FireAngel HW1-PF-T Handleiding
FireAngel
Rookmelder
HW1-PF-T
Lees hieronder de š handleiding in het Nederlandse voor FireAngel HW1-PF-T (1 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/1
300mm
300mm
1. POSITIONING
Your heat alarm is suitable for the kitchen,
garage and loft.
Heat alarms should be sited at least 300mm
from light fittings and walls. Ideally as central
as possible in the room. Do not install heat
alarms on a wall.
Install your heat alarm at a distance no
greater than 5.3m from the farthest wall, no
greater than 5.3m from a door to any room in
which a fire might start and no greater than
5.3m from the next heat or smoke alarm.
If there is fluorescent lighting, heat alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting.
Do not use circuits containing fluorescent
light fittings or dimmer switches.
If there is fluorescent lighting, heat alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting.
Do not use circuits containing fluorescent
light fittings or dimmer switches.
Locations of alarms must be compliant with
either BS 5839: Part 6 or relevant Building
Regulations if in any doubt.
1a
3. MAINTENANCE
3a Test the alarm every month.
Press the test button for 5
seconds. The alarm will sound.
3b Vacuum your alarm
every 3 months.
5a For multiple alarm installations use a āthree core and earthā style cable between all the alarms to be interconnected.
Connect the interconnect cable between each alarmās 'I' terminal.
5b Test each alarm and ensure every connected alarm
sounds within 10 seconds.
3c Do not use cleaners or solvents. 3d Do not paint the alarm.
TROUBLESHOOTING GUIDE WARRANTY AND DISPOSAL
In a known false alarm, the alarm can be silenced temporarily.
4. SILENCE FEATURE
Up to 12 FireAngel mains smoke (SW1), heat (HW1) or carbon monoxide alarms
(CW1) can be interconnected on a single network.
5. OPTIONAL INTERCONNECTING FEATURE
HW1-PF MAINS POWERED HEAT ALARM
WITH 9V BATTERY BACK-UP
USER MANUAL
Replace the alarm every
10 years.
3e Do not use any other test method except
the process described in this manual.
Your alarm features āSilenceā technology. In the event of a known false alarm you can temporarily silence it by pressing the
button. After 10 minutes your alarm will automatically sound 2 chirps and return to full sensitivity.
The red LED on the front of the alarm will ļ¬ash once every 8 seconds to show that it is in Silence mode.
The alarm will sound continuously and the red LED will ļ¬ash every second when the alarm senses dangerous heat levels. NEVER
IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it. Ignoring the
alarm may result in injury or death. If your heat alarm activates and you are not absolutely certain of the source of the problem,
get everyone out of the house immediately.
4a Press and hold the
button for 5
seconds.
The alarm will silence for
10 minutes.
4b
10
FireAngel Safety Technology Limited warrants to the original purchaser that its enclosed heat alarm be free from defects in materials and
workmanship under normal residential use and service for a period of 5 (ļ¬ve) years from the date of purchase (not including the replaceable
battery). Provided product is sent back to FireAngel Safety Technology Limited with proof and date of purchase, FireAngel Safety Technology
Limited hereby warrants that during the 5 (ļ¬ve) year period commencing from the date of purchase FireAngel Safety Technology Limited, at its
discretion, agrees to replace the unit free of charge. The warranty on any replacement HW1 alarm, will last for the remainder of the period of the
original warranty in respect of the alarm originally purchased ā that is from the date of original purchase and not from the date of receipt of the
replacement product. FireAngel Safety Technology Limited reserves the right to offer an alternative product similar to that being replaced if the
original model is no longer available or in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and
is not transferable. Proof of purchase is required.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or
applications not in accordance with the user manual. It does not cover events and conditions outside of FireAngel Safety Technology Limitedās
control, such as Acts of God (ļ¬re, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. FireAngel
Safety Technology Limited will not recognise any changes to this warranty by third parties.
FireAngel Safety Technology Limited shall not be liable for any incidental or consequential damages caused by the breach of any expressed or
implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or ļ¬tness for a particular purpose is
limited in duration for 5 (ļ¬ve) years.
This warranty does not affect your statutory rights. Except for death or personal injury, FireAngel Safety Technology Limited shall not be liable
for any loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by
you or any other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste. The alarm is ideally suited for disposal within the
waste electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal
advice as regional variations apply.
Once the batteries are removed, the low battery warning chirp will stop. The batteries should always be removed before disposal.
Do not attempt to open. Do not burn.
6. LOW BATTERY WARNING
Your alarm requires 1 x 9V (PP3) battery. Under normal use, the battery should last approximately one year.
Use of a battery other than those recommended here may have a detrimental effect on the alarm performance:
Duracell MN1604, Gold Peak: GP1604S, Raymax: 6F22.
6a When the alarm battery is low, the alarm will āchirpā
and the LED will ļ¬ash once every 32 seconds.
6c Using a screwdriver,
gently open the 3
clips on the base to
remove the alarm.
10
6d Replace the batteries and re-install.
(See 'Installation') 6e Always test the alarm after replacing
the batteries.
On an interconnected network, only the alarm that senses the ļ¬re will sound and ļ¬ash its LED. Other connected alarms will sound a warning but
will not ļ¬ash their LED. Do not connect more than 11 other devices.
IMPORTANT: The interconnect wire (minimum 0.75 mm2 cable) must be treated as Live, it should be insulated and sheathed.
Mains 230V AC
Power Supply
WIRING KEY
= Live
= Interconnect
= Neutral
= Earth
To other alarms
if ļ¬tted
Switch off electricity supply.
6b
ā¢ Check that your heat alarm is connected to the power
supply and that the battery is correctly installed.
ā¢ Check the location of your heat alarm.
ā¢ Clean the heat alarm.
ā¢ Check the location of your heat alarm.
ā¢ Clean the heat alarm.
ā¢ Check that your alarm is connected to the power supply and that the
battery is installed correctly.
ā¢ If testing after installation, allow a few seconds for the alarm to settle.
ā¢ Push and hold the centre of the test button ļ¬rmly for 5 seconds.
ā¢ Check that the alarm is properly connected to the mains power.
ā¢ Check the location of your heat alarm.
ā¢ Check that your heat alarm is deļ¬nitely the source of the chirping; make
sure the noise isnāt coming from another alarm.
ā¢ If the alarm āchirpsā every 32 seconds and the red LED ļ¬ashes at the
same time - replace the battery.
ā¢ If the alarm āchirpsā every 32 seconds without a red LED ļ¬ash, a fault is
indicated - contact Techincal Support.
If the green LED does not light when the alarm
is connected to power:
If your heat alarm does not sound during
testing:
If your heat alarm activates and it is a deļ¬nite
false alarm:
If your heat alarm sounds unusual or āchirpsā
intermittently:
If you experience frequent unwanted alarms:
GN5062R7
Switch off electricity supply.
Ensure a permanent connection to the house wiring is made in a suitable junction box.
Using a screwdriver, gently open the 3 clips on the base
to remove the base plate.
Fit the base to ceiling using the screws provided. Feed the
wiring through the hole in the base plate or via YT2
trunking knock-outs at the side.
Connect the wiring to the connector terminals.
Ensure that the house wiring āEarthā is only
terminated in the terminal
marked ā ā as indicated.
Unwrap battery. Insert battery into battery compartment
(match ā+ā to ā+ā). Press and hold the test / button for
5 seconds. The alarm will sound.
2d
2c
2a
2b
2. INSTALLATION
Turn the electricity supply back on and check
that the green LED is on.
2f
IMPORTANT: The circuit used to Power the alarm must be a 24 hour voltage circuit that cannot be turned off by a switch.
In accordance with BS 5839: Part 6, we recommend: For mains powered alarms, each with an integral standby supply, the mains
electricity supply should take the form of either a) an independent circuit at the dwellingās main circuit board, in which case no
other electrical equipment should be connected to this circuit (other than a dedicated monitoring device installed to indicate
failure of the mains electricity supply to the alarms); or b) a separately electrically protected, regularly used local lighting circuit.
Check with local building and ļ¬re regulations for your property, to ensure compliance.
Ensure dust cover is removed before operation.
The red LED on the front of the alarm should ļ¬ash once every 32 seconds (approx.) to show that the alarm sensor is actively
monitoring for smoke. When the test button is pressed, the alarm will ļ¬ash once every 8 seconds for 8 minutes.
If desired, the alarm can be interconnected with up to 11 other smoke (SW1), heat (HW1) or carbon monoxide (CW1) alarms from
the FireAngel range via the 'I' connector. (See Optional Interconnecting Feature).
IMPORTANT: Align arrows on the side of the alarm and
the side of the base. Gently push alarm onto base.
2e
ALARM TEST:
Press and hold the test / button for
5 seconds. The alarm will sound.
2g
FireAngel Safety Technology Limited. Email: (UK) technicalsupport@ļ¬reangeltech.com, (DE) technik@ļ¬reangeltech.com,
(FR) supporttechnique@ļ¬reangeltech.com, (NL) klantenservice@ļ¬reangeltech.com, (INT) Internationalsupport@ļ¬reangeltech.com
220-240 V AC 50-60 Hz mains powered heat alarm. 9V battery back-up.
WARNING: Wiring should be installed by a qualiļ¬ed electrician in accordance with local building
standards. The wiring must conform to current regulations for electrical installations. Check with local
building and ļ¬re regulations for your property, to ensure compliance.
For the best protection, heat alarms should always be installed as part of a complete ļ¬re protection
system that includes smoke alarms.
Class A2 detection. This heat alarm will sound a warning when the ambient temperature in a room is
between 54Ā°C and 70Ā°C.
This heat alarm is not intended for any non-residential, commercial or industrial application, nor for any
other purpose than described above.
WARNING: Experience has shown that children may not be woken by ļ¬re alarm tones. It is important
that children are never left alone in a house. Families should have a ļ¬re escape plan that is rehearsed, so
that everyone knows how to escape when ļ¬re occurs. The immediate priority when ļ¬re occurs is to
ensure that any sleeping children are woken from sleep and are immediately taken to a place of safety
outside the property, along with all other occupants. The ļ¬re and rescue service should always be called
without delay, no matter how small the ļ¬re. BS 5446-2: 2003
Licence No: KM694292
Ā© FireAngel Safety Technology Limited
Vanguard Centre, Coventry CV4 7EZ, UK
www.ļ¬reangeltech.com
Technical Support
Online: www.ļ¬reangeltech.com/support
E-mail: technicalsupport@ļ¬reangeltech.com
Phone: 0330 094 5830
Fire & Rescue Customers: 0800 141 2561
Note: This user manual is also available in large text and other formats. Please email: technicalsupport@ļ¬reangeltech.com or call 0330 094 5830 for further information.
Product specificaties
Merk: | FireAngel |
Categorie: | Rookmelder |
Model: | HW1-PF-T |
Heb je hulp nodig?
Als je hulp nodig hebt met FireAngel HW1-PF-T stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Rookmelder FireAngel
15 November 2024
15 November 2024
12 Maart 2024
16 November 2023
16 November 2023
16 November 2023
16 November 2023
16 November 2023
15 November 2023
15 November 2023
Handleiding Rookmelder
- Rookmelder Bosch
- Rookmelder IKEA
- Rookmelder Grundig
- Rookmelder Gigaset
- Rookmelder Honeywell
- Rookmelder Siemens
- Rookmelder Abus
- Rookmelder Ajax
- Rookmelder Alecto
- Rookmelder AngelEye
- Rookmelder Bavaria
- Rookmelder Blaupunkt
- Rookmelder Brennenstuhl
- Rookmelder BRK
- Rookmelder BRK DICON
- Rookmelder Denver
- Rookmelder Elgato
- Rookmelder Elro
- Rookmelder Eminent
- Rookmelder EQ-3
- Rookmelder ESYLUX
- Rookmelder Ferguson
- Rookmelder First Alert
- Rookmelder FirstAlert
- Rookmelder Flamingo
- Rookmelder Gira
- Rookmelder Gloria
- Rookmelder Hager
- Rookmelder Hama
- Rookmelder HQ
- Rookmelder Interlogix
- Rookmelder KlikaanKlikuit
- Rookmelder Kogan
- Rookmelder Konig
- Rookmelder Marmitek
- Rookmelder Marquant
- Rookmelder Mercury
- Rookmelder Nedis
- Rookmelder Nest
- Rookmelder Netatmo
- Rookmelder Pyle
- Rookmelder Satel
- Rookmelder Smartwares
- Rookmelder Somfy
- Rookmelder Stabo
- Rookmelder Sygonix
- Rookmelder TFA
- Rookmelder Trust
- Rookmelder Vivanco
- Rookmelder Yale
- Rookmelder Jung
- Rookmelder Olympia
- Rookmelder Clas Ohlson
- Rookmelder Schwaiger
- Rookmelder Steren
- Rookmelder EMOS
- Rookmelder Malmbergs
- Rookmelder DSC
- Rookmelder M-e
- Rookmelder REV
- Rookmelder Chacon
- Rookmelder Nexa
- Rookmelder Swann
- Rookmelder Deltronic
- Rookmelder Ei Electronics
- Rookmelder Fibaro
- Rookmelder FireHawk
- Rookmelder FireX
- Rookmelder Fito
- Rookmelder GEV
- Rookmelder Insafe
- Rookmelder Kidde
- Rookmelder No-Flame
- Rookmelder Pyrexx
- Rookmelder System Sensor
- Rookmelder Dahua Technology
- Rookmelder Busch-Jaeger
- Rookmelder EVE
- Rookmelder Popp
- Rookmelder EQ3
- Rookmelder Homematic IP
- Rookmelder Calex
- Rookmelder Lanberg
- Rookmelder Mobeye
- Rookmelder X-Sense
- Rookmelder Chuango
- Rookmelder ORNO
- Rookmelder ETiger
- Rookmelder TEF
- Rookmelder Jalo Helsinki
- Rookmelder Heatit
- Rookmelder Fito Profi-line
- Rookmelder H-Tronic
- Rookmelder Inovonics
- Rookmelder Pristine
- Rookmelder Cavius
- Rookmelder Jemay
- Rookmelder Pentatech
- Rookmelder Mircom
- Rookmelder WisuAlarm
- Rookmelder Cordes
- Rookmelder SAVS
- Rookmelder STI
- Rookmelder Gewiss
- Rookmelder Egardia
- Rookmelder Frient
- Rookmelder Qolsys
Nieuwste handleidingen voor Rookmelder
18 November 2024
18 November 2024
18 November 2024
18 November 2024
16 November 2024
16 November 2024
15 November 2024
24 September 2024
24 September 2024
24 September 2024