1
Owner’s Manual
SmartOnline® 208V SV-Series
3-Phase Modular UPS Systems
(Series Number: AG-0172) (Series Number: AG-0173) (Series Number: AG-0174)
Input: 120/127V (Ph-N), 208/220V (Ph-Ph)
(Not suitable for mobile applications)
Español 37 • Français 73
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2017 Tripp Lite. All rights reserved.
2
Table Of Contents
1. Introduction 3
2. IMPORTANT SAFETY WARNINGS 4
2.1 Location Warning 4
2.2 EMC 4
2.3 Connection Warning 4
2.4 Battery Warning 5
2.5 Safety Standards 5
3. UPS Layout 6
3.1 SmartOnline SV-Series Layout 6
3.2 Package Contents 8
4. Positioning and Pre-Installation 9
4.1 Important Safety Warning 9
4.2 Transportation 9
4.3 Delivery 9
4.4 Installation Environment 9
4.5 Unpacking the UPS 10
5. Wiring and Block Diagrams 11
5.1 Block Diagram 11
5.2 Function of Core System Elements 11
6. Operating Overview 12
6.1 Operating Modes 12
6.2 Single or Dual Feed Input 12
7. Installation 13
7.1 Breakers and Wiring Terminal Block 13
7.2 STS Module Installation 13
7.2.1 Installing a Power Module 15
7.2.2 Removing a Power Module 16
7.2.3 Installing a Battery Module 16
7.2.4 Removing a Battery Module 16
7.2.5 External Battery Cabinet Connection 17
7.3 Cold Start 17
8. Manual Maintenance Bypass 18
8.1 Transfer to Bypass via STS Module Connector 18
from UPS Mode
8.2 Transfer to Bypass via Control Panel 18
9. Control Panel 19
9.1 Introduction 19
9.2 Audible Alarms 20
9.3 Screen Descriptions 20
9.3.1 Start-Up Screen 20
9.3.2 Home Screen 20
9.3.3 Menu Screen 20
9.3.4 Control Screen 21
9.3.5 Measurement Screen 22
9.3.6 Setup Screen 23
9.3.6.1 General 23
9.3.6.2 System 24
9.3.6.3 Battery 25
9.3.6.4 Pre-Alarm 26
9.3.7 Information Screen 26
9.3.8 Events Screen 27
9.3.8.1 Current Events 27
9.3.8.2 Historical Events 28
9.3.8.3 Reset All Events 28
9.4 Text Summaries and Explanations 28
10. Communication 30
10.1 STS Module 30
10.2 Dry Contact Ports 30
10.2.1 Remote EPO Input Port 30
10.2.2 Maintenance Bypass Switch Port 31
10.3 Connectivity 31
10.3.1 SNMP 31
10.3.2 Serial Port 31
10.3.3 USB Port 31
11. Maintenance 32
11.1 Power Module Replacement 32
11.2 Battery Module Replacement 32
11.3 Installing/Replacing the Air Filters 32
12. Troubleshooting 33
13. Technical Specifications 34
14. UPS and Battery Storage; Battery Disposal 36
14.1 UPS and Battery Storage 36
14.2 Battery Disposal 36
15. Warranty and Product Registration 36
3
1. Introduction
Tripp Lite’s SmartOnline SV-Series Uninterruptible Power Supply (UPS) is a Voltage and Frequency Independent (VFI) true on-line, double
conversion 3-Phase UPS system. This UPS continuously conditions the incoming electrical power supply, eliminating power fluctuations and
interruptions that can otherwise damage sensitive electronic devices and create system downtime. Ranging from 20kVA/18kW to 140kVA/126kW,
this series of UPS systems is designed to the highest quality and performance standards and offers the following features:
• True on-line UPS: highest level of UPS protection, fully regulating the incoming power supply and transferring immediately to battery in the
event of an extended mains failure for continuous support of critical loads
• Modular system: three frame arrangements with multiple construction possibilities to suit specific application requirements; easy and fast
maintenance with hot-swappable power and battery modules
• N+1 redundancy up to 140kVA
• High efficiency – lower heat losses reduce cooling costs and extend system lifespan
• 0.9 output power factor – more actual power allows more equipment to be supported
• Automatic and manual bypass increase system reliability and allow for maintenance without removing power from the attached load
• Wide input voltage window – the UPS system regulates even poor-quality incoming power without reverting to battery, maximizing system
uptime and protecting battery life
• Compact form factor; space-saving design even up to 140kVA in a standard rack footprint
• Serial communication as standard; SNMP and volt free contact options for optimum configurability
• Dual input design allows standard installation from one or two power sources
• Low input current total harmonic distortion; no need to oversize a generator set
The SmartOnline SV UPS is designed for protecting critical electrical equipment for:
• Data centers
• Telecommunications
• Networks (LAN/WAN)
• Corporate infrastructure
• Healthcare
• Security
• Light industrial
• Financial institutions
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | SmartOnline SV40KM2P2B |
Kleur van het product: | Zwart |
Gewicht: | 274290 g |
Breedte: | 106.9 mm |
Diepte: | 766.8 mm |
Hoogte: | 2009.9 mm |
Geluidsniveau: | 73 dB |
Gewicht verpakking: | 335500 g |
Breedte verpakking: | 294.9 mm |
Diepte verpakking: | 870 mm |
Hoogte verpakking: | 2174.7 mm |
Gebruikershandleiding: | Ja |
Materiaal behuizing: | Staal |
LED-indicatoren: | Ja |
Vormfactor: | Tower |
Land van herkomst: | China |
Soort serieële aansluiting: | RS-232 |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 36000 W |
Temperatuur bij opslag: | -15 - 60 °C |
Frequentie: | 40 - 70 Hz |
Web-gebaseerd management: | Ja |
Hoogte, in bedrijf: | 0 - 1000 m |
Power factor: | 0.9 |
Type koeling: | Actief |
Stekker: | Eindstation |
Efficientie: | 92 procent |
(Buitenste) hoofdverpakking hoogte: | 249.9 mm |
(Buitenste) hoofdverpakking breedte: | 294.9 mm |
(Buitenste) hoofdverpakking brutogewicht: | 34930 g |
(Buitenste) hoofdverpakking lengte: | 870 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Type beeldscherm: | LCD |
Surge energy rating: | 2496 J |
Stopcontacttypes: | Eindstation |
Stroom (max.): | 120 A |
Output power capacity: | 40 kVA |
Ingang operation voltage (min): | 120 V |
Ingang operation voltage (max): | 220 V |
Uitgang operation voltage (min): | 120 V |
Uitgang operation voltage (max): | 220 V |
Crest factor: | 3:1 |
UPS-topologie: | Dubbele conversie (online) |
Aantal input fases: | 3 |
Typische backup tijd op halve lading: | 8 min |
Typische backup tijd op volledige lading: | 3.9 min |
Hot-swap batterij: | Ja |
Seriële interface: | Ja |
Hoorbare alarmstanden: | Alarm when on battery, Fault, Low battery alarm |
Emergency Power Off (EPO): | Ja |
Output voltage THD: | 1.5 procent |
Input vermogensfactor: | 0.99 |
Uitgangsspanningsregeling: | 1 procent |
Aantal output fases: | 3 |
EMI/RFI geluidsfiltering: | Ja |
Spanningsbeveiliging: | Ja |
Golfvorm: | Sinus |
Input stroom THD: | 3 procent |
Noodstop-aansluiting (EPO): | Ja |
Koude start: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SmartOnline SV40KM2P2B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024