INSTRUCTION MANUAL
MODEL 8128
POWER CLAMP SENSOR
Series
POWER CLAMP SENSOR
1. Safety warnings
β—‹ This instrument has been designed, manufactured and
tested according to IEC 61010: Safety requirements
for Electronic Measuring apparatus, and delivered in
the best condition after passing quality control tests.
This instruction manual contains warnings and safety
rules which have to be observed by the user to ensure
safe operation of the instrument and to maintain it in
safe condition. Therefore, read through these operating
instructions before using the instrument.
# WARNING
● Read through and understand instructions contained
in this manual before using the instrument.
● Keep the manual at hand to enable quick reference
whenever necessary.
● The instrument is to be used only in its intended
applications.
γ€€ The operating instructions described in the manual
must be observed.
● Understand and follow all the safety instructions
contained in the manual. It is essential that the
above instructions are adhered to. Failure to follow
the above instructions may cause injury and or
instrument damage.
Kyoritsu is by no means liable for any damage
resulting from the instrument in contradiction to this
cautionary note.
β—‹ The symbol indicated on the instrument, means that #
the user must refer to the related parts in the manual
for safe operation of the instrument. It is essential to
read the instructions wherever the symbol appears #
in the manual.
# DANGERγ€€ is reserved for conditions and actions
that are likely to cause serious or
fatal injury.
# γ€€ is reserved for conditions and actions WARNING
that can cause serious or fatal Injury.
# CAUTIONγ€€ is reserved for conditions and actions
that can cause minor injury or
instrument damage.
# DANGER
● Never make measurement on a circuit in which the
electrical potential exceeds AC300V.
● Do not make measurement when thunder rumbling. If
the instrument is in use, stop the measurement
immediately and remove the instrument from the
measured object.
● Do not attempt to make measurement in the
presence of flammable gasses. Otherwise, the use
of the instrument may cause sparking, which can
lead to an explosion.
● The transformer jaws are made of metal and their
tips are not completely insulated. Be especially
careful about the possible shorting where the
measured object has exposed metal parts.
● Never attempt to use the instrument if it's surface or
your hand are wet.
● Do not exceed the maximum allowable input of any
measuring range.
● Use insulated protective gears, such as insulated
gloves, for your safety when possible electric shock
hazards are concerned.
● Keep your fingers and hands behind the barrier
during a measurement.
# WARNING
● Never attempt to make any measurement, if any
abnormal conditions are noted, such as broken
case, and exposed metal parts.
● Do not install substitute parts or make any
modification to the instrument. Return the
instrument to the distributor from who you
purchased this instrument for repair or re-calibration
in case of suspected faulty operation.
● Always keep your fingers and hands behind the
barrier on the instrument to avoid the possible
shock hazard.
# CAUTION
● Do not step on or pinch the cord to prevent the
jacket of cable from being damaged.
● The output connector shall be removed or
connected without clamping a conductor.
Otherwise, it may cause a failure.
● Do not expose the instrument to direct sunlight,
high temperatures, humidity or dew.
● Never give shocks, such as vibration or drop, which
may damage the instrument.
● Use a damp cloth and detergent for cleaning the
instrument. Do not use abrasives or solvents.
Safety symbols
#Refer to the instructions in the manual.
ο€±Indicates a Instrument with double or reinforced
insulation
Indicates that this instrument can clamp on bare
conductors.
γ€œIndicates AC
β—‹Measurement categories(Over-voltage categories)
To ensure safe operation of measuring instruments, IEC
61010 establishes safety standards for various electrical
environments, categorized as o to CAT IV, and called
measurement categories. Higher-numbered categories
correspond to electrical environments with greater
momentary energy. So a measuring instrument designed for
CAT III enviroments can endure greater momentary energy
than one desined for CAT II.
γ€€O(None, Other): Circuits which are not directly
connected to the mains power supply.
γ€€CAT β…‘: Primary electrical circuits of equipment
connected to an AC electrical outlet by a
power cord.
γ€€CAT β…’: Primary electrical circuits of the equipment
connected directly to the distribution panel,
and feeders from the distribution panel to
outlets.
γ€€CAT β…£: The circuit from the service drop to the
service entrance, and to the power meter and
primary overcurrent protection device
(distribution panel).
O: Device which is
not directly
connected to the
mains power supply
2. Features
●This is a clamp sensor for our Power meter.
● Designed to international safety standard
IEC 61010-2-032
CAT β…’ 300V (Pollution Degree 2)
3. Instrument layout
Transform Jaws
Barrier
Trigger
Cable
Output connector
Barrier : It is a part providing protection against electrical
shock and ensuring the minimum required air and
creepage distances.
4. Din plug pin assignment
3: GND pin
5: Output signal pin
6: Sensor signal pin
(Resistance between 3Pin
and 6Pin : 91kΞ©οΌ‰
1, 2 and 4: No use
* Above figure shows the pin assignment seeing the Clamp
sensor from output connector part. The figure of the pin
assignment of connection terminal is symmetrical to above
figure.
5
3
12
4
6
5. Specifications
Model 8128
Rated voltage AC5A
Output voltage 10mV/A (AC 50mV/AC 5A)
(AC500mV/AC50A)
Measuring range
AC0 γ€œ 50Arms(70.7Apeak)
Accuracy
(Input: sine wave)
Β± 0.5%rdg Β± 0.1mV (50/60Hz)
Β± 1.0%rdg Β± 0.2mV (40 γ€œ 1kHz)
Phase
characteristics Β± 2deg within(at 0.5 γ€œ 50A / 45 γ€œ 65Hz)
Temperature & humidity range
(Guaranteed accuracy)
23 Β± 5℃, relative humidity: 85% or less (no condensation)
Operating temperature range
0 γ€œ 50℃ , relative humidity: 85% or less (no condensation)
Storage temperature range
-20 γ€œ 60℃ , relative humidity: 85% or less (no condensation)
Maximum permissible input
AC50Arms continuous(50/60Hz)
Output
impedance Approx. 19 Ξ©
Location for use Altitude up to 2000m, Indoors
Applicable
standards
IEC 61010-1, IEC 61010-2-032
Measurement CAT III (300Vrms)
Pollution degree 2
IEC 61326-1 (EMC)
Environmental
standards EU RoHS Directive compliant
Withstand
voltage
AC3540Vrms (50/60Hz) for 5 sec.
between Jaw and enclosure
between enclosure and output terminal
between Jaw and output terminal
Insulation
resistance
50M Ξ© or greater at 1000V
between Jaw and enclosure
between enclosure and output terminal
between Jaw and output terminal
Conductor Size Approx.24mm in diameter (max.)
Dimension 100 x 60 x 26mm
Cable length Approx. 3m
Output terminal MINI DIN 6PIN
Weight Approx. 160g
Accessories Cable marker
Instruction manual
Accessories MODEL 7146 (Banana F4 adjuster plug)
MODEL 7185 (Extension cable)
6. Operating instructions
# DANGER
● Never make measurement on a circuit in which the
electrical potential exceeds AC300V in order to avoid
possible shock hazard.
● The transformer jaws are made of metal and their tips
are not completely insulated. Be especially careful
about the possible shorting where the measured object
has exposed metal parts.
# CAUTION
● Take sufficient care to avoid shock, vibration or
excessive force when handling the instrument.
Otherwise, precisely adjusted transformer jaws
will be damaged.
● When transformer jaws do not fully close, never try
to close them by force, but make them free to move
and try again. If a foreign substance is stuck in
the jaw tips, remove it.
● When making current measurements, keep the
transformer jaws fully closed.
γ€€ Otherwise, accurate measurements cannot be
taken. Maximum conductor size is 24mm in
diameter.
● Hold the inserting part (except for the cable) and
disconnect the Output connector from the
measuring instrument so as not to cause a break in
the cable.
6-1 Measurement procedures
(1) Connect the Output connector to the Input terminal of
the measuring instrument.
(2) Press the Trigger to open the transformer jaws and
clamp onto one conductor. In this case, the measured
conductor shall be at the center of the jaws.
When connecting a sensor with a Power meter (our
Power meter, MODEL6300, etc.) match the arrow
mark (Power source to load), which is indicated on
the transformer jaws, with the current flowing
direction in 0order to synchronize the phases of
measured current and output voltage.
(3) Ensure that the tips of transformer jaws are firmly
closed.
Conductor
Load
Current direction
arrow
Power
source
6-2 Setting for MODEL6300 Power meter
(MODEL 6300 is a discontinued product.)
Refer to the table below when using these clamp sensors
with MODEL6300, It shows the settings for clamp sensor
and available current ranges on MODEL6300.
For further details on the settings, see the instruction
manual for MODEL6300.
MODEL
Setting for MODEL6300
Type of
Clamp sensor Current range
MODEL8128 50A 5 / 10 / 20 / 50A
This instrument satisfies the marking requirement
defined in the WEEE Directive (2002/96/EC).
This symbol indicates separate collection for
electrical and electronic equipment.
92
-
1800C5-22
DISTRIBUTOR
Kyoritsu reserves the rights to change specifications or designs
described in this manual without notice and without obligations.


Product specificaties

Merk: Kyoritsu
Categorie: Meetapparatuur
Model: 8128

Heb je hulp nodig?

Als je hulp nodig hebt met Kyoritsu 8128 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Kyoritsu

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur