1
Ownerās Manual
Smart and OmniSmartĀ®
Medical-Grade UPS Systems
Models:
OMNISMART350HG
(Series Number: AGOM350KSR57HG)
Important Safety Instructions 2
Package Contents 5
Quick Installation 6
Basic Operation 8
Guidance and Manufacturerās Declaration 14
Storage & Service 15
Regulatory Compliance & 16
Product Registration
EspaƱol 17
FranƧais 33
1111 W. 35th Street, Chicago, IL 60609 USA ā¢ www.tripplite.com/support
Copyright Ā© 2015 Tripp Lite. All rights reserved.
SMART700HG
(Series Number: AGSM700PSR3HG)
SMART1200XLHG
(Series Number: AGSM1200PSR3HG)
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protectorā
a $100 value!
www.tripplite.com/warranty
15-11-178-9332C2.indb 1 12/4/2015 9:20:10 AM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings may affect
your warranty.
Statement of Intended Use
Tripp Lite Medical-Grade UPS Systems are intended to support and protect non-medical and
medical computer equipment and medical devices that require leakage current reduction, surge
protection, voltage regulation, line noise ļ¬ltering and battery backup during power outages and
generator testing, both inside and outside patient care areas. Tripp Liteās Medical-Grade UPS
Systems come with hospital-grade plugs and receptacles that reduce leakage to below 100Ī¼A.
Product Information
AGOM350KSR57HG AGSM700PSR3HG AGSM1200PSR3HG
AC Input Voltage 120 120 120
AC Input Voltage Range 83ā147 81ā143 81ā143
Input Amp(s) 2.3 5.5 9.2
Output Amps(s) 1.9 5.8 6.25
Rated Power (VA/Watts) 330VA/225W 700VA/450W 1000VA/750W
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
No. of Phases Single Single Single
Class Type Class I Class I Class I
Plug/Connector Type NEMA 5-15P NEMA 5-15P NEMA 5-15P
Operation Continuous Continuous Continuous
AC Input Protection (Qty./type/rating) Input breaker
(2 x 3.5A), thermal
Input breaker
(2 x 10A), thermal
Input breaker
(2 x 15A), thermal
Max Leakage Current (uA) Less than 100uA Less than 100uA Less than 100uA
Weight 25.0 lbs 44.2 lbs 46.4 lbs
Known Contraindication None None None
UPS Location Warnings
Relevant Symbols
Denotes that information in the manual should be reviewed before use.
Used to signal a warning that a statement is particularly important and could pose a safety
risk.
Warning-Dangerous Voltage No sitting
Denotes general warning sign No stepping on surface
Refer to Instruction Manual/Booklet No pushing
15-11-178-9332C2.indb 2 12/4/2015 9:20:10 AM
3
Important Safety Instructions continued
ā¢ Do not use this equipment within oxygen-enriched atmospheres, or within 0.3 m (1 ft.) of a point
at which an oxygen-enriched atmosphere is intentionally vented.
ā¢ Use caution when lifting UPS. Because of the considerable weight of all UPS systems, at least
two people should assist in lifting and installing them.
ā¢ Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
ā¢ For best performance, the UPS should be used in a location that meets the following conditions:
Temperature: 0 to 40Ā° C (32 to 104Ā° F); Humidity: 0 to 95% (non-condensing);
Elevation: <6,562 ft. (2,000 m) above sea level; Pressure: >95kPa
ā¢ Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents
or fan openings.
ā¢ Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner
will seriously inhibit the unitās internal cooling, eventually causing product damage not covered
under warranty.
ā¢ UPS is not intended for patient contact. Avoid installation that will cause accidental contact of
patients.
UPS Connection Warnings
ā¢ The UPS contains its own energy source (battery). The output terminals may be live even when
the UPS is not connected to an AC supply.
ā¢ Connect your UPS to a properly grounded AC power outlet. Do not modify the UPSās plug in a
way that would eliminate the UPSās connection to ground. Do not use adapters that eliminate the
UPSās connection to ground.
ā¢ Do not plug your UPS into itself; this will damage the UPS and void your warranty.
ā¢ If you are connecting your UPS to a motor-powered AC generator, the generator must provide
ļ¬ltered, frequency-regulated output.
ā¢ To remove the UPS from the supply mains, the plug serves as a disconnect device.
ā¢ Once connected, do not limit access to the input plug. The plug must be accessible to be used as
a means of disconnection.
ā¢ When connecting your UPS to the power outlet, ensure that the power outlet is provided with
suitable overcurrent protection in accordance with your national and local electrical codes. Ensure
that the overcurrent protection has a minimum of 1500A breaking capacity.
CAUTION: Do not remove cover for 5 minutes after disconnecting all sources of
supply. Risk of electric shockāhazardous live parts inside. Do not remove cover.
No user serviceable parts inside. Refer servicing to qualiļ¬ed service personnel.
This UPS receives power from more DC sources; disconnection of the AC and DC
source is required to de-energize the unit before servicing.
CAUTION: To ensure proper grounding with supply mains power, the input cord must
be connected with an approved country-speciļ¬c plug with a protective earth ground
connection.
CAUTION: If this product is operated on battery (not connected to mains power),
adequate safeguards should be employed to protect against accidental contact
with AC power conductors.
CAUTION: Do not exceed total rated output.
WARNING: No modiļ¬cation of this equipment is allowed.
15-11-178-9332C2.indb 3 12/4/2015 9:20:10 AM
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | SmartPro |
Kleur van het product: | Zwart |
Gewicht: | 7400 g |
Breedte: | 439.9 mm |
Diepte: | 286 mm |
Hoogte: | 43.9 mm |
Gewicht verpakking: | 8030 g |
Breedte verpakking: | 401.3 mm |
Diepte verpakking: | 533.4 mm |
Hoogte verpakking: | 106.7 mm |
LED-indicatoren: | Ja |
Vormfactor: | Rackmontage |
Land van herkomst: | China |
Aantal USB 2.0-poorten: | 1 |
Certificering: | CE, GOST, SASO, IRAM |
Geluidsalarm(en): | Ja |
Responstijd: | 4 ms |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 300 W |
Accu/Batterij oplaadtijd: | 4 uur |
Temperatuur bij opslag: | -15 - 50 Ā°C |
Frequentie: | - Hz |
Seriƫle poort(en): | 1 |
Stekker: | C14 stekker |
Efficientie: | 95 procent |
(Buitenste) hoofdverpakking hoogte: | 254 mm |
(Buitenste) hoofdverpakking breedte: | 408.9 mm |
(Buitenste) hoofdverpakking brutogewicht: | 17460 g |
(Buitenste) hoofdverpakking lengte: | 551.2 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 2 stuk(s) |
Bedrijfstemperatuur (T-T): | 0 - 40 Ā°C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: | 10037332119251 |
Surge energy rating: | 480 J |
Aantal AC uitgangen: | 7 AC-uitgang(en) |
Stopcontacttypes: | C13 stekker |
Output power capacity: | 0.5 kVA |
Ingang operation voltage (min): | 230 V |
Ingang operation voltage (max): | 230 V |
Uitgang operation voltage (min): | 220 V |
Uitgang operation voltage (max): | 240 V |
Typische backup tijd op halve lading: | 14.6 min |
Typische backup tijd op volledige lading: | 3.2 min |
Hot-swap batterij: | Ja |
Emergency Power Off (EPO): | Ja |
Spanningsbeveiliging: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SmartPro stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024