Please retain this user manual for future reference
User Manual
10 Year Life Wireless Interlink Smoke Alarm
ST-632 + W2-Module
TEST YOUR ALARM MONTHLY
2
Introduction . . . . . . . . . . . . . . . . 3
Automatic Power Engage . . . . . . . . . 3
Sensor Technology . . . . . . . . . . . . . 3
Positioning . . . . . . . . . . . . . . . . . 3
How to install your Smoke Alarm . . . . . 5
Interlinking your smoke alarms. . . . . . . 6
Operation. . . . . . . . . . . . . . . . . . 8
Note: This User Manual is also available in large text and other formats.
Please call for further information0330 094 5830
LED Indicators . . . . . . . . . . . . . . . 9
Alarm Test . . . . . . . . . . . . . . . . 10
Alarm Smart Silence™ . . . . . . . . . . 10
Sleep Easy™ . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . 13
Maintenance . . . . . . . . . . . . . . . 15
Disposal . . . . . . . . . . . . . . . . . 15
Warranty . . . . . . . . . . . . . . . . . 15
CONTENTS
FireAngel Safety Technology Limited Vanguard Centre, Coventry CV4 7EZ UK www.reangeltech.com
Technical Support: EIRE dial Email: 0330 094 5830 / 1-800 523171 technicalsupport@reangeltech.com
0832-CPR-F2598
EN 14604:2005+AC:2008
Smoke Alarm Devices
FSTDOP19002
Model No. ST-632
19
651d/13
ST-632 + W2-Module
GN5488R1
W2-Module Independently tested to:
EN 301 489-1
EN 301 489-3
EN 300 220-2
Frequency 868MHz
Max RF power: +10dBm
Hereby, FireAngel Safety Technology Limited, declares that
W2-Module is in compliance with the essential require-
ments and other relevant provisions of Directive 2014/53/
EU. The declaration of conformity may be consulted at
http://spru.es/EC-W2-Module
3
THERMOPTEK
TECHNOLOGY
Thermoptek alarms are “toast-proof”
meaning they can be positioned in areas
close to kitchens that may be affected by
cooking fumes. Heat alarms should be used
in kitchens where required.
This combines an optical sensing chamber
with thermal enhancement. The alarm is
effective at detecting slow burning fires, and
constant monitoring of temperature changes
enables the sensitivity of the alarm to be
instantly increased thereby quickening the
typical response time to fast flaming fires
significantly.
POSITIONING
WARNING: Your smoke alarm can be
installed into a new build property as
additional protection to an existing smoke
detection system only. It cannot be used
as a substitute for a hard wired system as
required in new build properties. In this
type of property the building regulations
require alarms to be interlinked. You can
obtain further information from your local
fire service or building control department
at your local council offices. These sources
generally provide advice on new builds or
projects that require planning permission.
Your smoke alarm typically meets the
minimum requirements for family living
units in existing buildings, as long as at least
one unit is installed on each floor/level of
your property.
INTRODUCTION
Groundbreaking Thermoptek technology
combines the very latest in optical sensing
with thermal enhancement, providing faster
response to both re types eliminating the
need for ionisation sources which can be
harmful to the environment. In addition, this
smoke alarm allows the low battery warning
chirp to be silenced until it is convenient to
replace the alarm (recommended within no
more than 30 days).
IMPORTANT: This user manual contains
important information regarding the
operation of your smoke alarm. Ensure you
read this user manual fully before installing
and operating the alarm. If you are installing
this smoke alarm for use by others, you must
leave this manual with the end user.
AUTOMATIC POWER
ENGAGE
Your 10 year life smoke alarm is powered
by an internal lithium battery. To avoid
unnecessary use of the battery prior to
installation, and to ease disposal when
the alarm reaches the end of its life, the
alarm is supplied with the battery in a
deactivated state. The battery on this alarm
is automatically enabled when the alarm is
fully locked on to the base plate.
WARNING: Lithium batteries must not be
exposed to excessive heat.
IMPORTANT: Your alarm will not work until
it is correctly fitted to the base plate.


Product specificaties

Merk: FireAngel
Categorie: Rookmelder
Model: FP2620W2-R

Heb je hulp nodig?

Als je hulp nodig hebt met FireAngel FP2620W2-R stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder FireAngel

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder

Kidde

Kidde 3SFWR Handleiding

24 September 2024
Kidde

Kidde KF30R Handleiding

24 September 2024
Kidde

Kidde P4010ACS-WCA Handleiding

24 September 2024
Kidde

Kidde i12020CA Handleiding

24 September 2024
Kidde

Kidde i12040CA Handleiding

24 September 2024
Kidde

Kidde KF20R Handleiding

24 September 2024
Kidde

Kidde CP9000CA Handleiding

24 September 2024
Kidde

Kidde Pi2010CA Handleiding

24 September 2024