Owner’s Manual
SmartPro® SLT
Intelligent, Line-Interactive UPS Systems
100/110/120V Input/Output • Sine Wave Output
Models:
Not suitable for mobile applications.
Important Safety Instructions 2
Quick Installation 3
Optional Installation 4
Basic Operation 4
Battery Replacement 9
Product Registration 10
Storage & Service 10
Español 12
Français 23
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com
Copyright © 2016 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
SMART1050SLT,
SMART1050SLTAA
(Series No. AGSM5384)
SMART1500SLT
(Series No. AGSM7136)
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
16-02-272-932442.indb 1 2/18/2016 4:55:06 PM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed
these warnings may affect your warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive
contaminants, dust or direct sunlight.
• For best performance, keep the indoor temperature between between 32º F and
104Âş F (0Âş C and 40Âş C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the
UPS into itself; this will damage the UPS.
• Be sure to use the proper overcurrent protection for the installation, in accordance
with the plug/equipment rating.
• Do not modify the UPS's plug, and do not use an adapter that would eliminate the
UPS’s ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended. Do not use this
equipment in the presence of a flammable anesthetic mixture with air, oxygen or
nitrous oxide.
• Do not connect surge protectors or extension cords to the output of your UPS.
This might damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Batteries can present a risk of electrical shock and burn from high short-circuit
current. Observe proper precautions. There are no user-serviceable parts inside the
UPS. Do not open the UPS except to perform battery replacement. Do not open
batteries. Do not short or bridge the battery terminals with any object. Unplug and
turn off the UPS before performing battery replacement. Use tools with insulated
handles. Battery replacement should be performed only by authorized service personnel
using the same number and type of batteries (Sealed Lead-Acid). Do not dispose of
the batteries in a fire. The batteries are recyclable. Refer to your local codes for
disposal requirements or visit http://www.tripplite.com/support/recycling-program
for recycling information. Tripp Lite offers a complete line of UPS System
Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at
www.tripplite.com/support/battery/index.cfm to locate the specific replacement
battery for your UPS.
Important Safety Instructions
16-02-272-932442.indb 2 2/18/2016 4:55:07 PM
3
1 With the UPS disconnected from utility
power, use a small tool to set the
Voltage Dip Switch to match your input
voltage. (All models are preset to the
120V setting.)
2 Plug the UPS into an outlet on a
dedicated circuit.
NOTE! after you plug the UPS into a live AC
outlet, the UPS will automatically charge its
batteries,* but will not supply power to its
outlets until it is turned ON.
* The BATTERY CHARGE LED will be the only LED
illuminated
3 Plug your equipment into the UPS.
All outlets provide battery backup and surge
protection for computers, monitors and other
critical devices.
Do not plug high-draw equipment such as
laser printers into the battery backup/
surge protection outlets.
Note: Your UPS is designed to support electronic
equipment only. You will overload the UPS if the total VA
rating for all equipment connected through the battery
backup/surge protection outlets exceeds the UPS's
Output Capacity. To find your equipment's VA ratings, look
on their nameplates. If the equipment is listed in amps,
multiply the number of amps by 120 to determine VA.
(Example: 1 amp Ă— 120 = 120 VA). If you are unsure if
you have overloaded the UPS's outlets, see “OUTPUT
LOAD LEVEL” LED description.
4 Turn the UPS ON.
Press and hold the “STANDBY” button for one
second. The alarm will beep once briefly after
one second has passed. Release the button.
1
3
Quick Installation
2
4
16-02-272-932442.indb 3 2/18/2016 4:55:10 PM


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: SmartPro SMART1050SLTAA
Kleur van het product: Zwart
Gewicht: 16300 g
Breedte: 171 mm
Diepte: 337 mm
Hoogte: 260 mm
Snoerlengte: 1.8 m
LED-indicatoren: Ja
Vormfactor: Tower
Certificering: TAA\nUL1778
Interface: USB; DB9
Uitgangsvermogen: 650 W
Accu/Batterij oplaadtijd: 6 uur
Temperatuur bij opslag: -15 - 50 °C
Stroomspanning bescherming: Over voltage,Under voltage
Frequentie: 50/60 Hz
Luchtvochtigheid bij opslag: 0 - 95 procent
Power factor: 0.6
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Type batterij: RBC24-SLT
Surge energy rating: 690 J
Aantal AC uitgangen: 8 AC-uitgang(en)
Nominale input voltage: 120 V
Stopcontacttypes: NEMA 5–15R
Golf protectie functies: Network,Telephone
Output power capacity: 1.05 kVA
Ingang operation voltage (min): 83 V
Ingang operation voltage (max): 145 V
Uitgang operation voltage (min): 120 V
Uitgang operation voltage (max): 120 V
Typische backup tijd op halve lading: 19 min
Typische backup tijd op volledige lading: 7 min
Hot-swap batterij: Ja