Tripp Lite SmartOnline Handleiding
Tripp Lite
UPS
SmartOnline
Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite SmartOnline (16 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/16
Owner’s Manual
1111 W. 35th Street Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • www.tripplite.com
Important Safety Instructions 2
Installation 3
Basic Operation 6
Battery Replacement 12
Storage and Service 14
SmartOnlineâ„¢
Rack/Tower Mount Online UPS Systems
Specifications 14
Español
Français 31
16
Copyright ©2002 Tripp Lite. All rights reserved. SmartOnline
â„¢ is a trademark of Tripp Lite.
Troubleshooting 10
PyccŞèé 46
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between between 32º F and 104º F
(0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the
UPS into itself; this will damage the UPS.
• Do not modify the UPS's plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be
voided if anything other than Tripp Lite surge suppressors are used to connect your UPS
to an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support applications in which a malfunction
or failure of a Tripp Lite UPS System could cause failure or significantly alter the
performance of a life-support device.
• Do not connect surge suppressors or extension cords to the output of your UPS. This
might damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason
except battery replacement. There are no user-serviceable parts inside.
• Battery replacement must be performed by qualified service personnel. Because the
batteries present a risk of electrical shock and burn from high short-circuit current,
observe proper precautions. Unplug and turn off the UPS before performing battery
replacement. Use tools with insulated handles, and replace the existing batteries with the
same number and type of new batteries (Sealed Lead-Acid). Do not open the batteries.
Do not short or bridge the battery terminals with any object.
• The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in
the USA only call 1-800-SAV-LEAD for recycling information. Do not dispose of the
batteries in a fire.
• Only connect Tripp Lite battery packs of the appropriate type and correct voltage to the
external battery connector.
• Do not connect or disconnect external batteries while the UPS is operating from battery.
• Do not operate your UPS without batteries.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these
warnings will void your warranty.
2
Important Safety Instructions
Rackmount
1) Loosen the wingnuts on each of the two UPS
Side Supports; adjust the length of the supports to
match the depth of your rack; tighten wingnuts.
2) Mount both UPS Side Supports in your rack on
the inside surfaces of the rack rails.
Note: Both support ledges should face inward. The side supports’
front and back holes are threaded and do not require nuts to
secure rack bolts.
3) Attach mounting ‘ears’ to the front end of the
UPS’s sides using the screws provided.
4) Lift UPS and slide it onto the UPS Side
Supports within your rack. Mount the UPS by
screwing rack bolts through the UPS mounting
‘ears’, through the rack rails and through the UPS
Side Supports.
Note: The side supports’ front holes are threaded and do not
require nuts to secure rack bolts.
Vertical Tower Mount
1) Cover the rackmount screw holes on the UPS’s
sides with supplied snap-in hole-cover caps.
2) Place the UPS upright in a flat, stable location
with its control panel on the high corner facing
forward. Position stabilizer feet 4 in. from each
end of the UPS.
Mounting
SU2200RTXL2U shown
SU2200RTXL2U shown
3
Installation
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | SmartOnline |
Kleur van het product: | Zwart |
Gewicht: | 21600 g |
Gewicht verpakking: | 27100 g |
LED-indicatoren: | Ja |
Vormfactor: | Rackmontage |
Afmetingen verpakking (BxDxH): | 514 x 584 x 230 mm |
Aantal USB 2.0-poorten: | 1 |
Certificering: | CE, SASO |
Geluidsalarm(en): | Nee |
Uitgangsvermogen: | 1600 W |
Accu/Batterij oplaadtijd: | 6 uur |
Temperatuur bij opslag: | -15 - 50 °C |
Mac-compatibiliteit: | Ja |
Afmetingen (B x D x H): | 89 x 483 x 444 mm |
Seriële poort(en): | 1 |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Surge energy rating: | 660 J |
Input-connectietype: | C 20 |
Output power capacity: | 2.2 kVA |
Typische backup tijd op halve lading: | 14 min |
Typische backup tijd op volledige lading: | 5 min |
Hot-swap batterij: | Ja |
Emergency Power Off (EPO): | Ja |
Output-aansluitingen: | 4 x C13\n2 x C19 |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite SmartOnline stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024