Liberty Pumps 230 Handleiding
Liberty Pumps
Pomp
230
Lees hieronder de đź“– handleiding in het Nederlandse voor Liberty Pumps 230 (18 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/18
©Copyright 2013 Liberty Pumps Inc. All rights reserved
*Do not throw away or lose this manual. Keep it with the installation and refer to it often.
Submersible Models 1/4 hp
-Series…Cast Iron 240
240 Manual
241 Wide Angle Float
243 Wide-Angle Float w/Series Plug
247 Vertical Float
Submersible Models 1/3 hp
230-Series…Poly/Aluminum
230 Manual
231 Wide Angle Float
233 Wide-Angle Float w/series plug
237 Vertical Float
Submersible Models 1/2 hp
450-Series…Poly/Aluminum
450 Manual
451 Wide Angle Float
453 Wide-Angle Float w/series plug
457 Vertical Float
Installation Manual 7108000I
For Submersible Sump Pumps
IMPORTANT:
Prior to installation, record Model, Serial Number, and Code
Number from pump nameplate for future reference.
MODEL ______________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE ______________________
©Copyright 2013 Liberty Pumps Inc. All rights reserved - 2 -
1. General Information – All Models
Before Installation, read the following instructions carefully. Each Liberty pump is individually factory tested to assure
proper performance. By closely following these instructions, potential operating problems should be eliminated,
providing years of trouble-free service.
ď‚· Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
ď‚· The electrical connections and wiring for a pump installation should only be made by qualified personnel.
ď‚· This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric
shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
ď‚· Always wear rubber boots when water is on the floor and you must unplug the pump.
ď‚· DO NOT bypass grounding wires or remove ground prong from attachment plugs.
ď‚· DO NOT use an extension cord.
ď‚· This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly
sized for the voltage and amperage requirements of the pump, as noted on the nameplate.
ď‚· The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level
to minimize possible hazards from flood conditions.
ď‚· The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International
Plumbing Code, as well as all applicable local codes and ordinances.
ď‚· Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective
clothing when working on a used pump or piping.
ď‚· Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are poisonous.
ď‚· Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.
ď‚· DO NOT use this product for flammable or corrosive liquid.
ď‚· DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming
pools, fountains, etc.)
ď‚· NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and
damage pump components, potentially causing product malfunction or failure.
ď‚· DO NOT use pumps in water over 140ď‚°
ď‚°
ď‚°
ď‚°ď‚°F (60ď‚°
ď‚°
ď‚°
ď‚°ď‚°C).
ď‚· DO NOT use pumps in mud, sand, cement, oil or chemicals.
ď‚· DO NOT modify the pump in any way.
ď‚· DO NOT lift or carry pump by power cord.
ď‚· DO NOT remove any tags from pump or cords.
ď‚· If pump is installed during construction before power is available, it must be protected from the environment to prevent
water from entering through the cord plug end, etc.
Tools Required:
- Pipe wrench
- Regular screw driver
- Hacksaw (For replacement or removal of existing rigid piping.)
©Copyright 2013 Liberty Pumps Inc. All rights reserved - 3 -
2. Sump Pit – All Models
1. A sump pit not less than 14” in diameter is recommended. On submersible pumps equipped with the vertical float
(models 237 and 247), a minimum 10” diameter pit is acceptable. A larger diameter pit is preferred as it allows for
longer pump cycling and reduced switch cycling. The depth of the pit should be at least 12” above the surface
that the pump is resting on.
2. If the pit is not already enclosed on the bottom, provide a hard level bottom of bricks or concrete. DO NOT place
the pump directly on earth, gravel or debris since this can cause excessive wear of the impeller and possible
jamming. (sold by Liberty Pumps as part # 4445000) is a pre-molded stable platform designed to fi“The Brick” t
your submersible pump. It raises the pump 2.5” off the bottom of the pit, reducing the potential for jamming from
rocks and debris. Contact your local distributor to order. Remove all debris from the bottom of the sump pit
before installation of the pump. A sump pit cover is suggested for safety and to prevent foreign objects from
entering the pit.
3. Installation of Pump – All Models
1. Removal of Old Pump:
Disconnect pump from power source before handling.
Separate the discharge pipe at either the check valve or at the union. If neither a check valve nor a union is part
of the existing discharge pipe, cut the pipe with a hacksaw and remove the pump (A union or check valve will
need to be installed at this cut).
2. Set the new pump in place making sure the float switch has adequate clearance and will not hang-up on the pit
wall. The float must be and not contacting the pump body, piping, or other free to move throughout its travel
objects.
3. 1-1/2” threaded discharge is provided on the pump for nnection to the discharge pipe. Do not reduce the A co
discharge size to less than 1-1/4”, as this will affect pump flow and performance. Schedule 40 PVC pipe is
recommended; however, flexible discharge hose kits may be used for temporary installations.
4. nnect the pipe or the discharge hose to the discharge of the pump. HAND TIGHTEN ONLY. Overtightening Co
may cause the pump housing to crack.
5. Install a union or other means of separating the discharge pipe just above the floor to facilitate removal of the
pump if necessary. A check valve is recommended just above or in place of the union to prevent the
backflow of water after each pump cycle.
6. If a check valve is used, a 1/8” anti-airlock hole should be drilled in the discharge pipe just above the
pump’s discharge outlet to prevent pump “airlock”. Refer to Figure B.
Product specificaties
Merk: | Liberty Pumps |
Categorie: | Pomp |
Model: | 230 |
Heb je hulp nodig?
Als je hulp nodig hebt met Liberty Pumps 230 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Liberty Pumps
30 September 2024
30 September 2024
30 September 2024
30 September 2024
5 Juli 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp ZĂ©fal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
13 November 2024
12 November 2024
12 November 2024
11 November 2024
5 November 2024
5 November 2024
4 November 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024