Reboots Go Recovery Boots Handleiding

Reboots Massage apparaat Go Recovery Boots

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Reboots Go Recovery Boots (2 pagina's) in de categorie Massage apparaat. Deze handleiding was nuttig voor 4 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
INCLUDES
Power Output 14 W
Pump Capacity 40 l / min
Weight 1,6 kg
Pressure 30–240 mmHg
Dimensions 22 Γ— 14 Γ— 9 cm
Charger 110–240 V;
50–60 Hz
Charger Voltage DC C12.6V;
2A/ 3A
Time Settings up to 1,5 h
Number of Air 6 chambers
Chambers
Number of Settings 4 programs
Charging Time ca. 130 min
Battery Length ca. 180 min
TECHNISCHE DATEN
Control Unit Charging Cable Multi-Plug Air
Tube Sett
Boots ( M / L / XL ) Operating Instructions
OPERATING INSTRUCTIONS
REBOOTS GO
Keep these operating instructions in a safe place! Do not take apart or burn
this device. Repairs to the control unit may only be carried out by persons au-
thorised by Wellcosan GmbH, or the warranty may be invalidated. If this device
becomes damaged, remove the power cord and turn off the device. Remove the
power cord and turn off this device if it comes in contact with water or other
liquids. Do not use this device in damp areas. Ensure that this device remains in
good condition. Do not allow Reboots Go and the built-in battery in particular to
be shaken or thrown.
Nothing should be placed on top of this device when it is in use. Be sure that the
tubes do not become twisted or kinked when the device is in use. Keep Reboots
Go away from heat sources (direct sunlight, radiators, etc.). Turn this device off
when not in use.
Unplug the power cord when the battery is fully charged or the device is not in
use. Always unplug the device before cleaning. Never press down on or pierce
the built-in battery. Keep Reboots Go away from children and anyone who has
not been informed about their proper use.
The manufacturer or importer declares that this product meets the
requirements of the applicable EC directives and conforms to the key
requirements set therein.
This mark indicates that this device must be disposed of separately
from normal household waste. Please take this device to an electronic
waste facility when you wish to dispose of it.
We provide a 24-month warranty for the control unit. If something goes wrong,
it may be necessary to send in the unit for evaluation. When doing this, please
make sure to package the unit securely to avoid damage during transport. De-
fects resulting from improper packaging are not covered by the warranty. War-
ranty terms: Insofar as a legal obligation to provide warranty exists and with
the exclusion of the right to cancellation or price reduction, a replacement will
be provided at no cost or the manufacturer will have the opportunity to correct
the defect. If the defect persists after multiple attempts to correct the problem,
or the replacement unit is found to be defective from the manufacturer, the
customer has the right to a cancellation or price reduction.
Warranty Exclusion: defects resulting from excessive force, improper use,
violent impacts, or changes and repairs by third parties, such as damages from
incorrectly-sized or shorted circuits, or damage resulting from normal wear and
tear are excluded from warranty. Warranty Requirement: the warranty is only
valid in conjunction with the original product receipt. Keep the product receipt
in a safe place.
If you have any questions or problems with the use of this system, please cont-
act us at +49 (0) 6664-919642 or service@wellcosan.de.
LIABILITY DISCLAIMER
Do not use or ask your doctor before using Reboots Recovery
Tech if you suffer from any of the following: acute heart failure,
heart failure with oedema in the legs, swelling in the legs or feet,
diagnosed or suspected deep vein thrombosis, vein infl ammati-
on and arterial diseases, gangrene, dermatitis, atherosclerosis
or venous circulatory disorders, open or infected wounds and
injuries, pain in the legs, injuries to the skin, acute infl amma-
tions, malignant tumours, pulmonary oedema, high blood
pressure, prolonged thrombophlebitis, diagnosed or suspected
thrombosis, erysipelas, severe uncontrolled hypertension, acute
soft tissue trauma of the extremities, peripheral neuropathy or
lymphatic obstructions. The purpose of Reboots Recovery Tech
is to help you improve your relaxation and well-being.
NOTICE: Reboots Recovery Tech is not a medical device
and should not be used for self-treatment. If you are uncer-
tain, please contact your doctor.
MANUFACTURER: Wellcosan GmbH,
Hauptstraße 27, 36381 Schlüchtern, Germany
Tel.: +49 (0) 66 64 / 91 96 42 | Fax: +49 (0) 66 64 / 91 96 44
service@wellcosan.de | www.wellcosan.de
Β© Wellcosan GmbH 2019
SAFETY WARNING
WARRANTY
1 INSERT
MULTI-PLUG
There are two clips on the side of the
Multi-Plug. The clips must be depres-
sed in order to connect the Mul-
ti-Plug to the device. Once the clips
are depressed, the Multi-Plug can
be inserted. The cable must the re-
moved in the same fashion after use.
2 PUT ON
REBOOTS
It is generally best to pull the boots
as high as you can. Only the tips of
your toes (not the full toes!) should
peek out of the ends. Keep your legs
as horizontal as possible while using
the Reboots, and make sure that the
air tubes do not become kinked.
3
TURN ON THE
CONTROL UNIT
On the right side of the unit, you will
fi nd the power switch. If the device
does not turn on when the switch is
fl ipped, the battery is likely drained.
Use the included charging cable to
recharge the battery.
PROGRAMMES GUIDE   /
Maximum regeneration for maximum performance: in order
to achieve the best results from your recovery programme,
please note the following points:
USE
You can use Reboots both before and after exercising, either
to help with relaxation and prevent soreness or to loosen up
or muscles in advance. The focus of the massage depends on
the programme.
LENGTH AND FREQUENCY OF USE
The optimum length of use after training is between 30 and
50 minutes. Before training, use between 10 and 20 minutes
to loosen up your muscles. There is not set maximum length
or frequency. In general, you may use your Reboots as long as
they feel good. After exercise, it is best to use Reboots on a
mid to high level of pressure. Before exercising, you can use
Reboots at a mid-level pressure. As long as you feel comfor-
table during the massage programme, it is fi ne to use higher
pressure or longer programmes. We recommend moving
slowly between pressure levels in order to fi nd your optimal
setting. More is not always better: the recovery programme
should never be unpleasant or painful.
A
Sample
Sequence
for Programme
C
1
2
3
4
B
USEBEFORE USE
 1
 2
 3
 4
 D
Programme A uses very pre-
cise point-for-point pressure,
and is therefore good for
loosening muscles.
Prolonged pressure in pro-
gramme B prevents backfl ow.
Programme B is intended pri-
marily to aid in the removal of
lactic acid. If you are a beginner,
it is best to use programme A
for a while fi rst, before slowly
introducing programme B.
In programme C, several air
chambers are continually
pumped up at once, so that
backfl ow is reduced. This
programme is suitable for
lactic acid removal and is less
intensive than programme
B because the feet are not
continually pressed.
Programme D supplements pro-
gramme C with a very effecti-
ve pulse effect. The pressure in
the last active chamber is raised
three times and then reduced
again. This allows time for meta-
bolic waste to move through the
tissue. The result is a particularly
thorough recovery programme.
C
  1
  3
  2
  4
  5
4SELECT LENGTH The default massage time is 30 min.
You can use the buttons to shorten or lengthen the
programme one minute at a time. The maximum length is 99
minutes. The pump turns off automatically once the program-
me has ended.
5SELECT PRESSURE The default pressure is Level 8.
You can use the buttons to choose between 16
pressure levels.
6
S E L E C T P R O G R A M M E Programme A is selected as the
default. The programme cannot be changed while it is
running. In order to change the programme, you must pause
the device.
7
D E A C T I V A T E C H A M B E R S All compression chambers
are active by default. If you would like to exclude certain
chambers from the massage, you can do that in this step.
8START When you turn on the device, it will be in pause
mode (orange light). Push the start button to begin the
recovery massage. Tip: the device can be used with a drained
battery as long as it is plugged in.
A B C D
2 3 4 5 61
FOOT ο‚„  WAIST
TIME
min
PRES S URE
 4
 5
 6
 7
 8


Product specificaties

Merk: Reboots
Categorie: Massage apparaat
Model: Go Recovery Boots

Heb je hulp nodig?

Als je hulp nodig hebt met Reboots Go Recovery Boots stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Massage apparaat Reboots

Handleiding Massage apparaat

Nieuwste handleidingen voor Massage apparaat