FSP/Fortron Knight KN-1101TS Handleiding

FSP/Fortron UPS Knight KN-1101TS

Lees hieronder de 📖 handleiding in het Nederlandse voor FSP/Fortron Knight KN-1101TS (18 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/18
1K/2K/3K Online UPS
Uninterruptible Power Supply System
User Manual
Table of Contents
1. Important Safety Warning ............................................................................................... 1
1-1. Transportation ..................................................................................................... 1
1- Preparation 2. ......................................................................................................... 1
1-3. Installation .......................................................................................................... 1
1-4. Operation ............................................................................................................ 1
1-5. Maintenance, service and faults ............................................................................ 2
2. Installation and setup ..................................................................................................... 3
2-1. Rear panel view ................................................................................................... 3
2-2. Setup the UPS ..................................................................................................... 4
3. Operations ..................................................................................................................... 6
3-1. Button operation .................................................................................................. 6
3-2. LCD Panel ........................................................................................................... 6
3-3. Audible Alarm ...................................................................................................... 8
3-4. LCD display wordings index .................................................................................. 8
3-5. UPS Setting ......................................................................................................... 8
3-6. Operating Mode Description ............................................................................... 11
3-7. Faults Reference Code ........................................................................................ 11
3-8. Warning indicator .............................................................................................. 12
4. Troubleshooting ............................................................................................................ 13
5. Storage and Maintenance .............................................................................................. 15
6. Specifications ............................................................................................................... 16
1
1. Important Safety Warning
Please comply with all warnings and operating instructions in this manual strictly. Save this
manual properly and read carefully the following instructions before installing the unit. Do not
operate this unit before reading through all safety information and operating instructions
carefully
1-1. Transportation
Please transport the UPS system only in the original package to protect against shock
and impact.
1-2. Preparation
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please
allow at least two hours for the UPS system to acclimate the environment.
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct sunlight or near
heater.
Do not block ventilation holes in the UPS housing.
1-3. Installation
Do not connect appliances or devices which would overload the UPS system (e.g. laser
printers) to the UPS output sockets.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be easily
accessible and close to the UPS system.
Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your
computer) to connect the UPS system to the building wiring outlet (shockproof outlet).
Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS
system.
When installing the equipment, it should ensure that the sum of the leakage current of
the UPS and the connected devices does not exceed 3.5mA.
1-4. Operation
Do not disconnect the mains cable on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective
earthing of the UPS system and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS output
sockets or output terminals block may be electrically live even if the UPS system is not
connected to the building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to
disconnect the mains.
Prevent no fluids or other foreign objects from inside of the UPS system.


Product specificaties

Merk: FSP/Fortron
Categorie: UPS
Model: Knight KN-1101TS
Kleur van het product: Zwart
Gewicht: 13000 g
Breedte: 145 mm
Diepte: 397 mm
Hoogte: 220 mm
Geluidsniveau: 50 dB
LED-indicatoren: Ja
Vormfactor: Tower
Accu/Batterij voltage: 12 V
Ondersteund aantal accu's/batterijen: 3
Certificering: IEC 62040-1\r\nIEC-62040-2\r\nCE
Geluidsalarm(en): Ja
Uitgangsvermogen: 800 W
Batterij capaciteit: 1 Ah
Accu/Batterij oplaadtijd: 4 uur
Frequentie: 47/63 Hz
Power factor: 0.99
Type koeling: Actief
Stekker: C14 stekker
Efficientie: 87 procent
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 20 - 90 procent
Type beeldscherm: LCD
Aantal AC uitgangen: 4 AC-uitgang(en)
Stopcontacttypes: C13 stekker
Output power capacity: 1 kVA
Ingang operation voltage (min): 110 V
Ingang operation voltage (max): 300 V
Uitgang operation voltage (min): 208 V
Uitgang operation voltage (max): 240 V
Crest factor: 3:1
Aantal input fases: 1
Typische backup tijd op halve lading: - min
Typische backup tijd op volledige lading: - min
Output voltage THD: 2 procent
Uitgangsspanningsregeling: 1 procent
Golfvorm: Sinus
Output vermogensfactor: 0.8