Gossen Metrawatt PROFITEST REMOTE Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Gossen Metrawatt PROFITEST REMOTE (16 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 4 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Operating Instructions
PROFITEST REMOTE
3-Phase Test Adapter for Testers Including
PROFITEST MTECH+ IQ, MXTRA IQ and PRIME 3-447-051-15
4/6.22
Important
Read carefully before use!
Keep on file for future reference!
2 Gossen Metrawatt GmbH
Connections Overview
Meanings of Symbols on the Instrument
300 V CAT III
Maximum permissible voltage and
measuring category between con-
nections and ground
Warning concerning a point of
danger (attention: observe docu-
mentation!)
Indicates European Conformity
This device may not be disposed
of with household trash, see
“Returns and Environmentally
Sound Disposal” on page 15.
Scope of Delivery
1 Test adapter (M514R)
1 RS 232 interface cable, type Z3241
1 Set of operating instructions
Allocation of fuses
Measurement Input
Conductor LEDs indicate
conductor continuity
Location of Fuses
- PRO-SCHUKO plug insert
for PROFITEST MTECH+ IQ
RS 232 port
!Max. 500 V
for Mains Connection
and MXTRA IQ
- Three 4 mm safety sockets
for PROFITEST PRIME
for test adapter controller
Five 4 mm safety
sockets for mains/system
connection
and power supply
!
PROFITESTREMOTE Connections Overview – Symbols – Scope of Delivery
Gossen Metrawatt GmbH 3
Table of Contents Page
1 Safety Precautions .....................................3
2 Applications ...............................................5
3 Initial Startup .............................................6
3.1 Testing the LEDs ..........................................6
3.2 Connecting the Test Instrument to the Test
Adapter .......................................................6
3.3 Connection to the System or the Mains .........6
3.4 Key and Significance of the LEDs ..................7
4 Measurements ...........................................8
4.1 Measuring Insulation Resistance (RISO) ..........8
4.1.1 Measuring Insulation Resistance with the PROFITEST
MTECH+ IQ or PROFITEST MXTRA IQ .................... 8
4.1.2 Measuring Insulation Resistance with the
PROFITEST PRIME ................................................ 9
4.2
Measuring Loop Impedance (
Z -L PE
) ................ 10
4.2.1 Measuring Loop Resistance with the PROFITEST
MTECH+ IQ or PROFITEST MXTRA IQ .................. 10
4.2.2
Measuring Loop Impedance with the
PROFITEST PRIME
................................................. 10
4.3 Measuring Line Impedance (ZL N- ) ...............11
4.3.1 Measuring Line Impedance with the PROFITEST
MTECH+ IQ and PROFITEST MXTRA IQ ................ 11
4.3.2 Measuring Line Impedance with the
PROFITEST PRIME .............................................. 12
4.4 Error Messages at the Test Instrument ........13
5 Characteristic Values ...............................14
6 Maintenance ............................................15
6.1 Housing Maintenance .................................15
6.2 Technical Safety Inspections,
Testing per DGUV Regulation 3 ...................15
6.2.1
Testing Protective Conductor Resistance .......................15
6.2.2 Testing Insulation Resistance .............................. 15
6.3 Fuse Replacement .....................................15
6.4 Returns and Environmentally Sound
Disposal ....................................................15
7 Contact, Support and Service ..................16
1 Safety Precautions
The test adapter has been manufactured
and tested in accordance with the following
safety regulations:
I
EC/EN 61010-1/VDE 0411-1,
DIN EN 61326-1/VDE 0843-20-1
Safety of the operator, as well as that of the
test adapter, is only assured when it’s used
for its intended purpose.
Use for intended purpose stipulates applica-
tion for loop and line impedance measure-
ment ZL-PE and ZL-N as well as insulation
resistance measurement RISO exclusively in
combination with the
–PROFITEST MTECH+ IQ, as of FW V03.04.04
–PROFITEST MXTRA IQ, as of FW V03.04.04
–PROFITEST PRIME, as of FW V03.05.00
test instruments. Any other application (e.g.
voltage measurement or use in combination
with other test instruments) are not permissi-
ble.
Read the operating instructions carefully and
completely before placing your test instrument
into service. Follow all instructions contained
therein. Make sure that the operating instructions
are available to all users of the device.
Read the operating instructions for the respective
test instrument as well, in particular the sections
concerning the measurement of insulation, loop
and internal line resistance.
Tests may only be performed by a qualified elec-
trician, or under the supervision and direction of a
qualified electrician. The user must be instructed
by a qualified electrician concerning performance
and evaluation of the test (see also training semi-
nars listed at www.gossenmetrawatt.com).
PROFITESTREMOTE Table of Contents – Safety Precautions


Product specificaties

Merk: Gossen Metrawatt
Categorie: Niet gecategoriseerd
Model: PROFITEST REMOTE

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt PROFITEST REMOTE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Gossen Metrawatt

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd