WHALE Supersub Smart 650 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor WHALE Supersub Smart 650 (40 pagina's) in de categorie Waterpomp. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/40
Model Number SS5012 (B) Supersub 500 (12V d.c)
Model Number SS5022 (B) Supersub 650 (12V d.c) with N.R.V
Model Number SS1012 (B) Supersub 1100 (12V d.c) with N.R.V
Model Number SS1024 (B) Supersub 1100 (24V d.c) with N.R.V
Installation Guidelines for:
This booklet must be read prior to installation
Model Number SS5212 (B) Supersub Smart 650 (12V d.c) with N.R.V
Model Number SS1212 (B) Supersub Smart 1100 (12V d.c) with N.R.V
Model Number SS1224 (B) Supersub Smart 1100 (24V d.c) with N.R.V
Standard Pumps (separate bilge switch required)
Automatic Pumps
Supersub
Range
Model shown: SS5212
Mounting wedge is supplied with automatic pumps only.
* B Suffix refers to bulk packed versions
N.R.V = Non Return Valve
The original low profile narrow electric bilge pump.
Please Note: Pump operates with a 5 second on delay on automatic setting
Supersub
Range
EN
Munster Simms Engineering Ltd, 2 Enterprise Road, Bangor, Co Down, N. Ireland BT19 7TA
Tel: +44 (0)28 9127 0531 Web: www.whalepumps.com Email info@whalepumps.com
Thank you for purchasing this Whale product.
For over 60 years Whale has led the way in the design and manufacture of freshwater, bilge and waste management systems including plumbing,
taps, showers and pumps, for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation
backed up by excellent customer service. For information on our full product range visit: www.whalepumps.com
CONTENTS LIST OF IMAGES
To the fitter
Read the following carefully before installation. Check that the product is suitable for the intended application, follow these installation instructions
and ensure all relevant personnel read the points below. Also ensure that these operating instructions are passed on to the end user.
WARNING: Please note that incorrect installation may invalidate warranty.
To the user
Read the following instructions carefully.
OF OPERATION
All Supersub models are uniquely designed, specifically for fast and efficient removal of bilge water from leisure craft. The Supersub range fits into
narrow and low spaces that other bilge pumps cannot reach. SS5012, SS5022, SS1012 AND SS1024 ARE NOT AUTOMATIC PUMPS. (Please
refer to Section 4 for the switches and optional extras that can be used with these products).
Supersub Smart 650 and 1100 are automatic. The pump will sense the presence of water and will switch on, then will turn off again when the
water level has dropped. The switching is solid state hence there are no moving parts. The Supersub Smart models allow waves of water to pass
over, without turning the pump on every time, as it has a built in time delay.
• The Supersub and Supersub Smart range of products are designed to pump normal bilge water. Output capacity depends on installation and
operating conditions. If this product is intended to be used for any other purpose or with any other liquid, it is the user's responsibility to ensure
that the pump is suitable for the application and, in particular, that the materials are fully compatible with the liquids to be used.
• This product must only be used in the bilges of leisure craft. If this product is to be used as the sole and/or primary bilge pump, the
Supersub 500/650/1100 and Supersub Smart 650/1100 pumps must only be used in boats up to 24m (78.8 ft).
• The bilge water must only be evacuated through a correctly installed skin fitting above the water line of the boat.
• With all applications, it is important that a system of safe working practice is applied to installation, use and maintenance. Ensure the electric
supply is turned off and waste water system is drained before installation.
• The Supersub range is designed only for the removal of normal bilge water in leisure boats and personal watercraft (as explained in
Section 2 - Application). Your warranty may be invalidated if the product is used in other applications or outside the remit of the standards
quoted on the packaging and pump body.
•NOTE: Bilge pump capacities may not be sufficient to prevent flooding from rapid accumulation of water due to storms, rough weather and/ or
rapid leaks created by hull damage and or unsafe navigational conditions.
• The pumped water must be evacuated through a skin fitting above the water line (see typical installation diagrams). The Supersub and
Supersub Smart range is not for use in systems evacuating water through a skin fitting or seacock below the water line. All pipework must
contain a correctly installed anti-syphon valve / loop.
• In order to securely fasten the unit, ensure that the mounting surface is a minimum thickness of 19mm (3/4") (screws supplied with retail models
only). NOTE Do not must be screw directly to the hull - mounted on a bulkhead or on an additional board.
•NOTE - DO NOT unscrew the rear section, as interference with the internal electrics will render the pump unfit for use. - this is a
non-serviceable part of the pump.
•WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a properly rated fuse or circuit breaker. Improper
wiring can cause a fire resulting in injury or death. Switch off the power while making connections.
LV1219 Non-Return Valve (recommended for SS5012 models) .
BE9003 / BE9006 Automatic, water activated, electronic switch (For use with SS5012, SS5022, SS1012 and SS1024 models).
BE9002 Automatic, water activated, floatswitch (Please see Figure 5, Supersub Automatic System).
SF5131 3/4” Skin fitting (for use with SS5012, SS5022 and SS5212 models)
SF5204 1” Skin Fitting (for use with SS1012, SS1024, SS1212 and SS1224 models)
See diagrams (page 4)
1. Principles of Operation 6. Instructions for use
2. Application 7. Trouble shooting
3. Warning 8. Winterization
4. Optional Extras 9. Service Support & Warranty
5. Installation Instructions 10. Declaration of conformity, standards, approvals
Figure 1. Installation & Recommendations
Figure 2. Fitting Instructions
Figure 3. Fitting Instructions - Into Existing Drill Holes
Figure 4. Typical Installations
Figure 5. Wiring Diagrams
Figure 6. Plumbing
Figure 7. Maintenance
1. Principles of Operation
2. Application
3. Warning
4. Optional Extras
2
5. Installation Instructions
Supersub
Range 3
Munster Simms Engineering Ltd, 2 Enterprise Road, Bangor, Co Down, N. Ireland BT19 7TA
Tel: +44 (0)28 9127 0531 Web: www.whalepumps.com Email info@whalepumps.com
SS5012, SS5022, SS1012 and SS1024 - Manual System:
Step 1: When fitted on their own, these pumps must be activated by putting the switch into the ON position (Figure 5, Supersub Manual System).
Step 2: The Supersub must be turned off as soon as the water has been evacuated from the bilge, as running the pump when it is dry will shorten
the life of the pump.
SS5012, SS5022, SS1012 and SS1024 - Automatic System:
Step 1: When used with BE9002, BE9003 or BE9006 the pump can be left on automatic or switched to manual activation (Figure 5, Supersub
Automatic System).
SS5212, SS1212 and SS1224:
Step 1: Set the 3 way switch to Automatic (Figure 5 Supersub Smart 650/1100), the pump will run when necessary. Place fingers over sensor area
to check pump is activated (wait 5 seconds), remove fingers and wait for the pump to stop (25 seconds). Check pump regularly to ensure no
clogging occurs (Figure 7).
Freezing in winter may cause damage to the Supersub range of products. To avoid this damage, ensure water is removed from the bilge on a
regular basis, especially before and during winter months.
The Supersub range is a non-serviceable product range. If the pump fails due to mishandling or if the product is outside of its warranty period, a new
pump must be purchased. For full warranty statement please see document enclosed. Due to extreme conditions found in the bilge of boats, we
recommend that your submersible bilge pump is replaced at least every 3 years, this is due to temperature changes and the different chemical
environments. For installation or serviceable parts advice please contact Whale® Customer Support:
UK: Tel: +44 (0)28 9127 0531 Email: info@whalepumps.com www.whalepumps.com
USA: Tel: +1 (616) 897-2301 Email: usasales@whalepumps.com www.whalepumps.com
6. Instructions for Use
PROBLEM POSSIBLE CAUSES POSSIBLE SOLUTIONS
Limited flow
Blocked or dirty filter and / or impeller Check for blockages in filter/impeller. Clean with warm soapy water
(Do not use any chemical cleaning agents)
Blocked or dirty pipe work and/or
connections
Disconnect pump and check flow through pipe work, unblock or
clean as necessary
Narrow pipe work or connections Replace narrow aperture connections and any crushed or
collapsed pipe work
Low battery power Check battery level, refill or recharge as necessary
No flow
Completely blocked filter and / or impeller Check for blockages in filter/impeller. Clean with warm soapy water
(Do not use any chemical cleaning agents)
Blocked or dirty pipe work and/or
connections
Disconnect pump and check flow through pipe work, unblock or
clean as necessary
Blown fuse Check above two remedies first. Replace with appropriate fuse
Flat battery Check battery level, replace, refill or recharge as necessary
Incorrectly located sensor Consult Installation Instructions, available with product or on website
Pump failure Check within 1 year warranty. Contact retailer and replace pump
Runs continuously
Switching error
Faulty on/off switch
Incorrectly located automatic switch
Faulty float switch/ electric field switch
Float switch stuck upright (Manual version)
Check there are no moving bodies within the bilge that may prevent
movement of the float
Ensure free movement of float switch
Electric field sensor remains activated
Wrong pump orientation, consult Installation Instructions, available with
product or on website
Check there are no moving bodies within the bilge that may cover the
area where the sensor is located
Sensor too close to pipe work, boat structure or other body of mass
If there is thick debris on sensor - wipe clean
8. Winterization
9. Service Support & Warranty
7. Trouble Shooting
EN
Product specificaties
Merk: | WHALE |
Categorie: | Waterpomp |
Model: | Supersub Smart 650 |
Heb je hulp nodig?
Als je hulp nodig hebt met WHALE Supersub Smart 650 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterpomp WHALE
19 Juli 2024
19 Juli 2024
19 Juli 2024
19 Juli 2024
14 Juni 2023
27 Mei 2023
29 April 2023
16 April 2023
1 Maart 2023
5 December 2022
Handleiding Waterpomp
- Waterpomp LG
- Waterpomp Karcher
- Waterpomp Al-ko
- Waterpomp Atlantic
- Waterpomp Bavaria
- Waterpomp Bestway
- Waterpomp Buderus
- Waterpomp Bulex
- Waterpomp Daikin
- Waterpomp Danfoss
- Waterpomp De Dietrich
- Waterpomp Dimplex
- Waterpomp Dometic
- Waterpomp Duro Pro
- Waterpomp Duromax
- Waterpomp Eden
- Waterpomp Eheim
- Waterpomp Einhell
- Waterpomp Eurogarden
- Waterpomp Eurom
- Waterpomp Ferrex
- Waterpomp Florabest
- Waterpomp Fujitsu
- Waterpomp Garden Feelings
- Waterpomp Gardena
- Waterpomp Gardenline
- Waterpomp Germania
- Waterpomp GRE
- Waterpomp Gree
- Waterpomp Gude
- Waterpomp Hayward
- Waterpomp Hitachi
- Waterpomp Hozelock
- Waterpomp Hydro-Pro
- Waterpomp Hyundai
- Waterpomp Intex
- Waterpomp Kibani
- Waterpomp Kranzle
- Waterpomp Makita
- Waterpomp Maxicool
- Waterpomp Maxxmee
- Waterpomp Metabo
- Waterpomp Mitsubishi
- Waterpomp Nibe
- Waterpomp Parkside
- Waterpomp Pattfield
- Waterpomp Plantiflor
- Waterpomp REMKO
- Waterpomp Ryobi
- Waterpomp Scheppach
- Waterpomp Silverline
- Waterpomp Tanaka
- Waterpomp Toolcraft
- Waterpomp Topcraft
- Waterpomp Trotec
- Waterpomp Vetus
- Waterpomp Viessmann
- Waterpomp Vonroc
- Waterpomp Westfalia
- Waterpomp WilTec
- Waterpomp Wingart
- Waterpomp Zipper
- Waterpomp Jung
- Waterpomp Oase
- Waterpomp OKAY
- Waterpomp Cocraft
- Waterpomp Meec Tools
- Waterpomp Fluval
- Waterpomp Tetra
- Waterpomp Cotech
- Waterpomp Truper
- Waterpomp Fieldmann
- Waterpomp SereneLife
- Waterpomp Little Giant
- Waterpomp CMI
- Waterpomp Hecht
- Waterpomp Sthor
- Waterpomp Alphacool
- Waterpomp FIAP
- Waterpomp Neptun
- Waterpomp Pontec
- Waterpomp Sunforce
- Waterpomp VT
- Waterpomp Yato
- Waterpomp Jabsco
- Waterpomp Swim & Fun
- Waterpomp Norsup
- Waterpomp Flotide
- Waterpomp For_Q
- Waterpomp Coral Box
- Waterpomp Wolfcraft
- Waterpomp DAB
- Waterpomp Anova
- Waterpomp Esotec
- Waterpomp T.I.P.
- Waterpomp Elpumps
- Waterpomp Liberty Pumps
- Waterpomp Waterco
- Waterpomp Ashland
- Waterpomp Nowax
- Waterpomp Zoeller
- Waterpomp Pentair
- Waterpomp Proviel
- Waterpomp Sunnydaze Decor
- Waterpomp GARANTIA
- Waterpomp Ribimex
- Waterpomp Reefe
- Waterpomp Ebara
- Waterpomp Ergotools Pattfield
- Waterpomp AquaForte
- Waterpomp Heissner
- Waterpomp Maxbear
- Waterpomp Yellow Garden Line
- Waterpomp Tallas
Nieuwste handleidingen voor Waterpomp
15 November 2024
14 November 2024
13 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024