©Copyright 2018 Liberty Pumps Inc. All rights reserved
Installation Manual 7035000N
Heavy Duty Submersible Effluent/Dewatering Pumps
*Do not throw away or lose this manual.
Models
250- Series 1/3 HP
280- Series 1/2 HP
290- Series 3/4 HP
FL30- Series 1/3 HP
FL50- Series 1/2 HP
FLH60 Series 6/10 HP -
FL60- Series 6/10 HP
FL70- Series 3/4 HP
FL100- Series 1 HP
FL150- - Series 1 1/2 HP
FL200- Series 2 HP
Contents
ï‚· Safety Information
ï‚· General Information
ï‚· Dewatering/Sump Applications
ï‚· Effluent Applications
ï‚· Electrical Service and Operation
ï‚· Maintenance and Troubleshooting
ï‚· Warranty
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
©Copyright 2018 Liberty Pumps Inc. All rights reserved 2
1. Safety Information
This safety alert symbol in your manual and on the pump is intended to alert you
to a potential risk for injury or death.
This is a safety alert symbol identifying risk of electric shock. It will be accompa-
nied with an instruction intended to minimize your potential risk of electric shock.
This is a safety alert symbol identifying risk of fire. It will be accompanied with an
instruction intended to minimize your potential risk of fire.
This is a safety alert symbol identifying risk of injury or death. It will be accompa-
nied with an instruction intended to minimize your potential risk of injury or death.
Warns of hazards that will cause serious injury or death.
Warns of hazards that can or will cause minor or moderate injury.
Warns of hazards that can cause personal injury, death, or property damage.
Signals an important instruction related to the pump. Failure to follow these in-
structions could result in pump component failure, or improper operation of the
unit, possibly resulting in property damage .
NOTICE
DANGER
WARNING
CAUTION
ï‚· ALWAYS disconnect the supplied pump(s) from their power sources before handling or making any adjustments to
either the pump(s), the pump system, or the control panel.
ï‚· Only qualified personnel should complete fixed wiring and electrical connections, according to all local and national
electrical codes, during a pump system installation.
ï‚· After installation, be certain that the pump is properly grounded, using its supplied grounding conductor. Failure to
properly ground the pump system can cause all metal portions of the pump and its surroundings to become ener-
gized.
ï‚· During flood conditions, submerged electrical connections can energize the water. Always wear dielectric rubber
boots and other applicable Personal Protective Equipment (PPE) when water is on the floor and you must service an
energized pump system. DO NOT ENTER THE WATER if the water level is higher than that of the protection your
PPE offers or if your PPE is not watertight.
ï‚· NEVER lift or carry a pump or a float assembly by its power cord. This will damage the power cord, and could ex-
pose the electrically live wires inside the power cord.
ï‚· DO NOT bypass grounding wires.
ï‚· The electrical power supply shall be located within the length limitations of the pump power cord, and for below
grade installations it shall be at least 1.22 m (4 ft) above the floor level.
ï‚· NEVER use this product in applications where human contact with the pumped fluid is common (such as swimming
pools, fountains, marine areas, etc.).
RISK OF ELECTRIC SHOCK - Accidental contact with
electrically live parts, items, fluid, or water can cause serious in-
jury or death.
WARNING
©Copyright 2018 Liberty Pumps Inc. All rights reserved 3
ï‚· During construction, if the pump system is installed before its power cord can be plugged in or direct wired, all power
cords must be protected from the environment to prevent water from wicking through the cord end into the pump or
switch housings. If water enters these housings, an electrical short can occur from the pump or switch to its sur-
roundings, which will energize the surroundings.
ï‚· DO NOT use an extension cord to power the product. Extension cords can overload both the product and extension
cord supply wires. Overloaded wires will get very hot and can catch on fire.
ï‚· This product requires a separate, properly fused and grounded branch circuit, sized for the voltage and amperage
requirements of the pump, as noted on the nameplate. Overloaded branch circuit wires will get very hot and can
catch on fire.
ï‚· NEVER use this product with or near flammable liquids. If the rotating elements inside this pump strike any foreign
object, sparks may occur. Sparks could ignite flammable liquids.
ï‚· This pump system must be installed in accordance with all applicable codes and ordinances.
ï‚· DO NOT allow children to play with the pump system.
ï‚· DO NOT allow children, or any person who is unqualified, to use this pump system. Any person who is unaware of
the dangers of this pump system, or whom has not read this manual, can easily be injured by the pump system.
ï‚· Wear adequate PPE when working on pumps or piping that have been exposed to wastewater. Sump and sewage
pumps often handle materials which can transmit illness or disease upon contact with your skin and other tissues.
ï‚· DO NOT remove any tags or labels from the pump or its cord.
NOTICE
RISK OF ELECTRIC SHOCK -cont inued
WARNING
RISK OF FIRE
WARNING
WARNING
RISK OF SERIOUS INJURY OR DEATH
ï‚· NEVER dispose of materials such as paint thinner or other chemicals down drains. Doing so could chemically attack
and damage pump system components and cause product malfunction or failure.
 DO NOT use pumps with fluid over 40°C. Operating the pump in fluid above this temperature can overheat the
pump, resulting in pump failure.
ï‚· DO NOT use pump system with mud, sand, cement, oil or chemicals. Pump and system components can be dam-
aged from these items causing product malfunction or failure. Additionally, flooding can occur if these items jam the
impeller or piping.
ï‚· DO NOT modify the pump system in any way. Modifications may affect seals, change the electrical loading of the
pump, or damage the pump and its components. Modifications can void your warranty on this product.
ï‚· DO NOT run this pump system dry.
Product specificaties
Merk: | Liberty Pumps |
Categorie: | Pomp |
Model: | 250 |
Heb je hulp nodig?
Als je hulp nodig hebt met Liberty Pumps 250 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Liberty Pumps
30 September 2024
30 September 2024
30 September 2024
30 September 2024
5 Juli 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
13 November 2024
12 November 2024
12 November 2024
11 November 2024
5 November 2024
5 November 2024
4 November 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024