FSP/Fortron Knight KN-1101TS Handleiding
FSP/Fortron
UPS
Knight KN-1101TS
Lees hieronder de 📖 handleiding in het Nederlandse voor FSP/Fortron Knight KN-1101TS (18 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/18
1K/2K/3K Online UPS
Uninterruptible Power Supply System
User Manual
Table of Contents
1. Important Safety Warning ............................................................................................... 1
1-1. Transportation ..................................................................................................... 1
1- Preparation 2. ......................................................................................................... 1
1-3. Installation .......................................................................................................... 1
1-4. Operation ............................................................................................................ 1
1-5. Maintenance, service and faults ............................................................................ 2
2. Installation and setup ..................................................................................................... 3
2-1. Rear panel view ................................................................................................... 3
2-2. Setup the UPS ..................................................................................................... 4
3. Operations ..................................................................................................................... 6
3-1. Button operation .................................................................................................. 6
3-2. LCD Panel ........................................................................................................... 6
3-3. Audible Alarm ...................................................................................................... 8
3-4. LCD display wordings index .................................................................................. 8
3-5. UPS Setting ......................................................................................................... 8
3-6. Operating Mode Description ............................................................................... 11
3-7. Faults Reference Code ........................................................................................ 11
3-8. Warning indicator .............................................................................................. 12
4. Troubleshooting ............................................................................................................ 13
5. Storage and Maintenance .............................................................................................. 15
6. Specifications ............................................................................................................... 16
1
1. Important Safety Warning
Please comply with all warnings and operating instructions in this manual strictly. Save this
manual properly and read carefully the following instructions before installing the unit. Do not
operate this unit before reading through all safety information and operating instructions
carefully
1-1. Transportation
Please transport the UPS system only in the original package to protect against shock
and impact.
1-2. Preparation
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please
allow at least two hours for the UPS system to acclimate the environment.
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct sunlight or near
heater.
Do not block ventilation holes in the UPS housing.
1-3. Installation
Do not connect appliances or devices which would overload the UPS system (e.g. laser
printers) to the UPS output sockets.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be easily
accessible and close to the UPS system.
Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your
computer) to connect the UPS system to the building wiring outlet (shockproof outlet).
Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS
system.
When installing the equipment, it should ensure that the sum of the leakage current of
the UPS and the connected devices does not exceed 3.5mA.
1-4. Operation
Do not disconnect the mains cable on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective
earthing of the UPS system and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS output
sockets or output terminals block may be electrically live even if the UPS system is not
connected to the building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to
disconnect the mains.
Prevent no fluids or other foreign objects from inside of the UPS system.
Product specificaties
Merk: | FSP/Fortron |
Categorie: | UPS |
Model: | Knight KN-1101TS |
Kleur van het product: | Zwart |
Gewicht: | 13000 g |
Breedte: | 145 mm |
Diepte: | 397 mm |
Hoogte: | 220 mm |
Geluidsniveau: | 50 dB |
LED-indicatoren: | Ja |
Vormfactor: | Tower |
Accu/Batterij voltage: | 12 V |
Ondersteund aantal accu's/batterijen: | 3 |
Certificering: | IEC 62040-1\r\nIEC-62040-2\r\nCE |
Geluidsalarm(en): | Ja |
Uitgangsvermogen: | 800 W |
Batterij capaciteit: | 1 Ah |
Accu/Batterij oplaadtijd: | 4 uur |
Frequentie: | 47/63 Hz |
Power factor: | 0.99 |
Type koeling: | Actief |
Stekker: | C14 stekker |
Efficientie: | 87 procent |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 20 - 90 procent |
Type beeldscherm: | LCD |
Aantal AC uitgangen: | 4 AC-uitgang(en) |
Stopcontacttypes: | C13 stekker |
Output power capacity: | 1 kVA |
Ingang operation voltage (min): | 110 V |
Ingang operation voltage (max): | 300 V |
Uitgang operation voltage (min): | 208 V |
Uitgang operation voltage (max): | 240 V |
Crest factor: | 3:1 |
Aantal input fases: | 1 |
Typische backup tijd op halve lading: | - min |
Typische backup tijd op volledige lading: | - min |
Output voltage THD: | 2 procent |
Uitgangsspanningsregeling: | 1 procent |
Golfvorm: | Sinus |
Output vermogensfactor: | 0.8 |
Heb je hulp nodig?
Als je hulp nodig hebt met FSP/Fortron Knight KN-1101TS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS FSP/Fortron
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024