Tripp Lite SmartPro SMART3000VSTAA Handleiding

Tripp Lite UPS SmartPro SMART3000VSTAA

Lees hieronder de đź“– handleiding in het Nederlandse voor Tripp Lite SmartPro SMART3000VSTAA (32 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
1
Owner’s Manual
1111 W. 35th Street Chicago, IL 60609 USA
www.tripplite.com/support
Important Safety Instructions 2
Quick Installation 3
Basic Operation 5
Storage & Service 10
Specifications 11
SmartPro® VS
Intelligent, Line-Interactive UPS Systems
(Tower Configuration)
• 120V Input • 2200VA - 3000VA Capacities
• Extended-Run Options
Not suitable for mobile applications.
Copyright © 2012 Tripp Lite. All rights reserved. SmartPro
®
is a registered trademark of Tripp Lite.
Español 12
Français 23
Optional Installation 4
Warranty
Registration:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
201112099 931874.indb 1 12/28/2011 4:44:05 PM
2
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct
sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
• Do not install the UPS near magnetic storage media, as this may result in data corruption.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner
will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered under
warranty.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself;
this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground
connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean,
filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can reasonably be
expected to cause the failure of the life support equipment or to significantly affect its safety or
effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This might overload
the UPS and may affect the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason except battery
replacement. There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe
proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not
short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing
battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the
UPS. Battery replacement should be performed only by authorized service personnel using the same
number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local
codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling
information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges
(R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the
specific replacement battery for your UPS.
• If your UPS model is equipped with an external battery connector, only connect Tripp Lite battery
packs of the appropriate type and correct voltage. Do not connect or disconnect external batteries
while the UPS is operating from battery.
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems.
201112099 931874.indb 2 12/28/2011 4:44:05 PM
3
Quick Installation
1 Plug the UPS into an outlet
on a dedicated circuit.*
NOTE! after you plug the UPS into a live AC
outlet, the UPS will automatically charge its
batteries,** but will not supply power to its outlets
until it is turned ON (see Step 3 below).
* See Specifications for circuit amperage requirements. **
The BATTERY CHARGE LED will be the only LED
illuminated.
2
Plug your equipment into
the UPS.*
* Your UPS is designed to only support computer
equipment. You will overload the UPS if the total VA
ratings for all the equipment you connect exceeds the
UPS’s Output Capacity (see Specifications). To find your
equipment’s VA ratings, look on their nameplates. If the
equipment is listed in amps, multiply the number of amps
by 120 to determine VA. (Example: 1 amp Ă— 120 = 120
VA). If you are unsure if you have overloaded the UPS’s
outlets, see “OUTPUT LOAD LEVEL” LED description.
3
Turn the UPS ON.
Press and hold the “POWER” button for one
second. The alarm will beep once briefly after one
second has passed. Release the button.
Note: UPS system will function properly upon initial
startup; however, maximum runtime for the unit’s battery
will only be accessible after it has been charged for 24
hours.
1
2
3
SMART2200VSXL shown
SMART2200VSXL shown
201112099 931874.indb 3 12/28/2011 4:44:06 PM


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: SmartPro SMART3000VSTAA

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite SmartPro SMART3000VSTAA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Tripp Lite

Handleiding UPS

Nieuwste handleidingen voor UPS