Queenaire QT Thunder QTT3F Handleiding

Queenaire Luchtreiniger QT Thunder QTT3F

Lees hieronder de 📖 handleiding in het Nederlandse voor Queenaire QT Thunder QTT3F (2 pagina's) in de categorie Luchtreiniger. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
QUEENAIRE TECHNOLOGIES, INC.
“The Ozone Specialists”
Queenaire Technologies, Inc.
P.O. Box 133
Ashburn, VA 20146
Toll Free: 1-877-64 OZONE
Tel: 1-703-654-0385 Fax: 1-703-654-0386
Volume
1
Owners Manual
QT Thunder
Troubleshooting Guide
If you are having problems with your ozone machine please refer to the following instructions:
1. The fan comes on, but the green light does not. Remove the top
cabinet from the unit and check the condition of the ceramic plate.
Replace if broken. Replace top cabinet. Remove and replace the .125
milliamp fuse in the back of the unit. If the green indicator light is still
out contact your distributor.
2. When you turn the unit on nothing happens. First check your power
source to ensure there is power to the outlet. Plug the unit in. Check
the fuse marked 2 amp on the back of the unit. Replace if blown. If
the unit still does not operate contact your distributor.
3. If for any reason you are not happy with the performance of this unit contact customer service at
1-877-64 OZONE.
Operating QT Thunder
Following are basic guidelines for eliminating a variety of troublesome odors in rooms up to 1000
square feet.
or complete odor control you must ensure that all areas to be deodorized are exposed. Be
sure to close your draperies, fully exposing all material, open interior doors and turn on
your air handling system. Keep in mind that ozone is a surface agent and must make
contact with the source of the odors to insure complete deodorization.
Deodorizing Hotel Guestrooms
The housekeeper should always clean the guestroom before using the QT Thunder unit and vacate
the room while the unit is in operation. The amount of time needed to completely eliminate the
odor will depend greatly on the size of the room and the severity of the odor problem. Daily
treatment with the QT Thunder unit will decrease the time needed for each treatment and ensure an
odor free room on a daily basis.
The unit should always be placed high on a table or dresser to ensure adequate distribution of the
ozone. Turning on the air handling system will also help to distribute the ozone and eliminate
odors inside the air handler. The unit should then be plugged into a standard wall socket. You
should then set the timer using the following settings as a guideline:
3 - (18 minutes) - For a standard room up to 300 square feet with light odors
5 - (30 minutes) - For medium odors or larger suites up to 1000 square feet
8 - (48 minutes) - For 300 - 1000 square foot rooms with heavy odors
10 - (60 minutes) -For converting smoking rooms to non-smoking/severe mold and mildew
odors
Once the timer is set, turn on the unit and leave the room. For daily treatment, the housekeeper
would continue this procedure with the unit following her from room to room. For severe odors, it
may be necessary to repeat the treatment in 24 hours.
How Does QT Thunder Eliminate Odors?
All Queenaire Technologies, Inc. units eliminate odors by producing a controlled level of ozone.
Ozone is created naturally in our environment by lightning and the suns ultraviolet rays. It is best
known for its benet in the stratosphere for protecting us from the suns rays. What you may not
know is that it is also that fresh smell you experience after a lightning storm. Ozone is Mother
Nature’s solution to outdoor odor problems. QT Thunder incorporates a technology that duplicates
the eect of lightning and creates ozone indoors. The end result is the same, a fresh, odor free
environment.
QT Thunder Maintenance Instructions
The life expectancy of your QT Thunder unit is 10 - 15 years, provided it is serviced and main-
tained on a regular basis. It is recommended that you perform a simple cleaning and maintenance
of your unit every 6 months. Maintenance kits are available through your distributor.
Before you begin performing any work to your ozone unit, be sure to unplug the electrical cord.
Step 1.) Remove two screws on the top of the unit as well as the top two screws on each side of the
unit. Remove the top cover from the unit.
Step 2.) Carefully remove the white ceramic generator plate from its frame. The plate should lift
easily by pulling from the top straight up and out of the frame. Use an alcohol wipe to gently wipe
the plate free of any dirt or stains. Inspect the plate carefully for cracks, breaks or irremovable
stains. The plate can be reused provided there are no breaks or stains.
Step 3.) Use the same alcohol wipe to wipe out the exposed areas inside the unit. Spread the
generator frame apart to wipe the inside of the metal plates that make contact with the generator
plate. Be sure to also wipe the base of the frame completely.
Step 4.) Once the ceramic plate is completely dry, reinsert the plate into the generator frame or
replace the existing plate with a new one.
Step 5.) Reattach the top cover to the unit and put screws back in place.
Step 6.) Remove and discard the green lter on the back of the machine and replace with new
filter.
Step 7.) You may at this point have to change your 125mA fuse. To test your fuse, simply turn the
unit on. If the green ozone light comes on you have completed maintenance of the unit and are
ready to put it back in service. If the light does not come on, locate the 125mA fuse holder on the
back of the unit and remove the holder with a at head screwdriver by turning the holder 1/4 turn.
Remove the blown fuse and replace. Your unit should now be ready to go back to work.
F


Product specificaties

Merk: Queenaire
Categorie: Luchtreiniger
Model: QT Thunder QTT3F

Heb je hulp nodig?

Als je hulp nodig hebt met Queenaire QT Thunder QTT3F stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtreiniger Queenaire

Handleiding Luchtreiniger

Nieuwste handleidingen voor Luchtreiniger