GRAPHITE
DIGITAL PASSIVE INFRARED DETECTOR
graphite_en 01/15
The GRAPHITE detector allows detection of motion in the protected area. This manual applies to the detector
with electronics version H (or newer).
1. Features
Dual element pyrosensor.
Digital motion detection algorithm.
Digital temperature compensation.
Adjustable detection sensitivity.
Built-in EOL resistors.
LED to indicate alarm status.
Remote LED enable/disable.
Alarm memory.
Supervision of detector signal path and supply voltage.
Tamper protection against cover removal.
2. Specifications
Supply voltage ...................................................................................................................................12 V DC ±15%
Standby current consumption......................................................................................................................... 12 mA
Maximum current consumption ...................................................................................................................... 14 mA
EOL resistors ............................................................................................................................................ 2 x 1.1 k
Relay contacts rati .....40 mA / 16 V DC ng (resistive load).........................................................................................
Detectable speed......................................................................................................................................0.3...3 m/s
Alarm signaling period .......................................................................................................................................... 2 s
Warm-up period.................................................................................................................................................. 30 s
Recommended installation height ....................................................................................................................2.4 m
Security grade according to EN50131-2-2 ...................................................................................................Grade 2
Standards complied with ........................................................ EN50131-1, EN50131-2-2, EN50130-4, EN50130-5
Environmental class according to EN50130-5 ........................................................................................................II
Operating temperature range ................................................................................................................ -30...+55 °C
Maximum humidity..........................................................................................................................................93±3%
Dimensions ..................................................................................................................................... 63 x 96 x 49 mm
Weight.................................................................................................................................................................94 g
3. Description
After motion is sensed by the detector y contacts will open for 2 seconds. in the coverage area, the alarm rela
Supervision features
In the event of the voltage drop below 9 V (± 5%) for more than 2 seconds or the signal path failure, the detector
will signal a trouble. The trouble is indicated by the activation of alarm relay and the steady light of LED
indicator. The trouble signaling will continue as long as the trouble persists.
Remote LED enable/disable
The LED can be enabled/disabled remotely, if the LED has not been enabled using the LED ON/OFF pins. The
LED terminal is provided to allow remote LED enable/disable. The LED is enabled, when the terminal is
connected to the common ground, and disabled, when the terminal is disconnected from the common ground.
2 GRAPHITE SATEL
You can connect to the LED terminal an OC type control panel output programmed e.g. as the SERVICE MODE
STATUS, . BI SWITCH or ZONE TEST STATUS
Alarm memory
If the LED is enabled, the detector can indicate the alarm memory. The MEM terminal is provided to allow the
alarm memory feature enable/disable. The feature is enabled, when the terminal is connected to the common
ground. The feature is disabled, when the terminal is disconnected from the common ground. If the alarm
memory feature is enabled and an alarm occurs, the LED will start blinking. Indication of the alarm memory will
continue until the alarm memory feature is enabled again (the MEM terminal is connected to the common
ground). Disabling the alarm memory feature will not stop the alarm memory indication. You can connect to the
MEM terminal an OC type control panel output programmed e.g. as the ARMED STATUS.
4. Electronics board
terminals:
NC - alarm output (NC relay).
TMP - tamper output (NC).
COM - common ground.
12V - power input.
LED - remote LED control.
MEM - alarm memory control.
configuration pins for detector outputs:
the built-in resistors are to be used place the jumpers as shown in Fig. 2 (connect the outputs as shown
in Fig. 10),
the built-in resistors are not to be used place the jumpers as shown in Fig. 3 (connect the outputs as
shown in Fig. 9).
tamper switch.
scale for positioning of pyroelectric sensor against the lens (see: Fig. 8).
fixing screw hole.
red color LED to indicate:
alarm – ON for 2 seconds,
alarm memory – blinking rapidly,
trouble – ON,
warm-up – blinking slowly.
LED enable/disable pins. The LED is enabled, if the jumper is placed over the pins (the pins are shorted).
dual element pyrosensor. Do not touch the pyroelectric sensor, so as not to soil it.
potentiometer for sensitivity adjustment.
SATEL GRAPHITE 3
5. Installation
Disconnect power before making any electrical connections.
1. Remove the front cover (Fig. 4).
2. Remove the electronics board.
3. Make the openings for screws and cable in the enclosure base.


Product specificaties

Merk: Satel
Categorie: Bewegingsdetector
Model: Graphite
Kleur van het product: Wit
Gewicht: 94 g
Breedte: 63 mm
Diepte: 49 mm
Hoogte: 96 mm
LED-indicatoren: Ja
Plaatsing: Binnen
Connectiviteitstechnologie: Bedraad
Montagewijze: Muur
Type stroombron: DC
Certificering: EN50131-1, EN50131-2-2, EN50130-4, EN50130-5
Type beeldsensor: Passieve infraroodsensor (PIR)
Ingangsspanning: 12 V
Stroomverbruik: 14 mA
Bedrijfstemperatuur (T-T): -30 - 55 °C
Installatie hoogte (max): 2.4 m
Stroom in standby: 12 mA

Heb je hulp nodig?

Als je hulp nodig hebt met Satel Graphite stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsdetector Satel

Handleiding Bewegingsdetector

Nieuwste handleidingen voor Bewegingsdetector

Hager

Hager TYA628C Handleiding

2 December 2024
Hager

Hager EER518 Handleiding

2 December 2024
Hager

Hager EER505 Handleiding

2 December 2024
Hager

Hager EE851 Handleiding

2 December 2024
Hager

Hager TXD505 Handleiding

2 December 2024
Hager

Hager TXC513 Handleiding

2 December 2024
Hager

Hager TXC515 Handleiding

2 December 2024
Hager

Hager TXC518 Handleiding

2 December 2024
Hager

Hager TXD501 Handleiding

2 December 2024
Hager

Hager EER515 Handleiding

2 December 2024