke alarm regularly to prevent dust build up.
This can be done using a vacuum cleaner with the brush
attachment. Clean gently around the front grilled section and
sides. Never use water, cleaners or solvents since they may
damage the smoke alarm.
When the battery is low, replace with a new smoke alarm.
If the alarm fails to operate currently, please send back to
the address of manufacturer shown on the back label of the
detector.
NOTE: THE APPARATUS SHALL NOT BE EXPOSED TO
DRIPPING OR SPLASHING.
________________________________________________
PRE-WARNING FAULT SIGNAL (YELLOW LED)
When there is no fire nor smoke accident, if the LED on
front cover lights on yellow, it means: may be dust go
inside or means the unit cannot function properly. This
is a pre-warning signal that the user should replace the
unit with a new smoke alarm._______________________
IMPORTANT SAFEGUARDS
Installation of your smoke alarm is only one step in your
safety plan. Other important steps should be taken to
further improve your safety:-
Install the smoke alarm properly, following this
instruction leaflet
Test your smoke alarm weekly
Replace with a new smoke alarm immediately once
depleted
Do not smoke in bed
Keep matches & lighters away from children
Store flammable materials in a proper manner and
never use them near naked flames or sparks
Maintain emergency equipment such as Fire
Extinguishers, escape ladders etc and ensure all
occupants know how to use them correctly.
Plan an escape route/s from your building in
advance and ensure all occupants are aware of
them. Re-enforce this awareness periodically
through- out the year.
Make sure escape routes remain free of any
obstructions.
A warning that batteries (battery pack or
batteries installed) shall not be exposed to
excessive heat such as sunshine, fire or
the like.
WARNING!
IF THERE IS ANY QUESTION AS TO THE CAUSE OF
AN ALARM IT SHOULD BE ASSUMED THAT THE
ALARM IS DUE TO AN ACTUAL FIRE AND THE
DWELLING SHOULD BE EVACUATED IMMEDIATELY.
THIS PRODUCT IS A SEALED UNIT AND CANNOT BE
REPAIRED – IF THE UNIT IS TAMPERED WITH IT WILL
INVALIDATE THE GUARANTEE. IF THE UNIT IS
FAULTY PLEASE RETURN IT TO YOUR ORIGINAL
SUPPLIER WITH YOUR PROOF OF PURCHASE.
YOUR SMOKE ALARM GUARANTEE
These Smoke Alarms are guaranteed to be free from
defects in materials and workmanships under normal use
and service for a period of five year s (exclude battery)
from date of purchase. The company will not be obligated
to repair or replace parts which are found to be in need of
repair because of misuse, damage or alterations occur
after the date of purchase. Send the Smoke Alarm with
proof of purchase, postage and return postage prepaid, to
local distributor. The liability of the company arising from
the sale of this Smoke Alarm shall not in any case exceed
the cost of replacement of Heat Alarm and in no case
shall the company be liable for consequential loss or
damages resulting from the failure of the Smoke Alarm.
NEXA TRADING AB NO LIABILITY FOR SHALL HAVE
ANY PERSONAL INJURY OR PROPERTY DAMAGE,
OR ANY SPECIAL INCIDENTAL, CONTINGENT OR
CONSEQUENTIAL DAMAGE OF ANY KIND
RESULTING FROM A FIRE. THE EXCLUSIVE
REMEDY FOR BREACH OF THE LIMITED
WARRANTY CONTAINED HEREIN IS THE REPAIR
OR REPLACEMENT OF THE DETECTIVE PRODUCT
AT NEXA TRADING AB OPTION. IN NO CASE SHALL
NEXA TRADING AB’S LIABILITY UNDER ANY OTHER
REMEDY PRESCRIBED BY LAW EXCEED THE
PURCHASE PRICE. YOUR SMOKE ALARMS IS NOT
A SUBSTITUTE FOR PROPERTY, DISABILITY, LIFE
OR OTHER INSURANCE OF ANY KIND.
APPROPRIATE COVERAGE IS YOUR
RESPONSIBILITY. CONSULT YOUR INSURANCE
AGENT
This does not affect your statutory rights.
This alarm is only suitable for single occupancy private
dwellings only and not intended for multi occupancy
private dwellings or commercial or industrial dwellings.
Waste electrical products should not be disposed of with
normal household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for
recycling advice. New regulation will encourage the
recycling of Waste from Electrical and Electronic
Equipment (European "WEEE Directive" effective
August 2005).
Manufacturer:
Nexa Trading AB
Sweden
www.nexa.se
You will find the Declaration of Performance on (DoP)
our website


Product specificaties

Merk: Nexa
Categorie: Rookmelder
Model: MSA-866

Heb je hulp nodig?

Als je hulp nodig hebt met Nexa MSA-866 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder Nexa

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Kidde

Kidde 3SFWR Handleiding

24 September 2024
Kidde

Kidde KF30R Handleiding

24 September 2024
Kidde

Kidde P4010ACS-WCA Handleiding

24 September 2024
Kidde

Kidde i12020CA Handleiding

24 September 2024
Kidde

Kidde i12040CA Handleiding

24 September 2024
Kidde

Kidde KF20R Handleiding

24 September 2024
Kidde

Kidde CP9000CA Handleiding

24 September 2024
Kidde

Kidde Pi2010CA Handleiding

24 September 2024