FireAngel ST-630 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor FireAngel ST-630 (16 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
User Manual
Wireless Interlink
Smoke Alarm + 10 Year Life
WST-630
Please retain this user manual for future reference
2
Introduction . . . . . . . . . . . . . 3
Sensor technology . . . . . . . . . . 3
Application . . . . . . . . . . . . . . 3
Positioning . . . . . . . . . . . . . . 4
How to install your
smoke alarm . . . . . . . . . . . . . 5
Interlinking your WST-630
smoke alarms . . . . . . . . . . . . 6
Note: This User Manual is also available in large text and other formats.
Please call for further information0800 141 2561
Operation. . . . . . . . . . . . . . . 8
LED indicators . . . . . . . . . . . . 9
Alarm test . . . . . . . . . . . . . 10
Alarm Smart Silence . . . . . . . . 10
Maintenance . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . 13
Disposal . . . . . . . . . . . . . . 15
Warranty . . . . . . . . . . . . . . 15
CONTENTS
Sprue Safety Products Ltd. Vanguard Centre, Coventry CV4 7EZ UK www.fireangel.co.uk
A Sprue Brand
0832
EN 14604:2005
Smoke Alarm Devices
DoP: SADOPWST-630-01
15
651d/12
Independently tested to:
EN 301489-1 V1.9.2
EN 301489-3 V1.6.1
EN 300220-2 V2.4.1
WST-630
GN1794 / R4
Hereby, Sprue Safety Products Ltd, declares that this
WST-630 is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. The
declaration of conformity may be consulted at
http://spru.es/EC-WST-630
3
thermal enhancement, providing fast response
to both fast aming and smouldering res,
eliminating the need for ionisation sources
which can be harmful to the environment.
The state of the art thermally-enhanced optical
sensing chamber provides a fast reaction to
both slow smouldering and fast aming res
in a single alarm. Thermoptek technology
constantly monitors temperature changes and
if a rate of temperature rise is detected the
sensitivity of the alarm is increased meaning it
has a fast response time to fast aming res as
well as slow smouldering res.
APPLICATION
WARNING: Your smoke alarm can be installed
into a new build property as additional
protection to an existing smoke detection
system only. It cannot be used as a substitute
for a hard wired system as required in new
build properties. In this type of property the
building regulations require alarms to be
interlinked. You can obtain further information
from your local re service or building control
department at your local council ofces. These
sources generally provide advice on new builds
or projects that require planning permission.
Your smoke alarm typically meets the minimum
requirements for family living units in existing
buildings, as long as at least one unit is
installed on each oor/level of your property.
In order to achieve the earliest re warning,
we recommend that a smoke alarm is tted in
all rooms where the temperature is normally
between 4°C (40°F) and 38°C (100°F). Check
the section on ‘Positioning’ to ensure that the
INTRODUCTION
IMPORTANT: This user manual contains
important information regarding the operation
of your smoke alarm. Ensure you read this user
manual fully before installing and operating the
alarm. If you are installing this smoke alarm for
use by others, you must leave this manual (or a
copy of it) with the end user.
Your 10 year life smoke alarm is powered by an
internal lithium power pack which is supplied
in a deactivated state. The power pack is
automatically enabled when the alarm is fully
locked on to the base plate and disabled when
removed.
IMPORTANT: Your alarm will not work until it
is correctly located and secured onto the base
plate.
SENSOR TECHNOLOGY
Traditionally 3 types of sensor technology
have been used in domestic self-contained re
alarms. Optical smoke alarms are typically more
effective at detecting slow burning res, which
can smoulder for hours before bursting into
ames. Ionisation smoke alarms are generally
more effective at detecting fast, aming
res which consume combustible materials
rapidly and spread re quickly. Heat alarms
are triggered when room temperature reaches
a set point (typically 56°C). These alarms are
generally used in locations where other alarm
types are not suitable, such as kitchens.
Ground breaking Thermoptek technology
combines the very latest in optical sensing with


Product specificaties

Merk: FireAngel
Categorie: Rookmelder
Model: ST-630

Heb je hulp nodig?

Als je hulp nodig hebt met FireAngel ST-630 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder FireAngel

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Kidde

Kidde CO120X Handleiding

2 December 2024
EQ-3

EQ-3 HM-Sec-SD-2 Handleiding

30 November 2024
EQ-3

EQ-3 HM-Sec-SD Handleiding

30 November 2024
EQ-3

EQ-3 HMIP-SWSD Handleiding

30 November 2024
Pentatech

Pentatech RA170Q Handleiding

24 November 2024
Cordes

Cordes CC-4100 Handleiding

18 November 2024
Cordes

Cordes CC-3000 Handleiding

18 November 2024
Cordes

Cordes CC-500 Handleiding

18 November 2024
Nexa

Nexa KD-134A Handleiding

18 November 2024
Gloria

Gloria R-5 Handleiding

16 November 2024