WHALE Orca 500 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor WHALE Orca 500 (28 pagina's) in de categorie Waterpomp. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/28
INSTALLATION AND OPERATION MANUAL
Orca Submersible Pump Range
* (B) suffix represents a bulk item code
Model Number Description
BE0500 Orca 500 - 12 V d.c.
BE0950 Orca 950 - 12 V d.c.
BE1450 Orca 1300 - 12 V d.c.
BE1454 Orca 1300 - 24 V d.c.
BE2002(B) Orca 2000 - 12 V d.c.
BE2004(B) Orca 2000 - 24 V d.c.
BE3002(B) Orca 3000 - 12 V d.c.
BE3004(B) Orca 3000 - 24 V d.c.
2
INSTALLATION AND OPERATION MANUAL
Thank you for purchasing this Whale® product. For over 60 years Whale® has led the way in the
design and manufacturer of freshwater and waste systems including:- plumbing, faucets, showers
and pumps for low voltage applications. The company and its products have built a reputation for
quality, reliability and innovation backed up by excellent customer service.
For information on our full product range visit: www.whalepumps.com
* Flow rates are stated in accordance with ABYC recommendations at a voltage of 13.6 V d.c.
The Orca submersible electric bilge pump range is designed for use as a bilge pump on marine
vessels. These high capacity pumps are compact and powerful, designed for bilge water evacuation.
Read the following instructions carefully before installing and using the equipment.
Check that the product is suitable for the intended application, follow these installation instructions
and ensure all relevant personnel read the points listed below. Also ensure that these operating
instructions are passed on to the end user.
This Whale Orca Electric Bilge Pump is designed for use as a bilge pump in marine vessels to pump
bilge water only.
1. This pump outlet must be mounted at least 305mm (12”) above the water
line when connected to an intake located below the water line.
2. Not suitable for pumping flammable liquids, diesel, chemicals etc. For use
in a bilge system only.
3. This pump is designed to exhaust standing water only. These pumps are not intended
for damage control. Bilge pump capacities may not be sufficient to prevent flooding
from rapid accumulation of water due to storms, rough weather and/ or rapid leaks
created by hull damaged and or unsafe navigational conditions.
4. With all applications, it is important that a system of safe working practice is applied to
installation, use and maintenance. Ensure the electric supply is turned off.
5. In order to securely fasten this unit, ensure that the mounting surface is a minimum
1. SPECIFICATION
2. PRINCIPALS OF OPERATION
3. TO THE USER
4. TO THE FITTER
Model 500 US GPH
(32 ltrs/min)
950 US GPH
(57 ltrs/min)
1300 US GPH
(82 ltrs/min)
2000 GPH
(126 ltrs/min)
3000 GPH
(189 ltrs/min)
Product Code BE0500 BE0950 BE1450 BE1454 BE2002(B) BE2004(B) BE3002(B) BE3004(B)
Open Flow Rate @
13.6 V d.c
500 GPH
(32 ltrs/min)
950GPH
(57 ltrs/min)
1300GPH
(82 ltrs/min)
2000 GPH
(126 ltrs/min)
3000 GPH
(189 ltrs/min)
Flow Rate @
1m (3ft) Head
450 GPH
(26ltrs/min)
850 GPH
(52 ltrs/min)
1100 GPH
(65 ltrs/min)
1650 GPH
(104 ltrs/min)
2700 GPH
(170 ltrs/min)
Nominal Voltage 12 V d.c. 24 V d.c. 12 V d.c. 24 V d.c. 12 V d.c. 24 V d.c.
Current Draw 1.5 amps 3.5 amps 5.0 amps 2.5 amps 10.0 amps 5.0 amps 18.0 amps 9.0 amps
Recommended Fuse 2.0 amps 5.0 amps 7.0 amps 5.0 amps 15.0 amps 8.0 amps 27.0 amps 13.0 amps
Weight 0.28 kg
(0.62lbs)
0.45 kg
(0.99lbs)
0.82 kg
(1.81lbs)
1.32 kg
(2.91lbs)
2.64 kg
(5.82lbs)
Hose Connections 3/4” (19 mm) 1” (25mm) and 1 1/8” (28mm) 1 1/8” (28mm) 1 1/4” (32mm)
Wire Size 1.3mm² (16 AWG) 2mm² (14 AWG)
Materials Pump body: ABS, Seals: Nitrile, :Impeller
Acetal
Pump body Seals: Polypropylene, : Nitrile,
Impeller: Acetal
Maximum Discharge
Head
3.0 m
(9.8 ft)
3.5 m
(11.5 ft)
4.5 m
(14.8 ft)
4m
(13ft)
4.6m
(15ft)
5. APPLICATION
6. WARNINGS
ENG
3
thickness of 19mm (3/4”). Do screw directly onto the hull, it must be mounted to NOT
a bulkhead or on an additional board.
1 x Orca Pump 1 x Screw Kit
BE9003 / BE9006 - Electric Field Sensor Switch (Available separately)
WARNING: Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
9.1 Location
• Position pump in the lowest accessible
part of the bilge. On sailboats, location
should be centred over keel (Fig 1).
• mount the pump directly onto Do not
the hull. The base strainer must be
mounted to a bulkhead or an additional
board at least 19mm (3/4”) thick.
9.2 Mounting Instructions
Before drilling, ensure that the mounted pump will be correctly positioned with the pump nozzle
pointing towards thru-hull connector.
To remove pump body, place hand over body, depress locking tabs and lift body from strainer base.
Note: Motor will be removed with body (see figure 2 and 3).
For Orca 500, 950, 1300 and 2000
• Use base as template to mark 3 mounting holes for Orca in
mounting pad.
• Remove base. Drill three 1/8" (3mm) pilot holes for Orca at
marked locations.
• Replace base. Attach with #8 stainless steel fasteners
(supplied).
• Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figures 2
and 3).
For Orca 3000
• Use base as template to mark 4 mounting holes for Orca
3000 in mounting pad.
• Remove base. Drill four 1/8" (3mm) pilot holes for Orca
3000 at marked locations.
• Replace base. Attach with #8 stainless steel fasteners
(supplied).
• Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figure 3).
9.3 Plumbing
IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector with
no dips or sharp bends. Hose support clips should be used at regular intervals where necessary.
• Orientate the pump outlet for a direct path to the hull connector ensuring an
unobstructed hose path.
• Secure all connections with hose clamps.
• If no thru-hull connector exists, install at 12" (305mm) minimum height above water
line. Apply marine sealant around thru-hull flanges on interior and exterior of hull.
7. PARTS LIST
9. INSTALLATION
Press both
locking tabs
to release
cover
Figure 2 - Release Cover
Orca 500, 950 and 1300
Press
both
locking
tabs to
release
cover
Figure 3 - Release
Cover Orca 2000
and 3000
8. OPTIONAL EXTRAS
Figure 1 -
Mounting Location
Skin Fittings
Suitable Mounting Pad
Hose must rise upwards
with NO DIPS
Outlet 12”
(305mm)
minimum
above
water line
Product specificaties
Merk: | WHALE |
Categorie: | Waterpomp |
Model: | Orca 500 |
Heb je hulp nodig?
Als je hulp nodig hebt met WHALE Orca 500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterpomp WHALE
19 Juli 2024
19 Juli 2024
19 Juli 2024
19 Juli 2024
14 Juni 2023
27 Mei 2023
29 April 2023
16 April 2023
1 Maart 2023
5 December 2022
Handleiding Waterpomp
- Waterpomp LG
- Waterpomp Karcher
- Waterpomp Al-ko
- Waterpomp Atlantic
- Waterpomp Bavaria
- Waterpomp Bestway
- Waterpomp Buderus
- Waterpomp Bulex
- Waterpomp Daikin
- Waterpomp Danfoss
- Waterpomp De Dietrich
- Waterpomp Dimplex
- Waterpomp Dometic
- Waterpomp Duro Pro
- Waterpomp Duromax
- Waterpomp Eden
- Waterpomp Eheim
- Waterpomp Einhell
- Waterpomp Eurogarden
- Waterpomp Eurom
- Waterpomp Ferrex
- Waterpomp Florabest
- Waterpomp Fujitsu
- Waterpomp Garden Feelings
- Waterpomp Gardena
- Waterpomp Gardenline
- Waterpomp Germania
- Waterpomp GRE
- Waterpomp Gree
- Waterpomp Gude
- Waterpomp Hayward
- Waterpomp Hitachi
- Waterpomp Hozelock
- Waterpomp Hydro-Pro
- Waterpomp Hyundai
- Waterpomp Intex
- Waterpomp Kibani
- Waterpomp Kranzle
- Waterpomp Makita
- Waterpomp Maxicool
- Waterpomp Maxxmee
- Waterpomp Metabo
- Waterpomp Mitsubishi
- Waterpomp Nibe
- Waterpomp Parkside
- Waterpomp Pattfield
- Waterpomp Plantiflor
- Waterpomp REMKO
- Waterpomp Ryobi
- Waterpomp Scheppach
- Waterpomp Silverline
- Waterpomp Tanaka
- Waterpomp Toolcraft
- Waterpomp Topcraft
- Waterpomp Trotec
- Waterpomp Vetus
- Waterpomp Viessmann
- Waterpomp Vonroc
- Waterpomp Westfalia
- Waterpomp WilTec
- Waterpomp Wingart
- Waterpomp Zipper
- Waterpomp Jung
- Waterpomp Oase
- Waterpomp OKAY
- Waterpomp Cocraft
- Waterpomp Meec Tools
- Waterpomp Fluval
- Waterpomp Tetra
- Waterpomp Cotech
- Waterpomp Truper
- Waterpomp Fieldmann
- Waterpomp SereneLife
- Waterpomp Little Giant
- Waterpomp CMI
- Waterpomp Hecht
- Waterpomp Sthor
- Waterpomp Alphacool
- Waterpomp FIAP
- Waterpomp Neptun
- Waterpomp Pontec
- Waterpomp Sunforce
- Waterpomp VT
- Waterpomp Yato
- Waterpomp Jabsco
- Waterpomp Swim & Fun
- Waterpomp Norsup
- Waterpomp Flotide
- Waterpomp For_Q
- Waterpomp Coral Box
- Waterpomp Wolfcraft
- Waterpomp DAB
- Waterpomp Anova
- Waterpomp Esotec
- Waterpomp T.I.P.
- Waterpomp Elpumps
- Waterpomp Liberty Pumps
- Waterpomp Waterco
- Waterpomp Ashland
- Waterpomp Nowax
- Waterpomp Zoeller
- Waterpomp Pentair
- Waterpomp Proviel
- Waterpomp Sunnydaze Decor
- Waterpomp GARANTIA
- Waterpomp Ribimex
- Waterpomp Reefe
- Waterpomp Ebara
- Waterpomp Ergotools Pattfield
- Waterpomp AquaForte
- Waterpomp Heissner
- Waterpomp Maxbear
- Waterpomp Yellow Garden Line
- Waterpomp Tallas
Nieuwste handleidingen voor Waterpomp
15 November 2024
14 November 2024
13 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024
11 November 2024