INSTALLATION
DATE ______________________
Β©Copyright 2015 Liberty Pumps Inc. All rights reserved
Contents
1.) General Information
2.) The Basin
3.) Installation
4.) Electrical Service and Operation
5.) Maintenance and Troubleshooting
6.) Warranty
Installation Manual 7034000L
LE and LEH Series Sewage Pumps
Models
LE40-Series 4/10 HP
LE50-Series 1/2 HP
LE70-Series 3/4 HP
LE100-Series 1 HP
LEH100-Series 1 HP
LEH150-Series 1.5 HP
LEH200-Series 2 HP
*Do not throw away or lose this manual.

Β©Copyright 2015 Liberty Pumps Inc. All rights reserved 2
Before Installation, read the following instructions carefully. Each Liberty pump is individually factory tested to assure
proper performance. By closely following these instructions, potential operating problems should be eliminated, providing
years of trouble-free service.
ο· Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
ο· The electrical connections and wiring for a pump installation should only be made by qualified personnel.
ο· This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric
shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
ο· Always wear rubber boots when water is on the floor and you must unplug the pump.
ο· DO NOT bypass grounding wires or remove ground prong from attachment plugs.
ο· DO NOT use an extension cord.
ο· This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly
sized for the voltage and amperage requirements of the pump, as noted on the nameplate.
ο· The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level
to minimize possible hazards from flood conditions .
ο· The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International
Plumbing Code, as well as all applicable local codes and ordinances.
ο· Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective
clothing when working on a used pump or piping.
ο· Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are poisonous.
ο· Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.
ο· DO NOT use this product for flammable or corrosive liquid.
ο· DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming
pools, fountains, etc.)
ο· NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and
damage pump components, potentially causing product malfunction or failure.
ο· DO NOT use pumps in water over 140ο°
ο°
ο°
ο°ο°F (60ο°
ο°
ο°
ο°ο°C).
ο· DO NOT use pumps in mud, sand, cement, oil or chemicals.
ο· DO NOT modify the pump in any way.
ο· DO NOT lift or carry pump by power cord.
ο· DO NOT remove any tags from pump or cords.
ο· If pump is installed during construction before power is available, it must be protected from the environment to prevent
water from entering through the cord plug end, etc.
Disconnect old pump from power source before handling.
Separate the discharge pipe at either the check valve or at the union. If neither a check valve nor a union is part of the
existing discharge pipe, cut the pipe with a hacksaw and remove the pump (A union or check valve will need to be
installed at this cut).
1. General Information

Β©Copyright 2015 Liberty Pumps Inc. All rights reserved 3
οͺ Note: Manual models (βMβ suffix) and 3 phase models, as designated above, require a separate approved pump control device or
panel for automatic operation. Operation of these models will be according to the control selected. Make sure the electrical
specifications of the control selected properly match the electrical specifications of the pump. 3 phase models require overload
elements selected or adjusted in accordance with the control or panel instructions.
Automatic pumps have a float switch preassembled. The optional (V) denotes that the pump is available with a vertical float.
MODEL SPECIFICATIONS
Model
HP
Volts
Phase
Full Load
Amps
Solids
Handling
FNPT
Discharge
Automatic or
Manual*
Shut-off
Head
LE41A (V)
4/10
115
1
12
2β
2β
Automatic
19β
*LE41M
4/10
115
1
12
2β
2β
Manual*
19β
LE51A (V)
1/2
115
1
12
2β
2β
Automatic
25β
*LE51M
1/2
115
1
12
2β
2β
Manual*
25β
LE52A
1/2
208-230
1
6.8
2β
2β
Automatic
25β
*LE52M
1/2
208-230
1
6.8
2β
2β
Manual*
25β
LE71A
3/4
115
1
12
2β
2β or 3β
Automatic
28β
*LE71M
3/4
115
1
12
2β
2β or 3β
Manual*
28β
LE72A
3/4
208-230
1
6
2β
2β or 3β
Automatic
28β
*LE72M
3/4
208-230
1
6
2β
2β or 3β
Manual*
28β
*LE73M
3/4
208-230
3
4.1
2β
2β or 3β
Manual*
28β
*LE74M
3/4
440-480
3
2.1
2β
2β or 3β
Manual*
28β
LE102A
1
208-230
1
8
2β
2β or 3β
Automatic
36β
*LE102M
1
208-230
1
8
2β
2β or 3β
Manual*
36β
*LE103M
1
208-230
3
5.3
2β
2β or 3β
Manual*
36β
*LE104M
1
440-480
3
2.5
2β
2β or 3β
Manual*
36β
*LE105M
1
575
3
1.9
2β
2β or 3β
Manual*
36β
NOTE: LEH -Series High-Head pumps require a minimum application of 15β head. 100
LEH102A
1
230
1
12
2β
2β or 3β
Automatic
53β
*LEH102M
1
230
1
12
2β
2β or 3β
Manual*
53β
*LEH103M
1
208-230
3
9
2β
2β or 3β
Manual*
53β
*LEH104M
1
440-480
3
4.5
2β
2β or 3β
Manual*
53β
*LEH105M
1
575
3
3.3
2β
2β or 3β
Manual*
53β
NOTE: LEH150 & LEH200 Series High-Head pumps require a minimum application of head. 20β
LEH152A
1.5
208-230
1
15
2β
2β or 3β
Automatic
70β
*LEH152M
1.5
208-230
1
15
2β
2β or 3β
Manual*
70β
*LEH153M
1.5
208-230
3
10.6
2β
2β or 3β
Manual*
70β
*LEH154M
1.5
440-480
3
5.3
2β
2β or 3β
Manual*
70β
*LEH155M
1.5
575
3
4.9
2β
2β or 3β
Manual*
70β
*LEH202M
2
230
1
18
2β
2β or 3β
Manual*
83β
*LEH203M
2
208-230
3
13.2
2β
2β or 3β
Manual*
83β
*LEH204M
2
440-480
3
6.6
2β
2β or 3β
Manual*
83β
*LEH205M
2
575
3
5.5
2β
2β or 3β
Manual*
83β
WARNING:
Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a
cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other
significant failure.
Product specificaties
Merk: | Liberty Pumps |
Categorie: | Pomp |
Model: | LE51M |
Heb je hulp nodig?
Als je hulp nodig hebt met Liberty Pumps LE51M stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Liberty Pumps

27 Maart 2025

27 Maart 2025

30 September 2024

30 September 2024

30 September 2024

30 September 2024

5 Juli 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp ZΓ©fal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025

29 Maart 2025