Tripp Lite SmartPro SMC15002URM Handleiding
Tripp Lite
UPS
SmartPro SMC15002URM
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SmartPro SMC15002URM (56 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/56
1
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Important Safety Instructions 2
Mounting 4
Quick Installation 6
Optional Installation 7
Basic Operation 8
Storage and Service 16
Battery Replacement 17
Product Registration 19
Regulatory Compliance 19
Español 20
Français 39
SmartPro® SMC 2U Rackmount
Intelligent, Line-Interactive UPS Systems
120V Sine Wave Output • 1,000VA—1,500VA
SMC10002URM
(Series No. AGSM8267)
SMC15002URM
(Series No. AG-0007)
Not suitable for mobile applications.
Copyright © 2014 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
PROTECT YOUR INVESTMENT!
Register your product for quicker service and ultimate peace of mind.
You could also win an ISOBAR6ULTRA surge protector—a $50 value!
www.tripplite.com/warranty
14-08-107-93-33B2.indb 1 9/25/2014 12:29:28 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during the installation, operation
and storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• Use caution when lifting the UPS. Because of the considerable weight of all rackmount UPS
systems, at least two people should assist in lifting and installing them.
• Install the UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, the ambient temperature near the UPS should be between 0° C and 40° C
(between 32° F and 104° F).
• Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents
or fan openings.
• When mounting the UPS system in a tower orientation, make sure the LCD Screen panel is at the
top of the UPS, not at the bottom.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner
may eventually cause product damage not covered under warranty.
UPS Connection Warnings
• The UPS contains its own energy source (battery). The output terminals may be live even when the
UPS is not connected to an AC supply.
• Connect the UPS to a properly grounded AC power outlet. Do not modify the UPS’s plug in a way
that would eliminate the UPS’s connection to ground. Do not use adapters that eliminate the UPS’s
connection to ground.
• Do not plug the UPS into itself; this will damage the UPS and void your warranty.
• If you are connecting the UPS to a motor-powered AC generator, the generator must provide
filtered, frequency-regulated computer-grade output. Connecting the UPS to a generator will void
its Ultimate Lifetime Insurance.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably
be expected to cause the failure of the life support equipment or to significantly affect its safety
or effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of the UPS. This might damage
the UPS and may affect the surge suppressor and UPS warranties.
14-08-107-93-33B2.indb 2 9/25/2014 12:29:28 PM
3
Battery Warnings
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe
proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries.
Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before
performing battery replacement. Use tools with insulated handles. There are no user-serviceable
parts inside the UPS. Battery replacement should be performed only by authorized service personnel
using the same number and type of batteries (Sealed Lead-Acid). Tripp Lite offers a complete line
of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.
com/support/battery/index.cfm to locate the specific replacement battery for your UPS. The RBC
Type can also be found on the label affixed to the Battery Retention Plate.
• During hot-swap battery replacement, the UPS will not provide backup power in the event of a
blackout or other power interruptions.
• Do not operate the UPS without batteries.
UPS and Battery Recycling
Please recycle Tripp Lite Products. The batteries used in Tripp Lite products are sealed
Lead-Acid batteries. These batteries are highly recyclable. Please refer to your local codes
for disposal requirements.
You can call Tripp Lite for recycling info at 1-773-869-1234.
You can go the Tripp Lite Website for up-to-date information on recycling the batteries or any Tripp Lite
product. Please follow this link: http://www.tripplite.com/support/recycling-program/
Important Safety Instructions
14-08-107-93-33B2.indb 3 9/25/2014 12:29:28 PM
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | SmartPro SMC15002URM |
Kleur van het product: | Zwart |
Gewicht: | 21090 g |
Breedte: | 439.4 mm |
Diepte: | 341.6 mm |
Hoogte: | 87.6 mm |
Snoerlengte: | 3 m |
Geluidsniveau: | 45 dB |
Gewicht verpakking: | 23950 g |
Breedte verpakking: | 508 mm |
Diepte verpakking: | 594.4 mm |
Hoogte verpakking: | 221 mm |
Materiaal behuizing: | Staal |
LED-indicatoren: | Ja |
Vormfactor: | Rackmontage/toren |
Ingebouwde ventilator: | Ja |
Land van herkomst: | Taiwan |
Aantal USB 2.0-poorten: | 1 |
Certificering: | FCC Part 15 Category A (EMI)\r\nCSA\r\nNOM\r\nUL1778 |
RS-232 port: | 1 |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 1000 W |
Accu/Batterij oplaadtijd: | 4.5 uur |
Temperatuur bij opslag: | -15 - 50 °C |
Frequentie: | - Hz |
Compatibele besturingssystemen: | Windows, Mac OS X |
Hoogte, in bedrijf: | 0 - 3000 m |
Type koeling: | Actief |
Stekker: | NEMA 5-15P |
Efficientie: | 94 procent |
(Buitenste) hoofdverpakking hoogte: | 221 mm |
(Buitenste) hoofdverpakking breedte: | 508 mm |
(Buitenste) hoofdverpakking brutogewicht: | 23950 g |
(Buitenste) hoofdverpakking lengte: | 594.4 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
Rackcapaciteit: | 2U |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Type beeldscherm: | LED |
Surge energy rating: | 570 J |
Aantal AC uitgangen: | 8 AC-uitgang(en) |
Nominale input voltage: | 120 V |
Stopcontacttypes: | NEMA 5–15R |
Aantal fases: | 1 |
Output power capacity: | 1.5 kVA |
Ingang operation voltage (min): | - V |
Ingang operation voltage (max): | - V |
Uitgang operation voltage (min): | - V |
Uitgang operation voltage (max): | - V |
UPS-topologie: | Line-interactive |
Aantal input fases: | 1 |
Typische backup tijd op halve lading: | 17.7 min |
Typische backup tijd op volledige lading: | 6.5 min |
Hot-swap batterij: | Ja |
Netspanning, in bedrijf: | 120 V |
Emergency Power Off (EPO): | Ja |
EMI/RFI geluidsfiltering: | Ja |
Golfvorm: | Sinus |
Koude start: | Ja |
Automatic Voltage Regulation (AVR): | Ja |
Automatische batterij test: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SmartPro SMC15002URM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024