Liberty Pumps CSP-257 Handleiding
Liberty Pumps
Pomp
CSP-257
Lees hieronder de 📖 handleiding in het Nederlandse voor Liberty Pumps CSP-257 (14 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/14
©Copyright 2011 Liberty Pumps Inc. All rights reserved
IMPORTANT:
Prior to installation, record Model, Serial Number, and
Code Number from pump nameplate for future reference.
MODEL ________________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE _____________________ __
CSP-237 1/3HP 115V 60Hz
CSP- 7 1/3HP 115V 60Hz 25
CSP-457 1/2HP 115V 60Hz
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
Contents
1.) General Information and Safety
Guidelines
2.) Installation
3.) Maintenance and Troubleshooting
Installation Manual 4353 0C00
Model CSP-237, CSP-257, and CSP-457 Crawl Space Pump
©Copyright 2011 Liberty Pumps Inc. All rights reserved -2-
Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper
performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Do not bypass grounding wires or remove ground prong from attachment plugs.
Do not use an extension cord.
This pump requires separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the a
voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to minimize
possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code and Plumbing Codes as well as all applicable local codes
and ordinances.
Fig. 1 – Typical Residential Installation
This is a recommended installation only.
1. General Information and Safety Guidelines
2. Installation
Figure 1
©Copyright 2011 Liberty Pumps Inc. All rights reserved -3-
Application: The CSP- , CSP-257, and CSP-457 crawl space pumps are designed for use a crawl space or where pooling water 237 in
is occurring. Allowing the water in the pump or discharge line to freeze may cause damage to the pump. In colder regions, the pump
should only be installed indoors or deep enough to be below the frost line.
A. For in ground installation a hole should excavated as small as possible, leaving at least 8” of diametrical clearance. BACKFILL:
Course gravel is recommended for backfill.
B. The CSP- , CSP-257, and CSP-457 include a perforated basin for gathering water. Additional inlets may be added with INLET: 237
a hole saw for allowing drain lines or weep tiles.
C. When attaching the discharge, place the pump in the basin being careful to keep float from any obstruction or from DISCHARGE:
hitting the tank wall. The CSP- , CSP-257, and CSP-457 include a DHK-24 discharge hose kit. A 1-1/2” X 1-1/4” hose adapter 237
will thread into the pump discharge. The 24’ flexible hose will fit over the barbed fitting of the adapter and should be tightened
down with a hose clamp. The hose will fit through the grommet in the basin cover and can be cut to the required length. Exit the
discharge of water in an area that will drain away from the building and foundation.
D. The CSP- , CSP- and CSP-457 include a threaded check valve for use with the discharge hose. If the CHECK VALVE: 237 257,
pump is short cycling, then a check valve may be required. This would prevent water from draining back through the discharge
hose into the basin. When using a check valve, the discharge line must be protected from freezing by running the discharge deep
enough below ground level to be beneath the frost line. See figure 1.
E. The pump power cord is equipped with a grounding conductor and grounding-type 3-prong plug. It should be POWER CORD:
connected to a separately fused, grounded, 3-wire grounding-type receptacle of 15-amp capacity with the proper . Make sure 115V
all electrical wiring and connections are in accordance with the National Electric Code and all applicable local codes.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
DO NOT remove the plug or ground prong.
DO NOT use an extension cord.
Product specificaties
Merk: | Liberty Pumps |
Categorie: | Pomp |
Model: | CSP-257 |
Heb je hulp nodig?
Als je hulp nodig hebt met Liberty Pumps CSP-257 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Liberty Pumps
30 September 2024
30 September 2024
30 September 2024
30 September 2024
5 Juli 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
4 December 2024
4 December 2024
30 November 2024
30 November 2024
23 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
18 November 2024