Owner’s Manual
Metered Rack PDU
Models: PDUV30HV, PDUMV30, PDUMV16HV,
PDUMV20HV, PDUMV30HV
(Series Number: AGIB6672, AGPD6673, AGPD6674, AGPD6675)
Español 6 • Français 11 • Русский 16 • Deutsch 21
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
18-11-318-933312.indb 1 3/20/2019 1:22:51 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will void
the product warranty.
Important Warnings
The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or
line noise protection for connected equipment.
The PDU is designed for indoor use only, in a controlled environment, away from
excess moisture, temperature extremes, conductive contaminants, dust or direct
sunlight.
The PDU must be installed by a qualied technician only.
Do not attempt to mount the PDU to an insecure or unstable surface.
Install in accordance with National Electrical Codes. Be sure to use the proper over
current protection for the installation, in accordance with the plug rating/equipment
rating as follows:
Model Series Number Overcurrent Protection
PDUV30HV AGIB6672 30A
PDUMV30 AGPD6673 30A
PDUMV16HV, PDUMV20HV AGPD6674 20A
PDUMV30HV AGPD6675 30A
Short-circuit backup protection and overcurrent protection is provided by the building
installation.
The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
Do not connect the PDU to an ungrounded outlet or to extension cords or adapters
that eliminate the connection to ground.
The plug on the power supply cord is intended to serve as the disconnect device.
Be sure that the socket-outlet is installed near the equipment and is made easily
accessible.
Never attempt to install electrical equipment during a thunderstorm.
The power requirement for each piece of equipment connected to the PDU must not
exceed the individual outlet’s load rating.
The total power requirement for equipment connected to the PDU must not exceed the
maximum load rating for the PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
Do not attempt to use the PDU if any part of it becomes damaged.
18-11-318-933312.indb 2 3/20/2019 1:22:51 PM
3
Important Safety Instructions
Installation
Note: The user must determine the fitness of hardware and procedures before mounting. The PDU and included
hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications.
1A 0U Rack Configuration (Mounting
Brackets). Prior to installation,
determine the rack location in which
the PDU is to be installed. Attach the
mounting brackets to the back of the
PDU as shown, using the included
screws. To assist with proper positioning,
the brackets have four screw holes each;
make sure that the same two holes are
used to attach each bracket to the PDU.
After attaching the brackets, position the
PDU in the rack and mount it by installing
four user-supplied screws through the
brackets into the rack.
1B 0U Rack Configuration (Mounting
Buttons). Attach the included mounting
buttons to the PDU. Position the PDU as
desired in the rack enclosure, align the
buttons with the rack mounting slots,
and slide the PDU into position.
1C Under-Counter Configuration. The PDU
may be installed under a counter using
the included mounting brackets. Attach
the mounting brackets to the back of
the PDU as shown in STEP 1A. Secure
the PDU to the underside of the counter
by installing two user-supplied screws
through each bracket into the counter.
1B
1C
1A
Use of this equipment in life support applications where failure of this equipment
can reasonably be expected to cause the failure of the life support equipment or to
signicantly affect its safety or effectiveness is not recommended.
18-11-318-933312.indb 3 3/20/2019 1:22:51 PM


Product specificaties

Merk: Tripp Lite
Categorie: Stekkerdoos
Model: PDUMV16HV
Kleur van het product: Zwart
Gewicht: 2410 g
Breedte: 57.2 mm
Diepte: 95.2 mm
Hoogte: 1619.2 mm
Snoerlengte: 3 m
Gewicht verpakking: 3580 g
Breedte verpakking: 129.5 mm
Diepte verpakking: 1661.2 mm
Hoogte verpakking: 73.7 mm
Materiaal behuizing: Metaal
LED-indicatoren: Ja
Beeldscherm: LED
Land van herkomst: China
Afmetingen verpakking (BxDxH): 76 x 127 x 1648 mm
Certificering: IEC 60950-1, GOST
Duurzaamheidscertificaten: RoHS
Afmetingen (B x D x H): 57 x 95 x 1620 mm
Montage: Verticaal
Stekker: IEC309
(Buitenste) hoofdverpakking hoogte: 177.8 mm
(Buitenste) hoofdverpakking breedte: 419.1 mm
(Buitenste) hoofdverpakking brutogewicht: 23040 g
(Buitenste) hoofdverpakking lengte: 1668.8 mm
Hoeveelheid per (buitenste) hoofdverpakking: 6 stuk(s)
Rackcapaciteit: 0U
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: 10037332182873
Aantal AC uitgangen: 38 AC-uitgang(en)
Nominale input voltage: 200-240 V
Stopcontacttypes: C13 coupler,C19 coupler
Stroom (max.): 16 A
PDU types: Gemeten
Netspanning, in bedrijf: 200-240 V
Output-aansluitingen: 32 x C13 & 6 x C19