Professional On-Line & Line-Interactive UPS Solutions
True Double Conversion 1.0kVA - 20kVA & 30kVA - 800kVA
Output Power Factor 0.9 - Rack/Tower 2 in 1 Design - LCD Display - Perfect Battery Pack
Knight Series Online Rack UPS System
3.0/6.0kVA LCD Display– 1-P In / 1-P Out
with battery bank solution
Knight 3.0 kVA Rack specially designed to with stand high fluctuation power. Built-in input OVCD, it becomes a rugged UPS to protect your equipment against extreme
high voltage.
Knight 6.0 kVA Rack is a high flexibility UPS with 2-in-1 design which integrates standard backup UPS and long-run UPS into one unit by simply adjusting charging current
via LCD front panel. This high flexibility UPS offers easy-adjustable battery numbers design for diverse applications
Features & Advantages
●
●
●
●
●
●
●
●
●
●
●
True double-conversion
Microprocessor control optimizes reliability
Input power factor correction
Output power factor 0.8
Adjustable charge current suitable for long backup tme
Wide input voltage (110 V – 300 V)
Converter mode available
ECO mode for energy saving
Generator compatible
Smart SNMP works well with either USB or RS-232 together
display allows easy monitoring and access of UPS status
UPS Warranty: 3 years – Battery Bank Warranty: 2 years
Knight 3kVA Knight 3kVA rear view Knight 6kVA Knight 6kVA rear view
Battery Bank for Knight Rack Series 3.0 kVA UPS
Battery bank Battery Type Batteries Bank Capacity Dimension
BB-72/9RT 12V/9Ah 6 pcs 72V / 9Ah 600 x 438 x 88 mm
BB-72/18RT 12V/9Ah 12 pcs 72V / 18Ah 600 x 438 x 88 mm
Backup Time: Please see the following Backup Time Table
Battery Bank for Knight Rack Series 6.0 kVA UPS
Battery bank Battery Type Batteries Bank Capacity Dimension
BB-240/9RT 12V/9Ah 20 pcs 240V / 9Ah 580 x 438 x 133 mm
Backup Time: Please see the following Backup Time Table
Backup Time Table for Knight Series 3.0/6.0 kVA UPS
Backup Time (min)
UPS Battery Bank 100% 75% 50%
Knight
KN-1103RL
Rack
3.0 kVA
without Internal Battery 0 0 0
+ 1 BB-72/9RT - 72V / 9 Ah 5 8,3 12,5
+ 1 BB-72/18RT - 72V / 18 Ah 10 18 27
+ 2 BB-72/18RT - 72V / 36 Ah 23 38 56
+ 3 BB-72/18RT - 72V / 54 Ah 35 57 85
+ 4 BB-72/18RT - 72V / 72 Ah 46 76 113
Knight
KN-1106RL
Rack
6.0 kVA
without Internal Battery 0 0 -
+ 1 BB-240/9RT - 240V / 9 Ah 8 19 -
+ 2 BB-240/9RT - 240V / 18 Ah 37 46 -
+ 3 BB-240/9RT - 240V / 27 Ah 49 56 -
+ 4 BB-240/9RT - 240V / 36 Ah 79 84 -
P Model kVA Form Datasheet Brochure Manual SNMP Card Software Price
1 KN-1103RL 3.0 kVA Rack PDF PDF PDF Go to SNMP Go to Software Pricelist
2 KN-1106RL 6.0 kVA Rack
Specification
Model KN-1103RL KN-1106RL
Input
Capacity 3.0 kVA / 2,4 kW 6.0 kVA / 4,8 kW
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC ± 1% 110-300 VAC ± 1% @50% Load
176-300VAC ± 1% @100% Load
Frequency Range
40Hz ~ 70 Hz 46Hz ~ 54Hz or 56Hz ~ 64 Hz
Phase Single phase with ground
Power Factor ≧ 0.99 @ Nominal Voltage (Full load)
Output
Output Voltage 200/208/220/230/240VAC
Voltage Regulation ± 3% ± 1%
Frequency range
(Synchronized Range) 47~ 53Hz or 57 ~ 63Hz 46~ 54Hz or 56 ~ 64Hz
Frequency Range
(Batt. Mode) 50Hz ± 0.25Hz or 60Hz ± 0. Hz 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Overload
100%~110%:audible warning
110%~130%: UPS shut down in 30 seconds at battery mode
or transfer to bypass when the utility is normal
>130%:UPS shuts down immediately at battery mode or
transfer to bypass mode when the utility is normal 3:1 ( Max)
-
Current Crest Ratio 3:1 (Max)
Harmonic Distortion ≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Transfer Time Bypass to Inverte Zero
Inverter to Bypass 4 ms (Typical) Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
AC Mode 90% 89%
Battery Mode 89% 88%
Battery
Standard
Backup
Battery Type Depending on the capacity of external battery bank
Numbers 72V (6x 12V) 240V (20x 12V)
Typical Recharge
Time Depending on the capacity of external battery bank
Charging Current
(max.) 1.0/2.0/4.0/6.0A ± 10% 4.0/6.0A ± 10%
Charging Voltage 82.1 VDC ± 1% 8273.1 VDC ± 1%
Indicators
LCD or LED Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
AC Input & Output Connectors
AC Input Connerctos 1x IEC 320 C20 Terminal
AC Output Connerctos 4 x IEC 320 C13 Terminal
Standards
IEC 62040-1 (safety) Yes
IEC-62040-2 (EMC) Yes
CE Yes
Physical dimensions
Standard
Model
Dimension (mm) 480 (D) x 438 (W) x 88 (H) (2U) 580 (D) x 438 (W) x 88 (H) (2U)
Net Weight (kgs) 10 15
Environment
Humidity 20-90% RH @ 0-40°C (non-condensing)
Noise Level Less tahn 50dBa @ 1 Meter Less tahn 55dBa @ 1 Meter
Management
Smart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC
*When using internal batteries from 16-19, the unit will de-rate according to the below formula: P = PRating x N/20.
**Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
Product specifications are subject to change without further notice
Product specificaties
Merk: | FSP/Fortron |
Categorie: | UPS |
Model: | Knight KN-1106RL |
Kleur van het product: | Zwart |
Gewicht: | 15000 g |
Breedte: | 438 mm |
Diepte: | 580 mm |
Hoogte: | 88 mm |
Geluidsniveau: | 55 dB |
LED-indicatoren: | Ja |
Vormfactor: | Rackmontage |
Accu/Batterij voltage: | 12 V |
Ondersteund aantal accu's/batterijen: | 20 |
Certificering: | IEC 62040-1\r\nIEC-62040-2\r\nCE |
Geluidsalarm(en): | Ja |
Uitgangsvermogen: | 4800 W |
Batterij capaciteit: | 9 Ah |
Stroomspanning bescherming: | Overbelasting |
Frequentie: | 46/64 Hz |
Power factor: | 0.99 |
Type koeling: | Actief |
Stekker: | C20 stekker |
Efficientie: | 89 procent |
Rackcapaciteit: | 2U |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 20 - 90 procent |
Type beeldscherm: | LCD |
Aantal AC uitgangen: | 4 AC-uitgang(en) |
Stopcontacttypes: | C13 stekker |
Output power capacity: | 6 kVA |
Ingang operation voltage (min): | 110 V |
Ingang operation voltage (max): | 300 V |
Uitgang operation voltage (min): | 200 V |
Uitgang operation voltage (max): | 240 V |
Crest factor: | 3:1 |
Aantal input fases: | 1 |
Typische backup tijd op halve lading: | - min |
Typische backup tijd op volledige lading: | - min |
Output voltage THD: | 3 procent |
Uitgangsspanningsregeling: | 2 procent |
Aantal output fases: | 1 |
Golfvorm: | Sinus |
Output vermogensfactor: | 0.8 |
Heb je hulp nodig?
Als je hulp nodig hebt met FSP/Fortron Knight KN-1106RL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS FSP/Fortron
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
21 Maart 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024