Pagina 1/80
SU3000RTXLCD2U Quick
Start Guide—
Page 8
1
Owner’s Manual
SmartOnline®
Single-Phase Rackmount Online UPS System
with Built-in LCD Monitoring & Control Screen
Not suitable for mobile applications.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright ©2013 Tripp Lite. All rights reserved. SmartOnline
® is a trademark of Tripp Lite. For latest updates, please visit www.tripplite.com
1. Overview 2
Parts List 2
Additional Accessories 2
Model Specific Accessories 2
2. Important Safety Instructions 3
3. Installation 4
Rack Mounting 4
Tower Mounting 5
4. Features 6
Front Panel Controls 6
Rear Panel Features 7
5. Basic Connection and Start-Up 8
Quick Start Guide 8
Optional Connections 9
6. Operation 11
Modes of Operation 11
LCD Informational Screens 14
UPS Setup Overview 16
Using PowerAlert Software 16
Using the LCD interface 16
7. Troubleshooting 23
8. Internal Battery Replacement 24
9. Storage and Service 26
10. Warranty Registration 26
Español 27
Français 53
Warranty
Registration:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
NOTE: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software.
See page 20 for more information if you are connecting external batteries to this UPS.
13-07-015-9332C3.indb 1 7/26/2013 11:16:06 AM
2
Overview
Tripp Lite SmartOnline Rackmount UPS Systems with interactive LCD interface feature on-line, double-conversion UPS protection with
full-time sine wave output and zero transfer time suitable for all advanced networking applications. Each system provides long running
battery support with optional extended-run and SNMP/Web communications ability. Built-in interfaces include USB, DB9 serial and
Emergency Power Off (EPO). The interactive front panel LCD screen provides detailed UPS status, preset and control options. An optional
economy mode setting reduces power consumption and BTU heat output.
Parts List
UPS System Bolt-on mounting ears (2) 4-post rail kit PowerAlert CD
USB Cable EPO (RJ11) Cable RS-232 Cable Owner’s manual
Additional Accessories (Optional)
•SNMPWEBCARD:InternalnetworkinterfacecardforSNMP/Webcontrolandmonitoring
•ENVIROSENSE:Temperature/HumiditysensorforusewithSNMPWEBCARD
•SRSWITCH:RackdoorsensorforusewithENVIROSENSEandSNMPWEBCARD
•RELAYIOCARD:ProgrammableRelayI/OCardforremoteUPSmonitoring
•2-9USTAND:SupportsrackmountUPSandbatterypacksinuprighttowerconfiguration(notforSU3000RTXLCD3U)
Model Specific Accessories (Optional)*
UPS Model SU3000RTXLCD2U
External Battery Packs (LIMIT 1)** BP72V15-2U
External Battery Packs (NO LIMIT)** BP72V28RT3U
Hot-swap PDU System PDUB30
2 Post Rackmount Kit 2POSTRMKITWM
5 Year Extended Warranty WEXT5-2200-3000
*VisitthespecificationpageforyourUPSsystematwww.tripplite.comfordetailedextendedruntimedataandadditionalaccessoryoptions.
** Note: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software. See page 20 for
more information if you are connecting external batteries to this UPS.
13-07-015-9332C3.indb 2 7/26/2013 11:16:08 AM
3
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all
Tripp Lite UPS Systems. Failure to heed these warnings may affect your warranty.
UPS Location Warnings
•InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,dustordirectsunlight.
•Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand40ºC).
•LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit’s internal cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
•ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.DonotplugtheUPSintoitself;thiswilldamagetheUPS.
•DonotmodifytheUPS'splug,anddonotuseanadapterthatwouldeliminatetheUPS’sgroundconnection.
•DonotuseextensioncordstoconnecttheUPStoanACoutlet.YourwarrantywillbevoidedifanythingotherthanTrippLitesurge
suppressors are used to connect your UPS to an outlet.
•IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormust
provide clean, filtered, computer-grade output.
•ThemainssocketoutletthatsuppliestheUPSshouldbeneartheUPSandbeeasilyaccessible.
•ToremoveACvoltagefromtheUPS,pulltheplugfromthesocketoutlet.
Equipment Connection Warnings
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureof
the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
•DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.ThismightdamagetheUPSandmayaffectthesurge
suppressor and UPS warranties.
•ConnecttheUPStoanoutletthatisadequatelyprotectedagainstexcesscurrents,shortcircuitsandearthfaults,aspartofthe
building installation. The outlet protection for the UPS should be in series with the mains input.
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observeproperprecautions.Donotdisposeofthe
batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The
batteries are recyclable. Refer to your local codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling
information.TrippLiteoffersacompletelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteontheWebatwww.
tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.
•Note:ExternalbatterypackoptionsrequireconfigurationusingfrontpanelLCDinterfaceorviaTrippLite’sEXTERNALBATTERY
CONFIGURATION software. See page 20 for more information if you are connecting external batteries to this UPS.
13-07-015-9332C3.indb 3 7/26/2013 11:16:09 AM
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | SmartOnline SU3000RTXLCD2U |
Kleur van het product: | Zwart |
Gewicht: | 31980 g |
Breedte: | 439.4 mm |
Diepte: | 647.7 mm |
Hoogte: | 86.4 mm |
Snoerlengte: | 3 m |
Geluidsniveau: | 50 dB |
Gewicht verpakking: | 41730 g |
Breedte verpakking: | 612.1 mm |
Diepte verpakking: | 1003.3 mm |
Hoogte verpakking: | 231.1 mm |
Materiaal behuizing: | Staal |
LED-indicatoren: | Ja |
Vormfactor: | Rackmontage |
Land van herkomst: | China |
Certificering: | UL1778\r\nCSA\r\nFCC |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 2700 W |
Temperatuur bij opslag: | -15 - 50 °C |
Frequentie: | 50/60 Hz |
Luchtvochtigheid bij opslag: | 0 - 95 procent |
Hoogte, in bedrijf: | 0 - 3000 m |
Power factor: | 0.9 |
Type koeling: | Actief |
Stekker: | NEMA L5-30P |
Efficientie: | 99 procent |
(Buitenste) hoofdverpakking hoogte: | 231.1 mm |
(Buitenste) hoofdverpakking breedte: | 612.1 mm |
(Buitenste) hoofdverpakking brutogewicht: | 41730 g |
(Buitenste) hoofdverpakking lengte: | 1003.3 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 1 stuk(s) |
Rackcapaciteit: | 2U |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Type beeldscherm: | LCD |
Type batterij: | BP72V15-2U, BP72V28RT-3U, BP72V18-2US |
Surge energy rating: | 570 J |
Aantal AC uitgangen: | 9 AC-uitgang(en) |
Nominale input voltage: | 120 V |
Stopcontacttypes: | NEMA 5–15R, NEMA L5-30R |
Stroom (max.): | 24 A |
Output power capacity: | 3 kVA |
Ingang operation voltage (min): | 100 V |
Ingang operation voltage (max): | 127 V |
Uitgang operation voltage (min): | 100 V |
Uitgang operation voltage (max): | 127 V |
Crest factor: | 3:1 |
UPS-topologie: | Dubbele conversie (online) |
Aantal input fases: | 1 |
Typische backup tijd op halve lading: | 11.3 min |
Typische backup tijd op volledige lading: | 4.1 min |
Hot-swap batterij: | Ja |
Netspanning, in bedrijf: | 120 V |
Emergency Power Off (EPO): | Ja |
Uitgangsspanningsregeling: | 2 procent |
EMI/RFI geluidsfiltering: | Ja |
Golfvorm: | Sinus |
Koude start: | Ja |
Output-aansluitingen: | 4 x 5-15R & 4 x 5-15/20R &1 x L5-30R |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SmartOnline SU3000RTXLCD2U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024