WHALE GP1352 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor WHALE GP1352 (18 pagina's) in de categorie Waterpomp. Deze handleiding was nuttig voor 63 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/18
Thank you for purchasing this Whale® product. For over 60 years, Whale® has led the way in the design and manufacture of freshwater and waste systems including:
pumps, plumbing faucets, showers for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by
excellent customer service. Read carefully before installation and use. For information on our full product range visit: www.whalepumps.com
Designed for use in low voltage applications including leisure boats or recreational vehicles such as caravans or motorhomes to pump cold clean freshwater. If it is
intended for use with any other liquid, it is the user’s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe
working practice is applied to installation, use and maintenance.
CONTENTS
1. Specifi cation
2. Principles of Operation
3. Application
4. Warnings
5. Installation
6. Operation
7. Maintenance
8. Helpful Hints
9. Service Support Details
10. EU Declaration of Conformity, Standards and Approvals
11. Warranty Statement
1
Self-Venting Submersible
& In-Line Booster Pumps
INSTALLATION & USER INSTRUCTIONS
TYPICAL INSTALLATION
LIST OF IMAGES
Fig A. Submersible Pump Installation
Fig B. In-line Pump Installation
1. SPECIFICATION
Model Standard Premium Premium High Flow
Product Code UK Specifi cation GP1002 GP1352 GP1354 GP1652
Product Code EU Specifi cation GP1010 GP1356 GP1358 GP1656
Voltage 12V d.c. 12V d.c. 24V d.c. 24V d.c.
Recommended Fuse Size 5 amp automotive 3 amp automotive 5 amp automotive
Weight 0.15 kg (0.3 lbs)
Hose Connections
Suitable for 10 mm (3⁄8”) or 13 mm ( ”) Flexible Hose½
For ½” hose connection:
Fit adaptor by pressing on fi rmly. Note: Once fi tted adaptors cannot be removed.
For 15mm Quick Connect Plumbing:
Use WX1511B (Stem Adaptor 11 mm-15 mm). Connect WX1504 (15 mm Equal Straight) and then 15 mm Plumbing
For 12mm Quick Connect Plumbing:
Use Whale part: WU1211B, and connect WU1204 and then 12mm plumbing
Material In Contact with Liquid Pump Body: ABS, Seals: Nitrile®, Strainer: Polypropylene, Impeller: PBT, Cable: PVC
Discharge Head
Flow Rate Per Minute
Current Draw
(Note: performance may vary depending on specifi c installations)
0 m (0 ft) 10.3 ltrs 13.2 ltrs 13.2 ltrs 15.75 ltrs
2.4 amps 3.6 amps 3.8 amps 3.8 amps
1 m (3 ft) 8.75 ltrs 11.75 ltrs 11.75 ltrs 14.75 ltrs
2.2 amps 3.3 amps 1.6 amps 3.7 amps
3 m (9 ft) 5.75 ltrs 9.75 ltrs 9.75 ltrs 12.75 ltrs
2.0 amps 2.9 amps 1.455 amps 3.5 amps
Submersible - Model Specifi cations
In Line - Model Specifi cations
Model In-Line Premium In-Line Premium In-Line High Flow
Product Code GP1392 GP1394 GP1692
Voltage 12V d.c. 24V d.c. 12V d.c.
Recommended Fuse Size 5 amp automotive 3 amp automotive 5 amp automotive
Weight 0.15 kg (0.3 lbs)
Hose Connections
Suitable for 10 mm (3⁄8”) or 13 mm ( ”) Flexible Hose½
For ½” hose connection:
Fit adaptor by pressing on fi rmly. Note: Once fi tted adaptors cannot be removed.
For 15mm Quick Connect Plumbing:
Use WX1511B (Stem Adaptor 11 mm-15 mm). Connect WX1504 (15 mm Equal Straight) and then 15 mm Plumbing
For 12mm Quick Connect Plumbing:
Use Whale part: WU1211
Material In Contact with Liquid Pump Body: ABS, Seals: Nitrile®, Strainer: Polypropylene, Impeller: PBT, Cable: PVC
EN
2
Discharge Head Flow Rate Per Minute
Current Draw
0 m (0 ft) 13.2 ltrs 13.2 ltrs 15.75 ltrs
3.6 amps 3.8 amps 3.8 amps
1m (3 ft) 11.75 ltrs 11.75 ltrs 14.75 ltrs
3.3 amps 1.6 amps 3.7 amps
3m (9 ft) 9.75 ltrs 9.75 ltrs 12.75 ltrs
2.9 amps 1.45 amps 3.5 amps
Note: Pump performance will depend on the plumbing system and restrictions on outlets in your installation. Premium and High Flow models come with
3⁄8” (10mm) hose
connection. They can be adapted for ½” (13mm) hose by pushing on the ½” adaptors supplied with the pump. Whale’s policy is one of continuous improvement and we
reserve the right to change specifi cations without prior notice.
To the fi tter
Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read the points listed below. Also
ensure that these operating instructions are passed on to the end user.
To the user
Read the points listed below before installation and use of equipment.
• These pumps are designed to pump clean cold freshwater in low voltage applications such as a leisure boat or recreational vehicle.
• Submersible models designed to be run fully submerged in water, another In-Line Booster pump is designed to be run in the pipe line between the water supply and the
outlet.
• The pumps are rated for intermittent use only- maximum continuous operation should not exceed 15 minutes.
• Ensure that a system of safe working practice is applied to installation, use and maintenance.
• Always disconnect power sources before installing or making connections.
• Wiring must comply with applicable electrical standards and include a 5 Amp automotive fuse for each pump. Improper wiring can cause a fi re resulting in injury or
death. Suggested wiring information is given as a guide only.
• Please note that incorrect installation may invalidate the warranty.
• Not suitable for petrol, low fl ash point liquids and aggressive chemicals. This pump be used for pumping petrol or any highly inmust not fl ammable or corrosive liquids.
• Do not use the pump in water temperatures above 40ºC (100ºF).
• For submersible pump models it is best to stand the pump vertically in the tank.
• Contact Whale® Support on 028 9127 0531 for additional advice on this product or installation.
1. - The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised modiPlease note fi cation or misuse of this product.
2. Before installing, ensure that the system is fully drained before starting the installation. To do this open and close all outlets to expel water and air and check
that the submersible pump can reach the bottom of the water container.
For plumbing connections see Specifi cation table above. The pump outlet be higher than the inlet.MUST
Must be installed in one of the following ways:-
Note: Where there is a long run of pipe between the pump and the faucet, it is helpful to insert a check valve (FV1227) in the pipe close to the faucet.
Step 1
Switch off the 12V d.c. supply
Step 2
Connect to an appropriate 12 or 24 Volt power supply and switch.
Step 3
• Fit the required length of hose to the pump and then fully immerse the pump in the water container.
• To avoid entry of air or water leaks it is important that all hose connections (to pump, tank, water heater and taps / faucets) are securely fastened.
• If using with a Whale In-Line Pressure Switch, (WU7207) an isolator switch installed to protect the pump from accidental switch on when the system is not in must be
use. The pressure switch must be fi tted into the pipework in close proximity to the pump and before any other fi ttings (see Fig. A).
• For plumbing connections see Specifi cation table above
• Must be installed in one of the following ways:-
1. With a foot operated pump (Fig. B1 and Fig. B2). Position the Pump in the suction pipe between the foot pump and the water tank, not between the foot pump and
faucet.
2. In-line to boost a submersible pump (Fig. B3).
3. With a hand operated pump (Fig. B4).
4. In a pressurized system (Fig. B5).
• Where there is a long run of pipe between the pump and the faucet, it is helpful to insert a check valve (FV1227) in the pipe close to the faucet.
Priming the pump.
• When fully immersed in water Submersible pumps are primed and give instant water delivery.
• In-Line Booster pumps primed using either by gravity (as in Fig. B5) or operating a hand pump (Fig. B4) or foot pump (Fig. B1 and Fig. B2) until full water must be fl ow
from the outlet.
o Once primed the pump is ready for use and should remain primed for repeated use.
o As an additional safeguard, a Whale check valve (FV1227) can be inserted in the suction pipe. (Fig. A2 / Fig. B3) re-priming should only be
necessary when the water supply has been completely drained and the tank is refi lled.
o If using a Whale Tiptoe pump, leave the plunger in the “locked down” position whilst operating. Ensure the isolation switch is on. Open the
tap / pump should start.
2. PRINCIPLES OF OPERATION
3. APPLICATION
SUBMERSIBLE PUMP INSTALLATION - See Fig. A
5. INSTALLATION - ALL MODELS
4. WARNINGS
1. With a fl oor pump - Fig. A1
2. With a microswitchwed tap/faucet - Fig. A2 and Fig. A3
3. With a pressure switch system - Fig. A4
• Brown wire to positive
• Blue wire to negative
• Each pump protected with the appropriate fuse
IN-LINE INSTALLATION - See Fig. B
6. OPERATION
3
Whale
Elegance
tap
Whale
faucets
Whale
Babyfoot
pump
Check
valve
Whale
Elegance
tap
Aquasource
clear water
fi lter
Heater
Whale
in-line
pressure
Self-venting submersible pump
Aquasource
clear in-line
water fi lter
Whale
Gusher
Galley
pump
Whale
Babyfoot
pump
Whale
Elegance
tap
Whale hand
pump
Whale
faucet
Water
supplyIn-line
pressure
switch
Check
valve
Heater
In-line booster pump
Check
valve
1 3 4
4 5321
2
Fig. A Fig. B
Notes:
* Do not run the pump dry
* Do not use the pump in water temperature above 40°C (100°F)
• Submersible pump strainers should be inspected and cleaned at frequent intervals to ensure the water supply is free of debris especially from tanks will reduce the
likelihood of pump clog. The pumps are sealed units and do not require further maintenance.
• Winterizing: To protect against damage as a result of freezing, drain the entire water system.
• For Submersibles - Before switching on, place the pump in water and shake for a few seconds to release trapped air. This will ensure successful priming and should be
repeated when the water tank is refi lled.
• For the Whale In-Line Booster pump - Before switching on check that there is water in the tank and that the system has been primed.
• Check that all hose connections are secure and airtight.
• Check that the power supply is at 12 or 24 volts depending on the model. Reduced voltage (i.e. a weak battery) or wire of a thickness of less than AWG #16 may
produce a voltage drop along the cable and reduced performance.
• Ensure that there is adequate ventilation in the water tank to prevent a vacuum building up, causing restricted water fl ow. Any tank or cap fi tting must have a
ventilation hole of at least 3
/16” (5mm) diameter.
• Check that the pump’s polarity is correct i.e. brown to ‘+’ and blue to ‘-’.
• Store in a clean dry place at ambient temperature when not in use.
For installation or serviceable parts advice, please contact Whale Support:- Tel: +44 (0)28 9127 0531 Email info@whalepumps.com
USA Support Tel: +1 616 897 9241 Email usasales@whalepumps.com
Web: www.whalepumps.com
Description of Equipment: Standard, Premium and High Flow pumps
We hereby declare, under our sole responsibility, that the above equipment complies with the provisions of the following EC Directives.
Electromagnetic Compatibility Directive 2004/108/EC.
CE mark affi xed: 20/9/06
Basis on which conformity is declared
The above equipment complies with the protection requirements of the EMC Directive.
Standards applied
EN60335-1:2002 Safety of household and similar electrical appliances.
EN60335-2-41:2003 Particular requirements for pumps.
EN55014-1:2006 & A1:2009 Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus.
Emission.EN55014-1:2006
EN55022:2006 & A1:2007 Information Technology Equipment: Radio disturbance characteristics - limits and methods of measurement.
Signed (Authorised person)
Richard Bovill
Engineering Director
©Copyright Whale 2017 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE®, is a registered trademark of Munster Simms
Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale’s policy is one of continuous improvement and we reserve the right to change specifi cations
without prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information contained in any Product brochure is
guaranteed by the Company and may be subject to change at its sole discretion. Please note that by contacting Whale Support you will be indicating your consent to
receiving product updates, recall information, help guides and appropriate marketing messages from us via post, email or telephone unless you indicated an objection to
receiving such messages.
Munster Simms Engineering Ltd (Whale)
2 Enterprise Road, Bangor, Co Down, N. Ireland BT19 7TA
Tel: +44 (0)28 9127 0531 Web: www.whalepumps.com Email: info@whalepumps.com
7. MAINTENANCE
8. HELPFUL HINTS
9. SERVICE SUPPORT DETAILS
10. EU DECLARATION OF CONFORMITY
11. WARRANTY
Ref: 181.01_v8_0417_db
Product specificaties
Merk: | WHALE |
Categorie: | Waterpomp |
Model: | GP1352 |
Heb je hulp nodig?
Als je hulp nodig hebt met WHALE GP1352 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterpomp WHALE
19 Juli 2024
19 Juli 2024
19 Juli 2024
19 Juli 2024
14 Juni 2023
27 Mei 2023
29 April 2023
16 April 2023
1 Maart 2023
5 December 2022
Handleiding Waterpomp
- Waterpomp LG
- Waterpomp Karcher
- Waterpomp Al-ko
- Waterpomp Atlantic
- Waterpomp Bavaria
- Waterpomp Bestway
- Waterpomp Buderus
- Waterpomp Bulex
- Waterpomp Daikin
- Waterpomp Danfoss
- Waterpomp De Dietrich
- Waterpomp Dimplex
- Waterpomp Dometic
- Waterpomp Duro Pro
- Waterpomp Duromax
- Waterpomp Eden
- Waterpomp Eheim
- Waterpomp Einhell
- Waterpomp Eurogarden
- Waterpomp Eurom
- Waterpomp Ferrex
- Waterpomp Florabest
- Waterpomp Fujitsu
- Waterpomp Garden Feelings
- Waterpomp Gardena
- Waterpomp Gardenline
- Waterpomp Germania
- Waterpomp GRE
- Waterpomp Gree
- Waterpomp Gude
- Waterpomp Hayward
- Waterpomp Hitachi
- Waterpomp Hozelock
- Waterpomp Hydro-Pro
- Waterpomp Hyundai
- Waterpomp Intex
- Waterpomp Kibani
- Waterpomp Kranzle
- Waterpomp Makita
- Waterpomp Maxicool
- Waterpomp Maxxmee
- Waterpomp Metabo
- Waterpomp Mitsubishi
- Waterpomp Nibe
- Waterpomp Parkside
- Waterpomp Pattfield
- Waterpomp Plantiflor
- Waterpomp REMKO
- Waterpomp Ryobi
- Waterpomp Scheppach
- Waterpomp Silverline
- Waterpomp Tanaka
- Waterpomp Toolcraft
- Waterpomp Topcraft
- Waterpomp Trotec
- Waterpomp Vetus
- Waterpomp Viessmann
- Waterpomp Vonroc
- Waterpomp Westfalia
- Waterpomp WilTec
- Waterpomp Wingart
- Waterpomp Zipper
- Waterpomp Jung
- Waterpomp Oase
- Waterpomp OKAY
- Waterpomp Cocraft
- Waterpomp Meec Tools
- Waterpomp Fluval
- Waterpomp Tetra
- Waterpomp Cotech
- Waterpomp Truper
- Waterpomp Fieldmann
- Waterpomp SereneLife
- Waterpomp Little Giant
- Waterpomp CMI
- Waterpomp Hecht
- Waterpomp Sthor
- Waterpomp Alphacool
- Waterpomp FIAP
- Waterpomp Neptun
- Waterpomp Pontec
- Waterpomp Sunforce
- Waterpomp VT
- Waterpomp Yato
- Waterpomp Jabsco
- Waterpomp Swim & Fun
- Waterpomp Norsup
- Waterpomp Flotide
- Waterpomp For_Q
- Waterpomp Coral Box
- Waterpomp Wolfcraft
- Waterpomp DAB
- Waterpomp Anova
- Waterpomp Esotec
- Waterpomp T.I.P.
- Waterpomp Elpumps
- Waterpomp Liberty Pumps
- Waterpomp Waterco
- Waterpomp Ashland
- Waterpomp Nowax
- Waterpomp Zoeller
- Waterpomp Pentair
- Waterpomp Proviel
- Waterpomp Sunnydaze Decor
- Waterpomp GARANTIA
- Waterpomp Ribimex
- Waterpomp Reefe
- Waterpomp Ebara
- Waterpomp Ergotools Pattfield
- Waterpomp AquaForte
- Waterpomp Heissner
- Waterpomp Maxbear
- Waterpomp Yellow Garden Line
- Waterpomp Tallas
Nieuwste handleidingen voor Waterpomp
15 November 2024
14 November 2024
13 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024