Master Lock LFW205TWC Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Master Lock LFW205TWC (60 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/60
519226
: Masterlock.eu/Safes
INSTRUCTIONS FOR USE 2 .........................................................
MODE D’EMPLOI 5 .....................................................................
GEBRAUCHSANWEISUNG .........................................................8
GEBRUIKSAANWIJZING ........................................................... 11
INSTRUCCIONES DE USO 14 ..........................................................
ISTRUZIONI PER LUSO 17 ............................................................
INSTRUÇÕES DE UTILIZAÇÃO 20 ....................................................
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ 23 ...................................................................
BRUKSANVISNING ..................................................................26
BRUGSANVISNING ................................................................. 29
KÄYTTÖOHJE ..........................................................................32
BRUKSANVISNING ..................................................................35
INSTRUKCJA UŻYCIA 38 ...............................................................
HASZNÁLATI ÚTMUTATÓ 41 ..........................................................
MOD DE UTILIZARE 44 .................................................................
NÁVOD K POUŽITÍ 47 ...................................................................
ИНСТРУКЦИЯ ПО ПPИMEHEHИЮ............................................. 50
KULLANIM TALİMATI ...............................................................53
使用説明書 ....................................................................... 56
2
ENGLISH
Your Master Lock Product
Your Master Lock product has a number of features to keep your
important documents and valuables protected including:
Water Protection UL Classified
Fire Protection
Digital Media
Protection
Loud Audible Alarm
THE LOUD AUDIBLE ALARM ALERTS YOU WHEN:
The safe is picked up
or moved
There is an attempt
to pry the door open
The wrong combination
is entered 5 times
Using Your Master Lock
Alarm Safe
Preparing Your Safe for First Time Use
1
2
3
Remove lock out screw indicated by the
yellow tag on the inside of the door
of the safe.
Remove battery compartment from
inside door and insert 4 AAA alkaline
batteries. DO NOT use rechargeable
batteries or any other type of non-
alkaline battery. Do not mix old and
new batteries. Do not mix alkaline and
standard batteries.
Replace battery compartment.
Using Your Safe
1
2
3
Touch the keypad to wake up the safe.
Enter the 5 digit factory code found on
the back of this owner’s manual.
Turn handle to open safe.
IMPORTANT: Test your code several times before putting
valuables inside.
IMPORTANT: If you exert too much force on the handle,
the handle will move without moving the bolts. When this
happens, you will hear a ’click.’ DO NOT be alarmed.
This feature is designed to protect the bolts from being
over powered by force. Simply exert force in the opposite
direction (lifting up) until the handle clicks back
into place.
1Close and lock the door of your safe.
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ 0 PROG 9
The alarm indicator will blink every
10 seconds to indicate the alarm has
been activated.
IMPORTANT: Like a home alarm system, the alarm must
be set each time you lock your safe to activate the
audible alert. In the event your alarm is not activated
and 5 wrong code attempts are entered, the safe will
go into delay mode for 2 minutes. No alarm will go off
when moved, jarred or with attempted forced entry.
2
Thank you for choosing Master Lock to store all your important documents and valuables.
We hope that this product will help you stay organized and provide you with the peace-of-mind of knowing the things most important to you are protected.
Water/Fire Resistant Alarm Safe
Setting the Alarm
Turning off the Alarm
If the loud audible alarm on your safe has been triggered:
1
2
Touch the keypad to wake up the safe.
Enter a valid code.
NOTE: You will need to enter your code again to open the safe.
NOTE: The Factory Code (FC) or User Code (UC) must be
entered to program safe settings. A secondary code cannot
be used.
Changing Alarm Sensitivity
You can change the level of sensitivity on your safe alarm from a scale
of zero “0” to “5”. Zero “0” being the least sensitive only responding
to incorrect codes and “5” being the most sensitive to slight
movement of the safe.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR 0 PROG PROG (FC) (UC) “ ”3
Then press OR to program your ”, “ ”, ”, “ ”, 01234 “ ”5
desired sensitivity.
3
Changing Length of Alarm
You may also change the length of which your alarm will sound once
triggered from 01 to 99 minutes.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR 0 PROG PROG (FC) (UC) “ ”4
Then press any number between 01 and 99 to indicate the
number of minutes you would like your alarm to sound
once triggered.
3
Audible Alarm
Features
The safe is jolted,
hit or jarred
3
FACTORY CODE (FC): The safe will ALWAYS unlock using this 5
digit code (found on the back of this owner’s manual). This code
cannot be deleted or changed.
USER CODE (UC): A 5 digit programmable code of your choosing
that can be changed or deleted.
SECONDARY CODE (SC): A 5 digit programmable code of your
choosing that can be changed or deleted. Can only be
programmed after a user code has been activated.
Programmable Codes
Your Master Lock safe comes with 3 types of codes for
accessing your safe. For more information on programming
these codes see the “Programming Safe Features” section of
this owner’s manual.
3
ENGLISH
WARNING: Product is not water resistant once it is bolted
down. The ETL verified water resistance claim applies to
product prior to the application of a bolt-down kit.
Programming Safe Features
OTHER PROGRAMMABLE SAFE FEATURES
Length of Interior Light
NOTE: The Factory Code (FC) or User Code (UC) must be
entered to program safe settings. A secondary code cannot
be used.
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR – “ 0 PROG PROG (FC) (UC) 2
Press: to program to turn off 0
o program for 30 seconds ” t1
o program for 60 seconds ” t2
Digital Keypad Sound On/Off
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR –“ 0 PROG PROG (FC) (UC) 1
Press: to turn on the digital keypad sound or 1
Press: to turn off the digital keypad sound 0
Programming Safe Features
BATTERY AUXILIARY OVERRIDE
If battery power in the safe is running low and cannot operate the
safe, you will need to use the Battery Auxiliary Override feature to
open the safe.
IMPORTANT: This should not be used as a primary means to
gain entry into the safe.
1
2
5
Open the silicone cap found on the side
of the lock.
Insert a 9 volt battery into this slot.
Touch the keypad to wake up the safe.
Enter your five digit code.
Turn handle to open safe.
DO NOT use rechargeable batteries or any other type of
non-alkaline battery.
3
4
Bolt-down kit contents (in select models only):
2 lag screws
2 washers
2 masonry anchors
Tools needed to bolt safe to the floor:
Drill
Wrench
7⁄16” (11 mm) drill bit – for drilling into the safe
9⁄32” (7.2 mm) drill bit – for drilling into a wood floor
3⁄8” (9.5 mm) drill bit – for drilling into a masonry floor
Warning:
• DO NOT drill from any location inside the safe.
• DO NOT bolt through the walls.
1 Tip the safe onto its right side (door hinges horizontal with the
floor).
2 Unlock the safe and open the door.
Look to the bottom of the safe for two
indentations on the feet in opposite
corners. Using the 7⁄16” (11 mm) bit;
drill a hole through each indentation
perpendicular to the bottom of the safe. DO NOT drill from any
location inside the safe.
3 Tip the safe upright, place the safe in the
desired location and open the door.
4 Use a screw or pencil to mark the floor through
both holes.
5 Move the safe aside to clear both marked spots for drilling.
6 Drill into the floor:
For wood: Using the 9⁄32” drill bit,
drill a hole 21⁄2” (64 mm) deep in
each marked spot.
For masonry: Using the 3⁄8” drill
bit, drill a hole 21⁄2” (64 mm) deep in
each marked spot. Install a masonry anchor in each hole.
7 Replace the safe in the desired position, with the holes in the
safe aligned with those in the floor.
8 Securing the safe:
For wood: Pass each lag screw through a
washer, then through the safe and into a
hole. Tighten with the wrench.
For masonry: Pass each lag screw
through a washer, then through the safe
and into a masonry anchor. Tighten with
the wrench. Place masonry anchors into
the holes in the floor.
NOTE:
The safe should not be bolted to a wall, this will
compromise the fire rating. Drill holes through the feet
only. DO NOT drill through the back or sides.
Bolting/unbolting the unit is at the consumer’s expense and
discretion.
Master Lock is not responsible for any costs incurred if the
unit is to be replaced.
Not all Master Lock products come with a bolt-down kit.
1
2
3
1
2
3
Programming Safe Features
YOUR DIGITAL LOCK
Programming the User Code (UC)
Only 1 user code can be programmed at a time.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – PROG FACTORY CODE (FC)
(found on the back of this owner’s manual).
The Program indicator light will blink.
Press the five digit user code you have chosen
for your safe.
3
Deleting a User Code
1
2
Touch the keypad to wake up the safe.
Press: “ ” – PROG FACTORY CODE (FC)
(found on the back of this owner’s manual).
The Program indicator light will blink.
Press: “ ” –“ –“ ” –“ –“ 00000
NOTE: The electronic lock will NOT indicate that it has
deleted the user code—please test code to make sure it has
been deleted.
3
4
4
Programming the Secondary Code (SC)
Only 1 user code can be programmed at a time.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “PROG PROG PROGRAMMED USER CODE (UC)
The Program indicator light will blink.
Press the five digit secondary code you have chosen for this safe.
3
4
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “PROG PROG PROGRAMMED USER CODE (UC)
The Program indicator light will blink.
Press: “ ” –“ –“ ” –“ –“ 00000
NOTE: The electronic lock will NOT indicate that it has
deleted the user code—please test code to make sure it
has been deleted.
3
4
Deleting a Secondary Code
Cleaning Your Keypad
Bolt-down instructions
Use a soft cloth or microfiber cloth to wipe the surface of your lock
to remove fingerprints.


Product specificaties

Merk: Master Lock
Categorie: Niet gecategoriseerd
Model: LFW205TWC

Heb je hulp nodig?

Als je hulp nodig hebt met Master Lock LFW205TWC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Master Lock

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd