Sani-Lav 524A Handleiding
Lees hieronder de π handleiding in het Nederlandse voor Sani-Lav 524A (10 pagina's) in de categorie Spoelbak. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/10
1
A C O R B AT T E R Y P O WERE D
S I N K W I T H E L E C T R O N I C S E N S O R
Operating Manual for Hands-Free Floor Mount Stainless Steel Sink
AC Models 524A and 524A-0.5
Battery Models 524B and 524B-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 372 Lead-Free Compliant, ASME A112.18.1
2
A C O R B AT T E R Y P O W E R E D
S I N K W I T H E L E C T R O N I C S E N S O R
COLUMBIA SPECIFICATIONS
800.626.2117 columbiasinks.com info@columbiasinks.com
Β©2021 Columbia Products
Parts List
(1) Floor mount sink
(1) Leg assembly set
(6) Nuts, bolts and washers for leg assembly
(4) Nuts and washers for connecting sink to leg assembly
(1) AC or Battery powered sensor faucet assembly
(1) Mixing check valve
(1) Strainer assembly with basket
Installation Instructions
Step 1
1. Attach upper and lower leg support brackets to legs with hardware (provided).
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A.
5. Drill holes as required for mounting hardware. (Hardware not included).
Step 2
1. Install strainer assembly.
2. Install faucets to the sink following the instructions provided with sensor unit.
3. Attach supply tube with elbow to back of faucet.
4. Install mixing check valve and compression fitting to control box of each sensor faucet.
Step 3
1. Secure wash station to floor.
2. Connect waste line to strainer assembly (s).
3. Mount sensor control boxes at desired location on wall.
4. Connect power line from sensor to control box.
5. Attach supply tube from faucet to control box.
6. Connect hot and cold water from the source to mixing check valve (s).
7. Remove aerator from the spout assemblies and flush water system. (see step 7 sensor
installation instructions)
8. Check connections for leaks.
9. Replace aerator onto the spout (s).
Step 4
1. Seal gap between bowl and leg assembly as shown in illustration B.
2. We recommend sealing top of backsplash to wall if applicable as shown in illustration C.
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certiξed under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
Go to for more information on replacement parts and installation videos. columbiasinks.com
Illustration A
Illustration B
Illustration C
3
A C O R B AT T E R Y P O W E R E D
S I N K W I T H E L E C T R O N I C S E N S O R
COLUMBIA SPECIFICATIONS
800.626.2117 columbiasinks.com info@columbiasinks.com
Β©2021 Columbia Products
Hole Conο¬guration
9β (228.6mm)
Front Side
16.75β(424.4mm)
27β (685.8mm)
10.5β (266.7mm)
45ΒΊ
23β (584.2mm)
11.5β
(292.1mm) 11.5β
(292.1mm)
20.5β
(520.7mm)
17β
(431.8mm)
1.5β (38mm)
2β (51mm)
Top
20β (508mm) 20.5β (520.7mm)
2β (51mm)
1.5β (38mm)
.875β (22mm)
dia. hole (1)
11.5β
(292.1mm)
11.5β
(292.1mm)
6β (152.4mm)
10.5β
(266.7mm)
1.5β (38mm)
3.25β (88.55mm)
2β drain hole
mounting holes
9β (228.6mm)
on center
.5β R
(12.7mm)
.5β R (12.7mm)
Floor Mounting Detail
1.5β Leg
Thickness
.75β From
Edge of Leg
to First Hole
.5β dia. Floor
Mounting Holes
9β on Center
7.5β (191mm)
Product specificaties
Merk: | Sani-Lav |
Categorie: | Spoelbak |
Model: | 524A |
Heb je hulp nodig?
Als je hulp nodig hebt met Sani-Lav 524A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Spoelbak Sani-Lav
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
8 Juli 2023
8 Juli 2023
8 Juli 2023
Handleiding Spoelbak
- Spoelbak Bartscher
- Spoelbak Blaupunkt
- Spoelbak Franke
- Spoelbak Hendi
- Spoelbak Hotpoint-Ariston
- Spoelbak Leisure
- Spoelbak Rangemaster
- Spoelbak Saro
- Spoelbak Smeg
- Spoelbak Teka
- Spoelbak Concept
- Spoelbak Blanco
- Spoelbak Caple
- Spoelbak CDA
- Spoelbak Kernau
- Spoelbak Artusi
- Spoelbak Foster
- Spoelbak Nodor
- Spoelbak Elkay
- Spoelbak Gustavsberg
- Spoelbak Schock
- Spoelbak Roca
- Spoelbak Advance Tabco
- Spoelbak Eagle Group
- Spoelbak Fulgor Milano
- Spoelbak Laveo
- Spoelbak Deante
- Spoelbak Tot Mate
- Spoelbak Atosa
- Spoelbak Kuchinox
- Spoelbak Oliveri
- Spoelbak Shaws
- Spoelbak Seima
Nieuwste handleidingen voor Spoelbak
17 December 2024
17 December 2024
16 December 2024
16 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024
6 December 2024