Pagina 1/20
Warranty
Registration
Register online today for a chance
to win a FREE Tripp Lite product!
www.tripplite.com/warranty
1
Owner’s Manual
ECO-UPS™ Systems with LCD
Models: ECO650LCD, ECO850LCD
Not suitable for mobile applications
Important Safety Instructions 2
Basic Operation 3
UPS On/Off 3
LCD Features 3
Display Power Conditions 3
ECO Energy-Saving Feature 3
Enable/Disable Alarm 3
LCD Brightness 4
Self-test 4
Error Messages 4
Features 4
Storage and Service 5
Warranty Registration 6
Español 7
Français 13
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2010 Tripp Lite. All rights reserved.
The ECO Energy-Saving Feature allows your UPS to save energy by automatically turning off
designated outlets when your computer is off or in standby mode. When the UPS detects
that your computer has been turned off or in standby mode for 3 minutes, it will turn off the
outlets marked “ECO”. The 3 minute delay ensures that the outlets remain powered during a
reboot, momentary cable disconnection or similar transitory event.
201010198.indb 1 12/21/2010 11:47:34 AM
Important Safety Instructions
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings may
affect the warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F
(0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS
into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be
voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to
an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This might
damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS
or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn
off the UPS before performing battery replacement. Use tools with insulated handles. There
are no user-serviceable parts inside the UPS. Battery replacement should be performed
only by authorized service personnel using the same number and type of batteries (Sealed
Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal
requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling information. Tripp
Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit
Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific
replacement battery for your UPS.
• Do not attempt to add external batteries to the UPS.
201010198.indb 2 12/21/2010 11:47:34 AM
Basic Operation
3
UPS ON/OFF
•PlugtheUPSintoagroundedoutlet.
•TurntheUPSon:Press and hold the button for 2 seconds. The UPS alarm will beep
once briefly after 2 seconds have passed.
•PlugequipmentintotheUPS:Select outlets will provide battery backup and surge
protection; connect your computer, monitor and other critical devices here.* Select outlets
will provide surge protection only; connect your printer and other nonessential devices
here.
•TurntheUPSoff:Press and hold the button for 2.5 seconds. The UPS alarm will
beep once after 2.5 seconds have passed.
* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for
all the equipment you connect to the “Battery, Surge and Noise Protected” outlets exceeds the UPS’s Output
Capacity. To estimate your equipment’s power requirements, look on the nameplates. If the equipment is
listed in amps, multiply the number of amps by 120 to determine VA, (Example: 1 amp x 120 = 120 VA).
Your UPS is fully loaded when the display indicates 100% load.
LCD Features
Tap the button to advance from one display to the next. Use the button to toggle
settings for ECO, Alarm, LCD Brightness and Self-test functions. When the preferred setting
has been selected, continue by pressing the button. If the screen is idle for 20 seconds,
the LCD will return to the home screen, retaining the last selected settings.
Display Power Conditions
Use the button to advance through power conditions.
• Voltage In
• Voltage Out
• Estimated Runtime (in minutes)
• Load %*
• Load Wattage*
• Battery Capacity %
* Display measurement represents battery backup protected outlets only.
ECO Energy-Saving Feature
Use the included USB cable to connect your UPS to your computer. Connect nonessential
equipment to the ECO outlets, marked “ECO” on your UPS system. Make sure that any
devices connected to the ECO outlets can be turned off without interrupting your Internet
connection, local network, or other essential services. While your UPS is turned on and
operating normally from utility power, tap the button repeatedly to advance the LCD
display to the screen marked “ECO”. Use the button to enable the ECO function.
Enable/Disable Alarm
Tap the button repeatedly to advance to the LCD display featuring the icon. Press the
button to select enable or disable alarm mode settings.
201010198.indb 3 12/21/2010 11:47:34 AM
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | ECO650LCD |
Kleur van het product: | Zwart |
Gewicht: | 2200 g |
Breedte: | 279.9 mm |
Diepte: | 150.1 mm |
Hoogte: | 83.3 mm |
Snoerlengte: | 1.8 m |
Gewicht verpakking: | 2540 g |
Breedte verpakking: | 327.7 mm |
Diepte verpakking: | 205.7 mm |
Hoogte verpakking: | 104.1 mm |
LED-indicatoren: | Ja |
Land van herkomst: | China |
Afmetingen verpakking (BxDxH): | 330 x 203 x 108 mm |
Aantal USB 2.0-poorten: | 1 |
Certificering: | UL1778\nCSA\nNOM\nFCC Part 15 Category B\nFCC Part 68 |
Interface: | USB |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 325 W |
Temperatuur bij opslag: | -15 - 50 °C |
Relatieve luchtvochtigheid: | 0 - 95 procent |
Frequentie: | 60 Hz |
Modem (RJ-11) poort: | 1 |
Efficientie: | 95 procent |
(Buitenste) hoofdverpakking hoogte: | 238.8 mm |
(Buitenste) hoofdverpakking breedte: | 419.1 mm |
(Buitenste) hoofdverpakking brutogewicht: | 10700 g |
(Buitenste) hoofdverpakking lengte: | 332.7 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 4 stuk(s) |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: | 10037332161304 |
Surge energy rating: | 420 J |
Aantal AC uitgangen: | 8 AC-uitgang(en) |
Nominale input voltage: | 120 V |
Stopcontacttypes: | NEMA 5–15R |
Stroom (max.): | 15 A |
Output power capacity: | 0.65 kVA |
UPS-topologie: | Stand-by (Offline) |
Typische backup tijd op halve lading: | 10 min |
Typische backup tijd op volledige lading: | 3 min |
Netspanning, in bedrijf: | 120 V |
EMI/RFI geluidsfiltering: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite ECO650LCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
2 December 2024
2 December 2024
2 December 2024
2 December 2024